Bosch VIP X1600 Installation And Operating Manual

Bosch VIP X1600 Installation And Operating Manual

Security systems
Table of Contents

Advertisement

Quick Links

VIP X1600

Advertisement

Table of Contents
loading

Summary of Contents for Bosch VIP X1600

  • Page 1 VIP X1600...
  • Page 2 Copyright This manual is copyrighted material of Bosch Security Systems. All rights reserved. Without express written permission from Bosch Security Systems no portion of this document may be reproduced or transmitted for any reasons, regardless of the means or manner employed, mechanical or electronic.
  • Page 3: Table Of Contents

    General installation conditions ......17 Installing VIP X1600 modules ......18 Installing in a switch cabinet.
  • Page 4 EN | 4 Installation and Operating Manual | VIP X1600 Picture settings........40 MPEG-4 encoder .
  • Page 5 Glossary ......... . 122 Specifications VIP X1600 base ......124 Specifications VIP X1600 module .
  • Page 6 EN | 6 Installation and Operating Manual | VIP X1600 Bosch Security Systems | 2006-03 | V2.0...
  • Page 7: Chapter 1 Preface

    Preface This manual is intended for persons responsible for the installation and operation of the VIP X1600. International, national and where necessary regional electri- cal engineering regulations must be followed at all times. Relevant knowledge of network technology is required. The manual describes the installation and operation of the unit.
  • Page 8: Intended Use

    For exact identification, the model name and serial number are inscribed on the rating plate on the under side of the VIP X1600 base and on the rating plates on the circuit boards of the VIP X1600 modules. Please make a note of this infor- mation before installation if necessary so as to have it to hand in case of ques- tions or when ordering spare parts.
  • Page 9: Chapter 2 Safety Information

    EN | 9 Safety information Electric shock hazard ❚ Never attempt to connect the VIP X1600 to any power network other than the type for which it is intended. ❚ Only use power supply units approved by Bosch Security Systems.
  • Page 10: Installation And Operation

    Any other actions may lead to personal injury, damage to property or damage to the equipment. Maintenance and repair ❚ Never open the housing of a VIP X1600 base. The unit does not contain any user-serviceable parts. Remove only the supplied cover when installing a VIP X1600 module.
  • Page 11: Chapter 3 Product Description

    – Microsoft Virtual Machine – Adobe Acrobat Reader Components supplied for VIP X1600 module ❚ VIP X1600 module ❚ Mounting kit for installation in the VIP X1600 base ❚ Terminal connectors ❚ Quick Installation Guide Bosch Security Systems | 2006-03 | V2.0...
  • Page 12: Requirements For Setup And Configuration

    Installation and Operating Manual | VIP X1600 Requirements for setup and configuration ❚ Installation of a VIP X1600 module in a housing VIP X1600 base ❚ Computer with Windows 2000/XP operating system, access to a network and Microsoft Internet Explorer (version 6.0 or higher) ❚...
  • Page 13: Overview Of Functions

    The use of existing networks means that integration with CCTV systems or local networks can be achieved quickly and easily. The VIP X1600 offers a 2/3 D1 or 2CIF resolution at a complete image rate of 25 (PAL) or 30 (NTSC) images per second for up to 16 channels.
  • Page 14 The UDP and IGMP V2 pro- tocols must be implemented on the network for this function. The VIP X1600 can be used as a digital video recorder for long-term recordings in combination with an iSCSI server. For this, the iSCSI server can be connected directly or via the network.
  • Page 15 ❚ Remote control for all internal functions with TCP/IP ❚ Password protection to prevent unauthorized connection or configuration changes ❚ Local short-term recording for 4 cameras on RAM per VIP X1600 module ❚ Four alarm inputs for external sensors (door contacts, for example) per VIP X1600 module ❚...
  • Page 16: Connections And Displays

    8 RJ45 socket ETH 2 for redundant connection to the network or for direct connection to an iSCSI server 9 LEDs, status information for the VIP X1600 modules and the VIP X1600 base Note For more information about the LEDs see page 117.
  • Page 17: Chapter 4 Installation

    VIP X1600 | Installation and Operating Manual EN | 17 Installation The VIP X1600 modules are solely intended for installing in the VIP X1600 base. Installing the units is a quick and easy operation that does not require any addi- tional tools.
  • Page 18: Installing Vip X1600 Modules

