Table of Contents

Advertisement

VIP X1 XF
VIP-X1XF | VIP-X1XF-E
en
Installation and Operating Manual

Advertisement

Table of Contents
loading

Summary of Contents for Bosch VIP-X1XF

  • Page 1 VIP X1 XF VIP-X1XF | VIP-X1XF-E Installation and Operating Manual...
  • Page 3: Table Of Contents

    Overview of functions Connections, controls and displays Installation Preparations Mounting Connections Power on/Power off Setup using Bosch Video Client Configuration using a Web browser Connecting Configuration menu Basic Mode: Device Access Basic Mode: Date/Time Basic Mode: Network Basic Mode: Encoder...
  • Page 4 The RECORDINGS page Hardware connections between video servers 6.10 Operation using software decoders Maintenance and upgrades Testing the network connection Unit reset Repairs Transfer and disposal Appendix Troubleshooting General malfunctions DOC | V4.54 | 2011.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
  • Page 5 Table of Contents | en Malfunctions with iSCSI connections LEDs Processor load Network connection Serial interface Terminal block Communication with terminal program 8.10 Copyrights Specifications Standard version Eco-version Glossary Index Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.54 | 2011.09...
  • Page 6: Preface

    Various functions can be triggered automatically by incorporating external alarm sensors. Other applications are not permitted. In the event of questions concerning the use of the unit which are not answered in this manual, please contact your sales partner or: Bosch Sicherheitssysteme GmbH Werner-von-Siemens-Ring 10 85630 Grasbrunn Germany www.boschsecurity.com...
  • Page 7: Eu Directives

    Please make a note of this information before installation, if necessary, so as to have it to hand in case of questions or when ordering spare parts. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.54 | 2011.09...
  • Page 8: Safety Information

    – If safe operation of the unit cannot be ensured, remove it from service and secure it to prevent unauthorized operation. In such cases, have the unit checked by Bosch Security Systems. Safe operation is no longer possible in the following cases: –...
  • Page 9: Product Description

    Adobe Acrobat Reader NOTICE! Check that the delivery is complete and in perfect condition. Arrange for the unit to be checked by Bosch Security Systems if you find any damage. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.54 | 2011.09...
  • Page 10: System Requirements

    – Microsoft Internet Explorer (version 7.0 or higher) – Receiver software, for example Bosch Video Client (version 1.1 or higher) or Bosch Video Management System (version 3.0 or higher) – H.264 compatible hardware decoder from Bosch Security Systems (for example VIP XD HD) as a receiver and connected video monitor –...
  • Page 11: Overview Of Functions

    HTTPS. You can protect the control channels via the SSL encryption protocol. With an additional license, the user data itself can be encrypted. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.54 | 2011.09...
  • Page 12 LIVEPAGE as well as on the RECORDINGS page. Video sequences can be stored by means of a mouse click and can be redisplayed using the Player program supplied as part of the scope of delivery. DOC | V4.54 | 2011.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
  • Page 13 Flexible encryption of control and data channels – Authentication according to international standard 802.1x – Bidirectional audio (mono) for line connections – Audio encoding to international standards G.711 or L16 Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.54 | 2011.09...
  • Page 14: Connections, Controls And Displays

    Ethernet LAN (local network), 10/100 MBit Base-T NOTICE! For more information about the LEDs, see Section 8.4 LEDs, page 115. For terminal block assignment, see Section 8.8 Terminal block, page 117. DOC | V4.54 | 2011.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
  • Page 15 Ethernet LAN (local network), 10/100 MBit Base-T NOTICE! For more information about the LEDs, see Section 8.4 LEDs, page 115. For terminal block assignment, see Section 8.8 Terminal block, page 117. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.54 | 2011.09...
  • Page 16: Installation

    – Avoid impacts, blows and severe vibrations that exceed the specification limits (see Section 9 Specifications, page 121), as these can irreparably damage the unit. DOC | V4.54 | 2011.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
  • Page 17: Mounting

    Slide the unit into the plastic frame until you feel it lock securely into place. – Finally, check that the unit is securely attached in the installation location. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.54 | 2011.09...
  • Page 18: Connections

