DANIEL 1200 Series User Manual page 44

Liquid turbine meter
Table of Contents

Advertisement

SERIES 1200 LIQUID TURBINE METER
User manual
P/N 3-9008-513
Table 4-3: Preamplifier power requirements
Power requirement
type
4.3.5
Grounding
Ground the turbine meter electronics internally for safe operation. Connect a wire to the
chassis ground lug located inside the LME as the primary ground. A secondary ground is
located outside of the LME. Refer to
never be connected to chassis ground.
Figure 4-4: External ground lug
A. External ground lug
44
www.Daniel.com
(continued)
Description
Outputs
Powered pulse output:
Type: Square wave
Frequency range: 0 to 5 kHz
Amplitude: 0 to 5 V
1000 Ohm internal pull-ups, 20 mA, max.
Variable voltage output:
Type: Square wave
Frequency range: 0 to 5 kHz
Amplitude: 0 to Supply voltage
1000 Ohm internal pull-ups, 70 mA, max.
Figure 4-4
and
Prepare the turbine meter for use
September 2020
Figure
4-5. Digital grounds should