    Caution Do not install a VIP X1600 module in a different housing and do not operate the unit outside of the VIP X1600 base. The ambient temperature during in- stallation must be between 0 and +50 °C (+32 und +122 °F), and the relative humidity must not exceed 80% (non-precipitating).
  • Page 19 EN | 19 Rating plates Every VIP X1600 module has a label on the circuit board containing a printed MAC address by which the module can be uniquely identified. Take note of this MAC address and the location in the VIP X1600 base before installation so that you can later identify the module, even after it has been inserted, for example when performing fault diagnosis.
  • Page 20: Installing In A Switch Cabinet

    EN | 20 Installation and Operating Manual | VIP X1600 Installing in a switch cabinet The VIP X1600 is set up for installing in a 19-inch rack. The necessary installa- tion equipment is contained in the components supplied. Caution When installing in a switch cabinet, ensure that there is sufficient ventila- tion for the unit.
  • Page 21 VIP X1600 | Installation and Operating Manual EN | 21 Installation overview Bosch Security Systems | 2006-03 | V2.0 Installation...
  • Page 22: Connections

    (see Video input, page 46). Data interface The bidirectional data interface of each VIP X1600 module is used to control the connected units, for example a dome camera with motorized lens. The range of controllable equipment is expanding constantly. The manufacturers of the rele- vant equipment can provide specific information on installation and control.
  • Page 23 Connection is via the terminal connector. See page 118 for the pin assignment. Audio connections The audio versions of the VIP X1600 modules contain two line inputs for a total of four mono inputs, which are automatically assigned to the four camera inputs.
  • Page 24 ETH 2 socket. Direct iSCSI connection You can connect the VIP X1600 directly to an iSCSI server via the ETH 2 inter- face. This connection is an alternative to using the second Ethernet interface as a redundant network connection. Use a UTP category 5 crossed patch cable with RJ45 plugs for a direct connection to an iSCSI server.
  • Page 25: Power On/Power Off

    EN | 25 Power on/Power off Power supply The VIP X1600 does not have a power switch. Power is provided once one or two power supply units have been installed. Note Information as to the selection of an appropriate power supply unit can be obtained from your supplier or directly from Bosch Security Systems.
  • Page 26: Setup Using The Configuration Manager

    The Configuration Manager program can be found on the product CD which is part of the VIP X1600 base's scope of delivery. This program allows you to implement and set up new video servers in the network quickly and conve- niently.
  • Page 27 VIP X1600 | Installation and Operating Manual EN | 27 – You can start the configuration if a VIP X1600 module is shown in the list in the left section of the window. To do this, click the entry for the module.
  • Page 28 EN | 28 Installation and Operating Manual | VIP X1600 Installation Bosch Security Systems | 2006-03 | V2.0...
  • Page 29: Chapter 5 Configuration Using A Web Browser

    Configuration using a Web Browser Connecting The integrated HTTP server in every VIP X1600 module provides you with the option to configure the unit over the network with a Web browser. This option is an alternative to configuration using the Configuration Manager program and is considerably richer in function and more convenient than configuration using the terminal program.
  • Page 30 – Follow the on-screen instructions. Establishing the connection At least the VIP X1600 module in slot 1 must have a valid IP address assigned to operate the VIP X1600 in your network. The following default address is preset at the factory for all modules: 192.168.0.1...
  • Page 31: Configuration Menu

    The settings in the configuration menu should only be processed or modified by expert users or system support personnel. All settings are stored in the memory of the VIP X1600 module so that they are retained even in the event of a power failure.
  • Page 32 EN | 32 Installation and Operating Manual | VIP X1600 Start configuration Click the SETTINGS link in the upper section of the window. The Web browser opens a new page with the configuration menu. Navigation – Click one of the menu items in the left window margin. The corresponding submenu is expanded.
  • Page 33 VIP X1600 | Installation and Operating Manual EN | 33 Making changes Each configuration screen shows the current settings. You can change the set- tings by entering new values or by selecting a predefined value from a list field. – After each change, click Set to save the change.
  • Page 34: Unit Identification

    Enter a name that makes it as easy as possible to quickly identify the location. Unit ID: Every VIP X1600 module should be assigned a unique identifier that you enter here as an additional means of identification. Password A VIP X1600 module is generally protected by a password to prevent unautho- rized access to the unit.
  • Page 35 The service user name is the highest authorization level. After entering the cor- rect password, you can access all the functions of the VIP X1600 module and change all configuration settings. The user user name is the middle authorization level. You use it to operate the unit and also to control cameras, but you cannot change the configuration.
  • Page 36: Language