    If the card is formatted, all existing data is deleted from the card. You should therefore check whether the SD card contains any data that needs to be backed up before it is inserted. DOC | V4.54 | 2011.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
  • Page 19 200 mA (SELV) may be applied to the relay contacts.  Connect the lines to the appropriate terminals on the orange terminal block (standard version: R1 and R2; Eco-version: R) and check that the connection is secure. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.54 | 2011.09...
  • Page 20: Power On/Power Off

    NOTICE! Using Bosch Video Client to set all parameters in the VIP X1 XF is an alternative to configuration by means of a Web browser, as described in chapter 5 of this manual.
  • Page 21 Follow the instructions given in the Configuration Wizard window. Additional parameters You can check and set additional parameters with the assistance of the Configuration Manager application in Bosch Video Client. You can find detailed information on this in the documentation for these applications. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.54 | 2011.09...
  • Page 22: Configuration Using A Web Browser

    Insert the product CD into the computer's CD-ROM drive. If the CD does not start automatically, open the root directory of the CD in Windows Explorer and double-click MPEGAx.exe. Follow the on-screen instructions. DOC | V4.54 | 2011.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
  • Page 23 If you do not connect, the unit may have reached its maximum number of connections. Depending on the unit and network configuration, each VIP X1 XF can have up to 25 Web browser connections or up to 50 connections via Bosch Video Client or Bosch Video Management System.
  • Page 24: Configuration Menu

    The exception is the time settings, which are lost after 72 hours without power if no central time server is selected (see Section 5.4 Basic Mode: Date/Time, page 28). DOC | V4.54 | 2011.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
  • Page 25 CAUTION! Save each change with the associated Set button. Clicking the Set button saves the settings only in the current field. Changes in any other fields are ignored. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.54 | 2011.09...
  • Page 26: Basic Mode: Device Access

    It will be displayed in the video screen if configured to do so (see Section Camera name stamping, page 38). The camera name makes the task of administering cameras in larger video monitoring systems easier, for example using the Bosch Video Client or Bosch Video Management System programs.
  • Page 27 When assigning passwords, you should therefore always start from the highest authorization level, service, and use different passwords. Confirm password In each case, enter the new password a second time to eliminate typing mistakes. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.54 | 2011.09...
  • Page 28: Basic Mode: Date/Time

    SNTP server as the protocol. This supports a high level of accuracy and is required for special applications and subsequent function extensions. Select Time server for a time server that works with the protocol RFC 868. DOC | V4.54 | 2011.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
  • Page 29: Basic Mode: Network

    IP addresses automatically assigned to the VIP X1 XF. Certain applications (Bosch Video Client, Bosch Video Management System) use the IP address for the unique assignment of the unit. If you use these applications, the DHCP server...
  • Page 30: Basic Mode: Encoder

    For ISDN connections via one B-channel, resolution 352 × 288/240 pixels – MODEM For analog modem connections with 20 kbps, resolution 352 × 288/240 pixels – For GSM connections at 9,600 baud, resolution 352 × 288/240 pixels DOC | V4.54 | 2011.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
  • Page 31: Basic Mode: Audio

    80 kbps per connection in each direction. If you do not want any audio data to be transmitted, select Off. Line In You can set the line input gain. Line Out You can set the line output gain. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.54 | 2011.09...
  • Page 32: Basic Mode: Recording

    You can select all required text on this page with the mouse and copy it to the clipboard with the [Ctrl]+[C] key combination, for example if you want to send it via e-mail. DOC | V4.54 | 2011.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
  • Page 33: Advanced Mode: Identification

    It will be displayed in the video screen if configured to do so (see Section Camera name stamping, page 38). The camera name makes the task of administering cameras in larger video monitoring systems easier, for example using the Bosch Video Client or Bosch Video Management System programs.
  • Page 34 This text is added to the initiator name, separated from it by a full stop. You can see the initiator name in the system overview (see Section 5.9 Basic Mode: System Overview, page 32). DOC | V4.54 | 2011.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
  • Page 35: Advanced Mode: Password

    Do not use any special characters, for example &, in the password. Special characters are not supported by the system's internal management. Confirm password In each case, enter the new password a second time to eliminate typing mistakes. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.54 | 2011.09...
  • Page 36: Advanced Mode: Date/Time

    Clicking the Delete button will remove the entry from the table. Select other values from the list fields below the table to change the entry. Changes are made immediately. DOC | V4.54 | 2011.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
  • Page 37 SNTP server as the protocol. This supports a high level of accuracy and is required for special applications and subsequent function extensions. Select Time server for a time server that works with the protocol RFC 868. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.54 | 2011.09...
  • Page 38: Advanced Mode: Display Stamping

