Planned maintenance
SERIES 1200 LIQUID TURBINE METER
September 2020
Tungsten carbide bearing internals disassembly
Procedure
1. Lay the support fins aside and remove the cotter pin from the castle nut after
2. Remove the castle nut from the shaft.
3. Remove the outlet diffuser cap and Belleville washers.
66
www.Daniel.com
76
Figure 9-16: Bearing assembly retaining rings removal
removing the internals from the flow tube.
Figure 9-17: Cotter pin removal
Figure 9-18: Castle nut removal