REMEHA Quinta 45 Technical Information page 26

Table of Contents

Advertisement

Fan speed at part load (HTG
&
and DHW)
Modulation start point T (F/R)
*
Interface selection (control
(
option)
DHW cut-in T
B
Fan speed at full load (DHW)
C
Intern
D
N/a
E
N/a
F
Forced part load time after start
G
(HTG)
Fan speed at start
H
DHW control stop or boiler
I
modulation set point (based on
parameter #)
DHW control option
J
Variable speed pump
L
HTG cut in Τ
N
N/a
O
Boiler type
P
55979.indd 26
55979.indd 26
Quinta 45/65
10- 60 hundreds
05 - 30 ºC
00 internal
(modulating control only)
01 external interface
10 -05
read 1 - 5 °C
06 read 10 °C
07 read 15 °C
08 read 20 °C
10- 60 hundreds
May not be changed!
00 - 15 minutes
May not be changed!
00 - 30 °C
00 = Three way valve
(port A = HTG,
port B = DHW)
01 = DHW pump
02 = inverted three
way valve
(port A = DHW,
port B = HTG)
n/a
1) (= -10°C)
– 20°C
May not be changed!
26
Remeha
11
12
25
01
05
52
00
)0 (=100)*
25
03
25
20
00
)3
03
10
44
64
2-4-2009 9:42:38
2-4-2009 9:42:38