    - it is automatically added. – Enter the current time or click the Synchr. PC button to apply the system time from your computer to the VIP X1600 module. Configuration using a Web Browser...
  • Page 37: Time Server

    The VIP X1600 module in slot 1 is the default time server for the modules in slot 2 to slot 4. In this case, the field Time server IP address can be empty for slot 2 to slot 4 (0.0.0.0).
  • Page 38: Camera Names

    EN | 38 Installation and Operating Manual | VIP X1600 Camera names The camera name makes it easier to identify the remote camera location, in the event of an alarm for example. It will be displayed in the video screen if config- ured to do so (see page 39).
  • Page 39 VIP X1600 | Installation and Operating Manual EN | 39 Camera name stamping: This field sets the position of the camera name overlay. It can be displayed at the Top, at the Bottom or at a position of your choice that you can then specify using the Custom option.
  • Page 40: Picture Settings

    EN | 40 Installation and Operating Manual | VIP X1600 Picture settings You can set the video image of each camera to suit your requirements. The cur- rent video image is displayed in the small window next to the slide controls as confirmation.
  • Page 41: Mpeg-4 Encoder

    You can adapt the MPEG-4 data transmission to the operating environment (for example network structure, bandwidth, data load). To this end, the VIP X1600 module simultaneously generates two data streams (Dual Stream- ing) for each video input, which compression settings you can select individually, for example one setting for transmissions to the Internet and one for LAN con- nections.
  • Page 42 EN | 42 Installation and Operating Manual | VIP X1600 ❚ Profile 4: DSL For DSL connections at 500 kBit/s, resolution 352 × 288/240 pixels ❚ Profile 5: ISDN (2B) For ISDN connections via two B channels, resolution 352 × 288/240 pixels ❚...
  • Page 43 VIP X1600 | Installation and Operating Manual EN | 43 Profile configuration You can change individual parameter values within a profile and the name. You can switch between profiles by clicking the appropriate tabs. Caution The profiles are rather complex. They include a large number of parame- ters that interact with one another, so it is generally best to use the default profiles.
  • Page 44 Installation and Operating Manual | VIP X1600 Target data rate: You can limit the data rate for the VIP X1600 module to optimize utilization of the bandwidth in your network. The target data rate should be set according to the desired picture quality for typical scenes with no excessive motion.
  • Page 45 VIP X1600 | Installation and Operating Manual EN | 45 I-frame distance: This parameter allows you to set the intervals in which the I-frames will be coded. 0 means auto mode, whereby the video server inserts I-frames when necessary. An entry of 1 indicates that I-frames are continuously generated.
  • Page 46: Video Input

    Video input You can activate the 75 Ohm terminating resistor for each video input on the VIP X1600 module. To loop the video signal through, the terminating resistor must be deactivated. Every video input is closed at the time of delivery.
  • Page 47: Audio Settings

    VIP X1600 | Installation and Operating Manual EN | 47 Audio settings You can set the gain of the audio signals to suit your specific requirements. The associated video image is shown in the small window next to the slide con- trols to help you check the audio source and improve assignments.
  • Page 48: Jpeg Posting

    EN | 48 Installation and Operating Manual | VIP X1600 JPEG posting You can save individual JPEG images on an FTP server at certain intervals. You can then retrieve these images at a later date to reconstruct alarm events if required.
  • Page 49 VIP X1600 | Installation and Operating Manual EN | 49 JPEG posting interval: Enter the interval in seconds at which the images will be sent to an FTP server. Enter zero if you do not want any images to be sent.
  • Page 50: Storage Medium

    Installation and Operating Manual | VIP X1600 Storage medium You can record the images from the cameras connected to the VIP X1600 mod- ule in the RAM memory of the unit or in an appropriately configured iSCSI stor- age device.
  • Page 51 VIP X1600 | Installation and Operating Manual EN | 51 Storage information The status of the currently selected storage medium and the data throughput are displayed here for information. You cannot change any of these settings. – Click Advanced to view a status report with logged actions. A new window will open.
  • Page 52: Iscsi Settings