    If you select the Custom option, additional fields are displayed where you can specify the exact position (Position (XY)). In the Position (XY) fields, enter the values for the desired position. DOC | V4.54 | 2011.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
  • Page 39 Choose On if you wish the transmitted video images to be "watermarked". After activation, all images are marked with an icon. The icon indicates if the sequence (live or saved) has been manipulated (see Section Display stamping, page 97). Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.54 | 2011.09...
  • Page 40: Advanced Mode: Appearance

    If you want to use the original graphics again, simply delete the entries in the Company logo and Device logo fields. JPEG interval You can specify the interval at which the individual images should be generated for the M-JPEG image on the LIVEPAGE. DOC | V4.54 | 2011.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
  • Page 41: Advanced Mode: Livepage Functions

    Bilinx control (standard version only) Next to the field for view control at the top left of the LIVEPAGE, an additional field is displayed for the special Bosch Security Systems Bilinx control. Select the appropriate protocol for the connected camera here.
  • Page 42 Enter the path for the storage location of individual images and video sequences that you can save from the LIVEPAGE. If necessary, click Browse to find a suitable directory. DOC | V4.54 | 2011.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
  • Page 43: Advanced Mode: Logging

    You can then view, edit and print this file with any text editor or the standard Office software. File for system log Enter the path for saving the system log here. If necessary, click Browse to find a suitable directory. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.54 | 2011.09...
  • Page 44: Advanced Mode: Video Input

    PLL as a result of jitter effects caused by the mechanical components of a VCR. NOTICE! In some cases, selecting the VCR option can lead to an improvement in the video image even with a camera connected. DOC | V4.54 | 2011.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
  • Page 45: Advanced Mode: Picture Settings

    The higher the value set with the slide control, the more high-frequency components are filtered from the image. Check your setting in the image window next to the slide controls. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.54 | 2011.09...
  • Page 46 VIP X1 XF Also observe the processor load indicator that appears at the top of the window near the manufacturer's logo (see Section 8.5 Processor load, page 116). DOC | V4.54 | 2011.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
  • Page 47: Advanced Mode: Encoder Profile

    Change the profiles only once you are fully familiar with all the configuration options. In the default setting, Stream 1 is transmitted for alarm connections and automatic connections. Bear this fact in mind when assigning the profile. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.54 | 2011.09...
  • Page 48 IBP as GOP structure only even values are supported. If you have selected IBBP as GOP structure only 3 or multiples of 3 are supported as value. DOC | V4.54 | 2011.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
  • Page 49 With the slide control, define a control range from a chosen value to 51. The encoder delivers the best possible quality within this control range while maintaining the maximum bit rate. Default Click Default to return the profile to the factory default values. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.54 | 2011.09...
  • Page 50: Advanced Mode: Encoder Streams

    Select the required encoder properties and one of the encoder profiles for each data stream. Click the Preview button. The preview screens for both data streams are shown. DOC | V4.54 | 2011.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
  • Page 51 You can select the maximum frame rate for transmitting the JPEG images. Picture quality This setting allows you to define the picture quality. Low quality requires a lower bandwidth in the network. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.54 | 2011.09...
  • Page 52: Advanced Mode: Audio

    Select a format for audio recording. The default value is G.711. Select L16 if you want better audio quality with higher sampling rates. This requires approx. eight times the G.711 bandwith. DOC | V4.54 | 2011.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
  • Page 53: Advanced Mode: Storage Management

    It is also possible to let the VRM Video Recording Manager control all recording when accessing an iSCSI system. This is an external program for configuring recording tasks for video servers. For further information please contact your local customer service at Bosch Security Systems.
  • Page 54 (see Section 5.24 Advanced Mode: Retention Time, page 58). Formatting storage media You can delete all recordings on a storage medium at any time. DOC | V4.54 | 2011.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
  • Page 55: Advanced Mode: Recording Profiles

    Click a storage medium in the Managed storage media list to select it. Click the Remove button below the list. The storage medium is deactivated and removed from the list. 5.23 Advanced Mode: Recording Profiles Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.54 | 2011.09...
  • Page 56 If you select Off, no automatic recording takes place. CAUTION! You can specify limitations for overwriting older recordings in Continuous mode by configuring the retention time (see Section 5.24 Advanced Mode: Retention Time, page 58). DOC | V4.54 | 2011.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
  • Page 57 NOTICE! For more information, please see the Alarm Task Script Language document and the RCP+ documentation. These documents can be found on the product CD supplied. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.54 | 2011.09...
  • Page 58: Advanced Mode: Retention Time

