General Malfunctions

Malfunction
No connection between
module and terminal
program.
No image on the monitor. Monitor error.
No connection
established, no image
transmission.
No audio transmission to
remote station.
DOC | V4.0 | 2009.06
Possible causes
Incorrect cable connections.
The computer's serial interface
is not connected.
Interface parameters do not
match.
Faulty cable connections.
The module's configuration.
Faulty installation.
Wrong IP address.
Faulty data transmission within
the LAN.
The maximum number of
connections has been reached.
Hardware fault.
Faulty cable connections.
Incorrect configuration.
The audio voice connection is
already in use by another
receiver.
Installation and Operating Manual
VIP X1600 M4S
Recommended solution
Check all cables, plugs,
contacts, terminals and
connections.
Check the other serial interface.
If necessary select a different
interface and make sure that the
computer's interface parameters
match those of the module. Try
the following standard
parameters: 19,200 baud, 8 data
bits, no parity, 1 stop bit. Next,
disconnect the unit from the
power supply and reconnect it
again after a few seconds.
Connect local camera or other
video source to the monitor and
check the monitor function.
Check all cables, plugs, contacts
and connections.
Check all configuration
parameters.
Check all cables, plugs, contacts
and connections.
Check the IP addresses
(terminal program).
Check the data transmission
with ping.
Wait until there is a free
connection and then call the
sender again.
Check that all connected audio
units are operating correctly.
Check all cables, plugs, contacts
and connections.
Check the audio parameters on
the Audio configuration page.
Wait until the connection is free
and then call the sender again.