    EN | 52 Installation and Operating Manual | VIP X1600 iSCSI settings If you select type iSCSI server as the storage medium, you then need to set up a connection to the desired iSCSI storage device and set the configuration parameters.
  • Page 53 In this case you should ensure that the entries corre- spond exactly with the configuration of the iSCSI device. – After entering all the settings in the relevant fields, click Set. The VIP X1600 module attempts to create a connection to the required drive using this data.
  • Page 54 EN | 54 Installation and Operating Manual | VIP X1600 Initiator name: The initiator name is automatically displayed after a connection has been estab- lished. Initiator extension: Enter the initiator extension. For the sake of clarity, you can enter a name or the existing extension with a comment, for example "–...
  • Page 55: Partitioning

    Four partitions can be set up for recordings of the cameras connected to the VIP X1600 module, in a similar manner to the partitioning often found on com- puter hard drives. Parameters such as size, quality and type of video recording or compression standard used can be specified for each partition.
  • Page 56 EN | 56 Installation and Operating Manual | VIP X1600 Creating a partition Caution Modifications to the size or number of partitions lead to the entire hard drive being reorganized and the loss of all sequences stored on the drive.
  • Page 57 VIP X1600 | Installation and Operating Manual EN | 57 – Click the Create partition button to start the assistant for creating partitions. The first window appears. – You should always first read the information text in the upper section of the window.
  • Page 58 EN | 58 Installation and Operating Manual | VIP X1600 Caution All modifications to settings are only effective if you complete the configu- ration in the last window by clicking Finish. – Switch to the last window if necessary. – Click Finish to complete the configuration. All settings are now transferred to the unit and subsequently become effective.
  • Page 59 VIP X1600 | Installation and Operating Manual EN | 59 You can perform the required modifications in the Partition properties window. – In the list, click the partition that you want to modify in order to select this par- tition.
  • Page 60: Recording Scheduler

    EN | 60 Installation and Operating Manual | VIP X1600 Recording scheduler Set all parameters for recording. Recording can be performed continuously or in the case of an alarm. Partition: Select the partition in which you want to record. The recording is performed for every video input in the respective partition.
  • Page 61 VIP X1600 | Installation and Operating Manual EN | 61 – Click the Stop button to deactivate the currently selected partition for record- ing. Recordings that are currently running will be interrupted and the config- uration can be modified. Continuous recording You can specify the times during which continuous recording to the hard drive should take place.
  • Page 62 EN | 62 Installation and Operating Manual | VIP X1600 Alarm recording You can specify the times during which images from the cameras selected should be recorded in the event of an alarm. In a similar manner to continuous recording, separate selection fields are avail- able for each partition, and consequently for each camera input.
  • Page 63 VIP X1600 | Installation and Operating Manual EN | 63 This segment in the partition functions in a similar manner to a ring buffer and is overwritten until an alarm is actually triggered. Recording occurs on the segment only for the duration of the preset post-alarm time and a new segment subse- quently used in the same manner.
  • Page 64 EN | 64 Installation and Operating Manual | VIP X1600 Caution All modifications result in the re-organization of the partition and the loss of all sequences on this partition. Changes to the size of a partition (Total partition size) lead to the entire hard drive being reorganized and the loss of all recordings stored on the drive.
  • Page 65 Note The numbering of the check boxes for the alarm inputs corresponds to the labeling of the alarm inputs on the VIP X1600 module. For the motion and video loss alarm, the numbering corresponds to the labeling of the video inputs.
  • Page 66 EN | 66 Installation and Operating Manual | VIP X1600 Total partition size: This displays how much storage space the partition occupies on the drive. Already Used file tracks are displayed in the graphic next to the parameter. Remaining for recording: This displays the maximum remaining recording time.
  • Page 67: Alarm Sources

    VIP X1600 | Installation and Operating Manual EN | 67 Alarm sources You can configure the potential alarm triggers for the VIP X1600 module (for example the alarm inputs). Alarm input 1: to Alarm input 4: Select the option On to activate the alarm by the corresponding external alarm sensor.
  • Page 68: Alarm Connections

    Installation and Operating Manual | VIP X1600 Alarm connections You can select how the VIP X1600 module responds to an alarm. In the event of an alarm, the unit can automatically connect to a predefined IP address. You can enter up to 10 IP addresses which the VIP X1600 module will contact in order in the event of an alarm, until a connection is made.
  • Page 69 VIP X1600 | Installation and Operating Manual EN | 69 Destination password: If the remote station is password protected, enter the password here. Auto-connect: Select the On option to automatically re-establish a connection to one of the previously specified IP addresses after each re-start, after a connection break- down or after a network failure.
  • Page 70: Video Content Analysis