    Recording 1 / Recording 2 Enter the required retention time in hours or days for each recording. 5.25 Advanced Mode: Recording Scheduler DOC | V4.54 | 2011.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
  • Page 59 Click the Select All button to link all time intervals to the selected profile. Click the Clear All button to deselect all of the intervals. When you are finished, click the Set button to save the settings in the unit. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.54 | 2011.09...
  • Page 60: Advanced Mode: Recording Status

    Recording status The graphic indicates the recording activity of the VIP X1 XF. You will see an animated graphic while recording is taking place. 5.26 Advanced Mode: Recording Status DOC | V4.54 | 2011.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
  • Page 61: Advanced Mode: Alarm Connections

    Destination IP address For each number, enter the corresponding IP address for the desired remote station. Destination password If the remote station is password protected, enter the password here. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.54 | 2011.09...
  • Page 62 Bosch Video Client or Bosch Video Management System, you can store a general password here. The VIP X1 XF can use this general password to connect to all remote stations protected with the same password.
  • Page 63 (see Section 5.19 Advanced Mode: Encoder Profile, page 47). Audio Select the On option if you wish to additionally transmit a standalone G.711 encoded audio stream with alarm connections. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.54 | 2011.09...
  • Page 64: Advanced Mode: Vca

    Select a VCA configuration and make the required settings. If necessary, click the Default button to return all settings to their default values. DOC | V4.54 | 2011.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
  • Page 65: Advanced Mode: Vca Profiles

    Click the Load... button to load a saved profile. A new window opens in which you can select the profile file and specify where to save the file. VCA configuration Select one of the profiles here to activate it or edit it. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.54 | 2011.09...
  • Page 66 NOTICE! Additional analysis algorithms with comprehensive functions, such as IVMD and IVA, are available from Bosch Security Systems for the VIP X1 XF standard version. If you select one of these algorithms, you can set the corresponding parameters here directly.
  • Page 67 You can reveal the tampering of cameras and video cables by means of various options. Run a series of tests at different times of the day and night to ensure that the video sensor is operating as intended. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.54 | 2011.09...
  • Page 68 Activate this function if tampering associated with EMC interference (noisy scene as the result of a strong interference signal in the vicinity of the video lines), as an example, should trigger an alarm. DOC | V4.54 | 2011.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
  • Page 69 Right-click any fields you wish to deactivate. Click OK to save the configuration. Click the close button X in the window title bar to close the window without saving the changes. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.54 | 2011.09...
  • Page 70: Advanced Mode: Vca Scheduled

    Click the Select All button to link all time intervals to the selected profile. Click the Clear All button to deselect all of the intervals. When you are finished, click the Set button to save the settings in the unit. DOC | V4.54 | 2011.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
  • Page 71 Click the date you wish to delete. Click OK. The item will be deleted from the table and the window will close. The process must be repeated for deleting additional days. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.54 | 2011.09...
  • Page 72: Advanced Mode: Vca Event Triggered

    NOTICE! For more information, please see the Alarm Task Script Language document and the RCP+ documentation. You can find these documents on the product CD supplied. DOC | V4.54 | 2011.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
  • Page 73: Advanced Mode: Audio Alarm

    A delay period may be useful in avoiding false alarms or frequent triggering, for example. During the delay period, the Silent MOTION+ configuration is always enabled. 5.32 Advanced Mode: Audio Alarm Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.54 | 2011.09...
  • Page 74 The name makes it easier to identify the alarm in extensive video monitoring systems, for example with the Bosch Video Client and Bosch Video Management System programs. You can also use the name in the Forensic Search program function as a filter option for quick search in recordings.
  • Page 75: Advanced Mode: Alarm E-Mail

    You can obtain information on operating your cellphone from your cellphone provider. Attach JPEG from camera Click the checkbox to specify that JPEG images are sent from the camera. An enabled video input is indicated by a check mark. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.54 | 2011.09...
  • Page 76 Test e-mail You can test the e-mail function by clicking the Send Now button. An alarm e-mail is immediately created and sent. DOC | V4.54 | 2011.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
  • Page 77: Advanced Mode: Alarm Task Editor

