4 Hot-swapping System Components

Tools and Supplies Needed

Pen or pencil
Antistatic wrist strap (recommended)

Equipment Log

To record the model and serial numbers of the server, all installed options, and any other pertinent
information about the server, see Appendix B "Equipment Log and Configuration Worksheet" .

Hot-swapping System Fans

The four 120-mm cooling fans are mounted in pairs below the back top cover of the chassis. You can
remove and install these fans without turning the server system power off. Each fan uses an amber
LED to indicate the failed fan. When an LED lights, you need to replace the fan.
!
WARNING
Make sure that the rack is anchored securely so it will not tilt forward when the server chassis is
extended. A crush hazard exists should the rack tilt forward which could cause serious injury.
!
CAUTION
Do not leave the back top cover open or a system fan removed for longer than two minutes; system
cooling is reduced.
1. If the chassis is rack-mounted, slide the chassis out far enough to expose the back top cover
(see warning above).
2. Unlatch the back top cover by pressing the latches (A in Figure 60) and sliding the cover (B in
Figure 60).