You can configure the serial interface parameters (orange terminal block) to meet your
requirements.
NOTICE!
If the module is working in multicast mode (see Section 5.40 Advanced Mode: Multicasting,
i
page 81), the first remote location to establish a video connection to the unit is also assigned
the transparent data connection. However, after about 15 seconds of inactivity the data
connection is automatically terminated and another remote location can exchange
transparent data with the unit.
Serial port function
Select a controllable unit from the list. If you wish to use the serial port to transmit
transparent data, select Transparent. Select Terminal if you wish to operate the unit from a
terminal.
NOTICE!
i
After selecting a unit, the remaining parameters in the window are set automatically and
should not be changed.
Camera ID
If necessary, enter the ID of the peripheral you wish to control (for example a dome camera or
pan/tilt head).
Baud rate
Select the value for the transmission rate in bps.
Data bits
The number of data bits per character cannot be changed.
Stop bits
Select the number of stop bits per character.
Parity check
Select the type of parity check.
Interface mode
Select the desired protocol for the serial interface.
Bosch Security Systems
Installation and Operating Manual