    Installation and Operating Manual | VIP X1600 Video content analysis The VIP X1600 modules contain an integrated video content analysis (abbrevi- ation: VCA), which can detect and analyze changes in the signal. Such changes can be due to movements in the camera's field of view.
  • Page 71 VIP X1600 | Installation and Operating Manual EN | 71 Analysis: Select the option On to activate the video content analysis. As soon as the video content analysis is activated, metadata are created. Depending on the Analysis type selected and the relevant configuration, addi- tional information overlays the video image in the small window.
  • Page 72 EN | 72 Installation and Operating Manual | VIP X1600 Sensitivity The basic sensitivity of the motion detector can be adjusted for the environmen- tal conditions to which the camera is subject. The sensor reacts to variations in the brightness of the video image. The darker the observation area, the higher the value that must be selected.
  • Page 73 VIP X1600 | Installation and Operating Manual EN | 73 Tamper detection You can reveal the tampering of cameras and video cables by means of various options. Run a series of tests at different times of the day and night to ensure that the video sensor is operating as intended.
  • Page 74 EN | 74 Installation and Operating Manual | VIP X1600 Scene too bright Activate this function if tampering associated with exposure to extreme light (for instance, shining a flashlight directly on the objective) should trigger an alarm. The average brightness of the scene provides a basis for recognition.
  • Page 75 VIP X1600 | Installation and Operating Manual EN | 75 Selecting the area You can select the image areas in the reference image that are to be monitored. The video image is subdivided into 858 square fields. You can activate or deac- tivate each of these fields individually.
  • Page 76: Alarm E-Mail

    As an alternative to automatic connecting, alarm states can also be documented by e-mail. In this way it is possible to notify a recipient who does not have a video receiver. In this case the VIP X1600 module automatically sends an e-mail to a previously defined e-mail address.
  • Page 77 VIP X1600 | Installation and Operating Manual EN | 77 Caution When a cellphone is used as the receiver, make sure to activate the e-mail or SMS function, depending on the format, so that these messages can be received. You can obtain information on operating your cellphone from your cellphone provider.
  • Page 78: Relay

    EN | 78 Installation and Operating Manual | VIP X1600 Relay You can configure the switching behavior of the relay outputs. For each relay, you can specify an open switch relay (normally closed contact) or a closed switch relay (normally open contact).
  • Page 79 VIP X1600 | Installation and Operating Manual EN | 79 Relay follows: If required, select a specific event that will trigger the relay. The following events are possible triggers: ❚ Off Relay is not triggered by events ❚ Connection Trigger whenever a connection is made ❚...
  • Page 80: Com1

    Note If the VIP X1600 module is working in multicast mode (see page 84), the first remote location to establish a video connection to the unit is also as- signed the transparent data connection. However after about 15 seconds of inactivity the data connection is automatically terminated and another remote location can exchange transparent data with the unit.
  • Page 81 Note If you are using a Bosch AutoDome, remember that the value of the Cam- era ID must always be selected one less than the Bosch camera number (for example: Bosch camera number: 1, Camera ID: 0).
  • Page 82: Network

    EN | 82 Installation and Operating Manual | VIP X1600 Network The settings in this screen are used to integrate the VIP X1600 module into an existing network. Caution Changes to the IP address, subnet mask or gateway address are trans- ferred to the unit by clicking Set.
  • Page 83 80. 1. SNMP host address: / 2. SNMP host address: The VIP X1600 module supports the SNMP (Simple Network Management Pro- tocol) for managing and monitoring network components, and can send SNMP messages to IP addresses. It supports SNMP MIB II and its traps in their full functionality in the unified code.
  • Page 84: Multicasting

    Multicasting In addition to a 1:1 connection between an encoder and a single receiver (uni- cast), the VIP X1600 can enable multiple receivers to receive the video signal from an encoder simultaneously. The device either duplicates the data stream itself and then distributes it to multiple receivers (Multi-unicast) or it sends a sin- gle data stream to the network, where the data stream is simultaneously distrib- uted to multiple receivers in a defined group (Multicast).
  • Page 85 (duplication of the data streams in the network). With the setting 0.0.0.0 the encoder for the relevant stream operates in multi-uni- cast mode (copying of data streams in the unit). The VIP X1600 module sup- ports multi-unicast connections for up to five simultaneously connected receiv- ers.
  • Page 86: Version Information

