Qlogic Gem359 Scsi Hot-Swap Controller - MAXDATA PLATINUM 9000-4R Product Manual

Table of Contents

Advertisement

Front panel system diagnostic-interrupt handling
Platform Management Interruption (PMI) / System Diagnostic Interrupt (SDI) status monitor
Event receiver
System interface to the IPMB (via system interface ports)
IPMI Management Controller Initialization Agent (MCIA)
Emergency Management Port (EMP) interface
Serial/modem and LAN alerting
In this platform, the BMC also plays the role of the chassis bridge controller, thus providing integrated
ICMB support. ICMB transports server management information between various chassis in a cluster
configuration that can contain multiple servers and peripherals.

QLogic GEM359 SCSI Hot-swap Controller

The QLogic GEM359 Hot-swap Controller resides on the SCSI backplane board. The primary functions
of the GEM359 are as follows:
Implements the SAF-TE command set
Controls the SCSI Hard Drive fault LEDs
Provides a path for management information via the SCSI
Retrieves hard disk drive fault status, SCSI backplane temperature, and fan failure information
via IPMB
Queries the status of the power distribution board by retrieving information from the BMC
via IPMB
Controls hard disk drive power-on and power-down, facilitating hot-swapping
MAXDATA PLATINUM 90004R Server System
39