3.6.3. HS-6085, HS-6110, EH190, EH255 models

The connection of the external dosing electrical signals
takes place on the terminals of A4 and A6 boards, located at
the lower part of the washer electrical box (Fig. 3.17).
If you use dosing signals coming from A-4 and A-6 board,
you must link the COM terminal of each board (X6-1 and X3-
1) by means of an electric insulation conductor of 0.75 mm2
and 400V.
Remove protection cover A of the connection box.
Insert the conductor in Ed and secure it with the fixing
device.
Remove protection cover B of the electric panel.
Pass the conductor through the cable ducting C
Once the conductor connection is done, REPLACE
LOCK THE COVERS CORRECTLY.
POTENTIAL FREE RELAY CONTACTS
Use of four dosing signals
The dosing signals from 1 to 4 are originated in A4 board.
Connect the common dosing cable to the terminal
identified as COM.
Connect the cables between the washer and the dosing
unit to A4 board in the order indicated in the table in
section 3.6.4. (Figure 3.18).
IMPORTANT
This connection allows for the maximum strength at
each of the 1A outputs.
The dosing signals ARE NOT PROTECTED by the
washer fuses.