    Script successfully parsed. is displayed over the text field. If it was not successful, an error message will be displayed with further information. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.54 | 2011.09...
  • Page 78: Advanced Mode: Alarm Inputs

    You can select different events that automatically activate an output. It is possible, for example, to turn on a floodlight by triggering a motion alarm and then turning the light off again when the alarm has stopped. DOC | V4.54 | 2011.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
  • Page 79 Special characters are not supported by the system's internal recording and. Trigger relay Click the button to trigger the relay manually (for testing or to operate a door opener, for example). Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.54 | 2011.09...
  • Page 80: Advanced Mode: Com1

    Select a controllable unit from the list. If you wish to use the serial port to transmit transparent data, select Transparent. Select Terminal if you wish to operate the unit from a terminal. DOC | V4.54 | 2011.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
  • Page 81 Stop bits Select the number of stop bits per character. Parity check Select the type of parity check. Interface mode Select the desired protocol for the serial interface. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.54 | 2011.09...
  • Page 82: Advanced Mode: Network

    Some changes only take effect after the unit is rebooted. In this case, the Set button changes to Set and Reboot. Make the desired changes. Click the Set and Reboot button. The VIP X1 XF is rebooted and the changed settings are activated. DOC | V4.54 | 2011.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
  • Page 83 IP addresses automatically assigned to the VIP X1 XF. Certain applications (Bosch Video Client, Bosch Video Management System) use the IP address for the unique assignment of the unit. If you use these applications, the DHCP server...
  • Page 84 Enter the host name registered on DynDNS.org for the VIP X1 XF here. User name Enter the user name you registered at DynDNS.org here. Password Enter the password you registered at DynDNS.org here. DOC | V4.54 | 2011.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
  • Page 85 To transfer the IP address of the VIP X1 XF, click the Register button. Status The status of the DynDNS function is displayed here for information purposes. You cannot change any of these settings. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.54 | 2011.09...
  • Page 86: Advanced Mode: Advanced

    VIP X1 XF does not send the SNMP traps automatically, but only replies to SNMP requests. If you enter one or two SNMP host addresses, SNMP traps are sent automatically. Select Off to deactivate the SNMP function. DOC | V4.54 | 2011.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
  • Page 87 Select the port for TCP communication. Select Off to deactivate the TCP metadata function. Sender IP address Enter the IP address of the TCP metadata sender here. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.54 | 2011.09...
  • Page 88: Advanced Mode: Multicast

    With the setting 0.0.0.0 the encoder for the relevant stream operates in multi-unicast mode (copying of data streams in the unit). The VIP X1 XF supports multi-unicast connections for up to five simultaneously connected receivers. DOC | V4.54 | 2011.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
  • Page 89: Advanced Mode: Ftp Posting

    You can select how file names will be created for the individual images that are transmitted. – Overwrite The same file name is always used and any existing file will be overwritten with the current file. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.54 | 2011.09...
  • Page 90: Advanced Mode: Encryption

    The VIP X1 XF is designed in such a way that its functions and parameters can be updated with firmware. To do this, transfer the current firmware package to the unit via the selected network. It will then be automatically installed there. DOC | V4.54 | 2011.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
  • Page 91 You can upload the SSL certificate, comprising one or multiple files, onto the VIP X1 XF. If you wish to upload multiple files onto the VIP X1 XF, you must select them consecutively. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.54 | 2011.09...
  • Page 92: Advanced Mode: Licenses

    You can enter the activation key to release additional functions or software modules. NOTICE! The activation key cannot be deactivated again and is not transferable to other units. DOC | V4.54 | 2011.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
  • Page 93: Advanced Mode: System Overview

    You can select all required text on this page with the mouse and copy it to the clipboard with the [Ctrl]+[C] key combination, for example if you want to send it via e-mail. Bosch Sicherheitssysteme GmbH Installation and Operating Manual...
  • Page 94: Function Test

    – Does the VIP X1 XF respond to alarm events as required? – Do the recordings occur as intended? – Is it possible to control peripherals if necessary? DOC | V4.54 | 2011.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
  • Page 95: Operation