    Keep a record of these numbers in case technical assistance is required. Hardware version: The hardware version number of the VIP X1600 module is displayed. Firmware version: The firmware version number of the VIP X1600 module is displayed.
  • Page 87: Livepage Configuration

    VIP X1600 | Installation and Operating Manual EN | 87 Livepage configuration In this window you can customize the appearance of the LIVEPAGE to suit your requirements. You can opt to have selected information and controls displayed in addition to the video image.
  • Page 88 EN | 88 Installation and Operating Manual | VIP X1600 URL for logo: Enter the path to a suitable graphic if you want to replace the manufacturer's logo. The image file can be stored on a local computer, in the local network or at an Internet address.
  • Page 89 VIP X1600 | Installation and Operating Manual EN | 89 Show system log: The system messages are displayed along with the date and time in a field next to the video image and provide information about the establishment and termi- nation of connections, etc.
  • Page 90: Power Supply/Fans

    This page is only visible for a VIP X1600 module in slot 1. Check power redundancy: Select the option On if the VIP X1600 is to be supplied by two power supply units. This selection is important for displaying the power supply status mes- sages correctly.
  • Page 91: Firmware And Configuration Upload

    It will then be automatically installed there. In this way, a VIP X1600 module can be serviced and updated remotely without a technician having to change the installation on site. You obtain the current firmware from your customer service or from the down- load area on our Internet site.
  • Page 92 EN | 92 Installation and Operating Manual | VIP X1600 If the LED of the corresponding VIP X1600 module on the front side of the VIP X1600 is showing red, the upload has failed and you need to repeat the upload.
  • Page 93: Function Test

    The VIP X1600 offers a variety of configuration options. You should therefore check that it is functioning correctly after installation and configuration. The function test is the only way to ensure that the VIP X1600 operates as expected in the event of an alarm.
  • Page 94 EN | 94 Installation and Operating Manual | VIP X1600 Configuration using a Web Browser Bosch Security Systems | 2006-03 | V2.0...
  • Page 95: Chapter 6 Operation

    VIP X1600 | Installation and Operating Manual EN | 95 Operation Operation with Microsoft Internet Explorer A computer with Microsoft Internet Explorer (version 6.0 or higher) can receive live images from the unit, control cameras or other peripherals and replay saved video sequences.
  • Page 96 EN | 96 Installation and Operating Manual | VIP X1600 Establishing the connection Any VIP X1600 module must be assigned a valid IP address to operate on your network. The following default address is preset at the factory: 192.168.0.1 – Start the Web browser.
  • Page 97: The Livepage

    Note The VIP X1600 modules offer the option to limit the extent of access using various authorization levels (see page 34). – Enter the user name and associated password in the corresponding text fields.
  • Page 98 EN | 98 Installation and Operating Manual | VIP X1600 Image selection You can view the image from each camera individually on a full screen. – Click one of the tabs Camera 1 ... Camera 4 above the video image to view the corresponding camera image.
  • Page 99 Active high = icon lit green, Active low = icon not lit. Trigger relay You can switch connected units by means of the relays in the VIP X1600 mod- ules (for example lights or door openers).
  • Page 100 EN | 100 Installation and Operating Manual | VIP X1600 Audio function Depending on the configuration, audio data can be transmitted from the unit. All users who are connected by browsers receive the audio signals sent by the unit. Note It is not possible to send audio signals to the unit.
  • Page 101: Saving Snapshots

    VIP X1600 | Installation and Operating Manual EN | 101 Saving snapshots You can save individual images from the video sequence(s) currently shown on the LIVEPAGE in JPEG format on your computer's hard drive. You can save snapshots from each of the four cameras in the Quad video view.
  • Page 102: Running Recording Program

    Installation and Operating Manual | VIP X1600 Installing MPEG viewer You can play back saved video sequences using the MPEG viewer from Bosch Security Systems which can be found on the product CD supplied (see Components supplied, page 11). Note Suitable MPEG ActiveX software must be installed on the computer in or- der to play back saved video sequences using the MPEG viewer.
  • Page 103: The Recordings Page

