4. Remove the downstream thrust washer from the shaft. Note that the slot faces the
5. Gently slide the rotor from the bearing shaft. Note the orientation of the rotor.
6. Remove the shaft sleeve from the bearing shaft.
7. Remove the upstream thrust washer. Note that the slot faces the rotor.
Figure 9-19: Diffuser cap and Belleville washers removal
rotor.
Figure 9-20: Downstream thrust washer
Important
Handle the rotor with care. Improper handling of the rotor assembly may cause
distortion to the rotor blades thereby affecting meter performance.
Figure 9-21: Rotor removal
Figure 9-22: Shaft sleeve removal
Disassembly is complete.