    Insert the product CD into the computer's CD-ROM drive. If the CD does not start automatically, open the root directory of the CD in Windows Explorer and double-click MPEGAx.exe. Follow the on-screen instructions. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.54 | 2011.09...
  • Page 96 Enter the IP address of the VIP X1 XF as the URL. During initial installation, confirm the security questions that appear. The connection is established and after a short time you will see the LIVEPAGE with the video image. DOC | V4.54 | 2011.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
  • Page 97: The Livepage

    If you do not connect, the unit may have reached its maximum number of connections. Depending on the unit and network configuration, each VIP X1 XF can have up to 25 Web browser connections or up to 50 connections via Bosch Video Client or Bosch Video Management System.
  • Page 98 The gap will automatically be replaced by the true video, as soon as the correct information is available. DOC | V4.54 | 2011.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
  • Page 99 The Eco-version only offers one relay.  To activate this, click the icon for the corresponding relay next to the video image. The icon will be red when the relay is activated. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.54 | 2011.09...
  • Page 100 When the connection maintaining voice contact with the VIP X1 XF is broken, the next user to make a connection to the VIP X1 XF can send audio data to the VIP X1 XF. DOC | V4.54 | 2011.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
  • Page 101: Saving Snapshots

    If the VIP X1 XF is accessed via the Web browser, you will see the processor load indicator in the top left of the window next to the manufacturer's logo. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.54 | 2011.09...
  • Page 102: Network Connection

    You can display information about the network connection. To do this, move the cursor over the i icon. Link Ethernet link type Uplink, speed of the outgoing data traffic Downlink, speed of the incoming data traffic DOC | V4.54 | 2011.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
  • Page 103: The Recordings Page

    Export to FTP button. Click Export to FTP to send the selected recordings to the FTP server. The information below the button allows you to monitor the export. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.54 | 2011.09...
  • Page 104 Use the slide control below the Start button to control playback speed. The default value of 100% represents real time speed. Higher values speed up the playback, lower values slow it down. DOC | V4.54 | 2011.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
  • Page 105 Bookmarks are only valid while you are in the RECORDINGS page; they are not saved with the sequences. As soon as you leave the page all bookmarks are deleted. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.54 | 2011.09...
  • Page 106: Hardware Connections Between Video Servers

    This option can also be used to connect a sender and a compatible receiver using a switch connected to the alarm input. You do not need a computer to make the connection in this case. DOC | V4.54 | 2011.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
  • Page 107 Start the terminal program and enter the command 4 in the main menu to switch to the Rcp+ menu. In the Rcp+ menu, enter command 3 to deactivate automatic connection. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.54 | 2011.09...
  • Page 108: Operation Using Software Decoders

    Bosch CCTV products as one component of an extensive video security management system. It allows you to integrate your existing components into a simple-to-control system or into the entire Bosch range, benefiting from a complete security solution based on the latest technology and years of experience.
  • Page 109: Maintenance And Upgrades

    NOTICE! After a reset, the unit can only be addressed via the factory default IP address. The IP address can be changed as described in the Installation chapter (see Section 4.5 Setup using Bosch Video Client, page 20). If necessary, back up the current configuration using the Download button on the Maintenance configuration page (see Section 5.43 Advanced Mode: Maintenance,...
  • Page 110: Repairs

    Transfer and disposal The VIP X1 XF should only be passed on together with this installation and operating manual. Your Bosch product is designed and manufactured with high-quality materials and components which can be recycled and reused. This symbol means that electrical and electronic equipment, at their end-of-life, should be disposed of separately from your household waste.
  • Page 111: Appendix

    If you are unable to resolve a malfunction, please contact your supplier or systems integrator, or go directly to Bosch Security Systems Customer Service. You can view a range of information about your unit version on the System Overview page (see Section 5.45 Advanced Mode: System Overview, page 93).
  • Page 112: General Malfunctions

    Audio configuration and LIVEPAGE Functions pages. The audio voice connection is Wait until the connection is free already in use by another and then call the sender again. receiver. DOC | V4.54 | 2011.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
  • Page 113 Active proxy server in network. Create a rule in the local empty fields. computer's proxy settings to exclude local IP addresses. The POWER LED flashes Firmware upload failed. Repeat firmware upload. red. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.54 | 2011.09...
  • Page 114: Malfunctions With Iscsi Connections

    LUN mapping is not Some iSCSI systems do not Delete the initiator extension on possible. support the use of an initiator the Identification configuration extension. page. DOC | V4.54 | 2011.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
  • Page 115: Leds