    VIP X1600 | Installation and Operating Manual EN | 103 The RECORDINGS page You can access the RECORDINGS page for playing back recorded video sequences from the LIVEPAGE as well as from the SETTINGS menu. The RECORDINGS link is only visible if a storage medium has been selected (see page 50).
  • Page 104 EN | 104 Installation and Operating Manual | VIP X1600 Selecting recordings In the left section of the page, first select the partition whose recordings you want to view. All sequences that are saved in the partition are displayed in the list. A running number (track) is assigned to each sequence.
  • Page 105 VIP X1600 | Installation and Operating Manual EN | 105 – If required, drag the green arrow to the point in time at which the playback should begin. Alternatively you can double-click directly in the gray time inter- val or in the timescale to jump to the position selected in this manner.
  • Page 106 EN | 106 Installation and Operating Manual | VIP X1600 In addition, you can set markers in the sequences, so-called bookmarks, and jump directly to these. These bookmarks are indicated as small yellow arrows above the time interval. Use the bookmarks as follows:...
  • Page 107: Backup

    VIP X1600 | Installation and Operating Manual EN | 107 Backup You can back up the videosequences or single images stored on the hard drive of the unit to the computer's hard drive. First select the required sequence as described in the previous section. The fol-...
  • Page 108: Installing Mpeg Viewer

    Installation and Operating Manual | VIP X1600 Installing MPEG viewer You can play back saved video sequences using the MPEG viewer from Bosch Security Systems which can be found on the product CD supplied (see Components supplied, page 11). Note Suitable MPEG ActiveX software must be installed on the computer in or- der to play back saved video sequences using the MPEG viewer.
  • Page 109: Hardware Connections Between Video Servers

    EN | 109 Hardware connections between video servers You can easily connect a VIP X1600 with connected cameras as a sender, and a suitable MPEG-4 compatible hardware decoder (for example VIP XD) with a connected monitor as a receiver via an Ethernet network. In this way it is possi- ble to cover long distances without the need for major installation or cabling work.
  • Page 110 EN | 110 Installation and Operating Manual | VIP X1600 Connect on alarm With the appropriate configuration, a connection between a sender and a receiver is made automatically when an alarm is triggered (see page 68). After a short time the live video image from the sender appears on the connected mon- itor.
  • Page 111: Operation With Decoder Software

    VIP X1600 | Installation and Operating Manual EN | 111 Operation with decoder software The video server VIP X1600 provides a highly efficient systems solution together with the VIDOS software. VIDOS is a software package for operating, controlling and managing of CCTV installations (such as surveillance systems) at remote locations.
  • Page 112 EN | 112 Installation and Operating Manual | VIP X1600 Operation Bosch Security Systems | 2006-03 | V2.0...
  • Page 113: Chapter 7 Maintenance And Upgrades

    IP address, subnet mask and gateway address. Restart (Reset) You can initiate a restart of the VIP X1600 module, for example if the module is no longer responding. In this case all settings are maintained. – In the address field of the Web browser, enter /reset after the IP address of the VIP X1600 module (for example 192.168.0.16/reset).
  • Page 114: Repairs

    Transfer and disposal The VIP X1600, the VIP X1600 base and a VIP X1600 module should only be passed on together with this installation and operating manual. Your Bosch product is designed and manufactured with high quality materials and components which can be recycled and reused.
  • Page 115: Chapter 8 Appendix

    Troubleshooting If you cannot resolve a fault, please contact your supplier or system administra- tor or go directly to Bosch Security Systems Customer Service. The version numbers of the internal processors can be viewed on a special page. Make a note of this information before contacting Customer Service.
  • Page 116 EN | 116 Installation and Operating Manual | VIP X1600 Malfunction Possible causes Solution No connection estab- The module's configuration. Check all configuration parame- lished, no image ters. transmission. Faulty installation. Check all cables, plugs, contacts and connections. Wrong IP address.
  • Page 117: Leds

    VIP X1600 | Installation and Operating Manual EN | 117 LEDs The VIP X1600 network video server is equipped with a number of LEDs that show the operating status and can give indications of possible malfunctions. RJ45 sockets 10/100/1000 Base-T Green LED lit up: Network connection exists.
  • Page 118: Terminal Block

    EN | 118 Installation and Operating Manual | VIP X1600 Terminal block The terminal block has several contacts for: ❚ 4 alarm inputs ❚ 4 relay outputs ❚ Serial data transmission Pin assignment (starting at upper left) Contact Function Input alarm 1...
  • Page 119: Communication With Terminal Program

    Communication with terminal program Data terminal In the case where a VIP X1600 module cannot be found in the network or the connection to the network is interrupted, you can connect a data terminal to the VIP X1600 module for implementation and setting of important parameters.
  • Page 120 Installation and Operating Manual | VIP X1600 Command inputs After the connection has been established, you must log on to the VIP X1600 module to access the main menu. Other submenus and functions can be accessed using the on-screen commands.
  • Page 121 You must restart to activate the new IP address, a new subnet mask or a gateway address. Restart Briefly interrupt the power supply to the VIP X1600 for a restart (disconnect the power supply unit from the mains supply and switch on again after a few sec- onds).
  • Page 122: Glossary

    EN | 122 Installation and Operating Manual | VIP X1600 Glossary Brief explanations of some of the terms and abbreviations used in this manual are given below. 10/100/1000 Base-T IEEE-802.3 specification for 10, 100 or 1000 MBit/s Ethernet Address Resolution Protocol: a protocol for mapping MAC and...
  • Page 123 VIP X1600 | Installation and Operating Manual EN | 123 Management Information Base; a collection of information for remote servicing using the SNMP protocol MPEG-4 A further development of MPEG-2 designed for transmitting audiovisual data at very low transfer rates (for example over the...
  • Page 124: Specifications Vip X1600 Base

    Installation and Operating Manual | VIP X1600 Specifications VIP X1600 base Device Operating voltage 12 V DC, redundant Power consumption Maximum 60 W with 4 VIP X1600 modules LAN interface 2 × Ethernet 10/100/1000 Base-T, automatic adjustment, half/full duplex, RJ45 Displays 5 ×...
  • Page 125: Specifications Vip X1600 Module

    VIP X1600 | Installation and Operating Manual EN | 125 Specifications VIP X1600 module Device Operating voltage Supply via housing VIP X1600 base Power consumption Maximum 12 W Data interface 1 × RS232/RS422/RS485, bidirectional terminal plugs Alarm inputs 4 × non-isolated closing contact, terminal plugs, max.
  • Page 126 EN | 126 Installation and Operating Manual | VIP X1600 Protocols/standards Video standards PAL, NTSC Video coding protocols MPEG-4, JPEG Video data rate 9.6 kBit/s ... 6 MBit/s per channel Image resolutions 704 × 576/480 pixels (4CIF/D1) (PAL/NTSC) 704 × 288/240 pixels (2CIF) 464 ×...
  • Page 127 VIP X1600 | Installation and Operating Manual EN | 127 Index Camera name 38 Activate audio function 47 Camera selection 98 Activate partition 60 Cameras 22 Activation key 90 Changes 33 Actuator 23 Changes in light level 71 Alarm 39...
  • Page 128 EN | 128 Installation and Operating Manual | VIP X1600 Default camera 69 Hardware version 86 Defaults 45 Heat 17 Deleting partitions 59 Heat load 17 Deleting recordings 66 Display stamping 38 Identification 8 Dome camera 22 IGMP V2 84...
  • Page 129 VIP X1600 | Installation and Operating Manual EN | 129 Main functions 15 Operation 9 Maintenance 10 Overview of functions 13 Make contact 23 Manufacturer logo 87 Parameters 27 Marker 106 Parity 81 Media playback 103 Partition 55 Memory medium 50...
  • Page 130 EN | 130 Installation and Operating Manual | VIP X1600 Reflections of light 71 Streaming 85 Regulations 7 Subnet mask 82 Relay 78 Symbols 7 Relay output 23 Synchronize 36 Remote control 14 System log 89 Repair 10 System requirements 29...
  • Page 131 VIP X1600 | Installation and Operating Manual EN | 131 Unit ID 34 Unit identification 34 Unit name 34 Unit time 36 URL 30 User name 35 VCA metadata 71 VCR 46 Ventilation 20 Ventilator 90 Version 86 Video content analysis 70...
  • Page 132 EN | 132 Installation and Operating Manual | VIP X1600 Bosch Security Systems | 2006-03 | V2.0...
  • Page 134 Bosch Sicherheitssysteme GmbH Bosch Security Systems B.V. Robert-Koch-Straße 100 P.O. Box 80002 85521 Ottobrunn 5600 JB Eindhoven Germany The Netherlands www.bosch-sicherheitssysteme.de www.boschsecuritysystems.com Copyright © 2006 BOSCH Sicherheitssysteme GmbH Subject to change. Printed in Germany. VIPX1600/0306/en/1...

Table of Contents