    Orange LED lights up: Data transmission via network connection. LINK LED (Eco-version only) Lights up green: Network connection established. ACT LED (Eco-version only) Lights up orange: Data transmission via network connection. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.54 | 2011.09...
  • Page 116: Processor Load

    The serial interface supports the RS-232, RS-422 and RS-485 transmission standards. The mode used depends on the current configuration (see Section 5.37 Advanced Mode: COM1, page 80). Connection is via the terminal block. DOC | V4.54 | 2011.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
  • Page 117: Terminal Block

    Connect each alarm input to a ground contact (GND) when connecting alarm inputs. Pin assignment I/O (Eco-version) Contact Function Alarm input Relay output Ground Connect the alarm input to a ground contact (GND). Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.54 | 2011.09...
  • Page 118: Communication With Terminal Program

    When you have entered a value, such as the IP address, check the characters you have entered before pressing Enter to transfer the values to the VIP X1 XF. DOC | V4.54 | 2011.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
  • Page 119 Additional parameters You can use the terminal program to check other basic parameters and modify them where necessary. Use the on-screen commands in the various submenus to do this. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.54 | 2011.09...
  • Page 120: Copyrights

    Corporation not be used in advertising or publicity pertaining to distribution of the software without specific, written prior permission. This software is based in part on the work of the Independent JPEG Group. DOC | V4.54 | 2011.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
  • Page 121: Specifications

    Video data rate 9.6 kbps to 6 Mbps Image resolutions (PAL/NTSC) 704 × 576/480 pixels (4CIF) 352 × 288/240 pixels (CIF) Total delay 240 ms max. (H.264 MP, GOP IP) Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.54 | 2011.09...
  • Page 122: Eco-Version

    IEC 60950-1; UL-listed; EN 50130-4; EN 50121-4; EN 55103-1; EN 55022 Class B; EN 55024; EN 61000-3-2; EN 61000-3-3; FCC 47 CFR Part 15 Subpart B Class B; AS/NZS 3548 Class B DOC | V4.54 | 2011.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
  • Page 123 L16, 300 Hz to 6.4 kHz Audio sampling rate G.711: 8 kHz L16: 16 kHz Audio data rate G.711: 80 kbps L16: 640 kbps Signal-to-noise ratio > 50 dB Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.54 | 2011.09...
  • Page 124: Glossary

    Unit of measure for the speed of data transmission Bits per second, the actual data rate BVIP Bosch Video over IP unit CompactFlash; interface standard, for digital storage media amongst other things. Used in computers in the form of CF cards, digital cameras and Personal Digital Assistants (PDA).
  • Page 125 It is controlled by a network operating system and uses a transfer protocol. Logical Unit Number; logical drive in iSCSI storage systems Media Access Control Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.54 | 2011.09...
  • Page 126 Real-Time Streaming Protocol; network protocol for controlling the continuous transmission of audiovisual data (streams) or software over IP-based networks SD card Secure Digital Memory Card; digital memory card that works on the flash principle DOC | V4.54 | 2011.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
  • Page 127 User Datagram Protocol Uniform Resource Locator Unshielded Twisted Pair See Wide Area Network Wide Area Network A long distance link used to extend or connect remotely located local area networks Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.54 | 2011.09...
  • Page 128: Index

    Low-pass filter 45 Device ID 33 Device name 26 DHCP server 29 Main functions 13 Display stamping 38 Maintenance 8 Dome camera 19 Manufacturer logo 40 Dual Streaming 11 DOC | V4.54 | 2011.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
  • Page 129 Recording scheduler 59 Transmission rate 81 Recording status 60 Transmission standards 19 Recording video sequences 101 Transparent 80 Reflections of light 67 Traps 87 Regulations 6 Trigger 19 Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.54 | 2011.09...
  • Page 130 Unit reset 109 Unit time 28 URL 23 User name 26 Value 45 VCR 44 Video content analysis 64 Video input 44 Video sensor 64 VRM 53 Watermarking 39 DOC | V4.54 | 2011.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
  • Page 132 Bosch Sicherheitssysteme GmbH Werner-von-Siemens-Ring 10 85630 Grasbrunn Germany www.boschsecurity.com © Bosch Sicherheitssysteme GmbH, 2011...

This manual is also suitable for:

Vip-x1xf-e

Table of Contents