VIP X1600 M4S
2.
CAUTION!
!
If you change the IP address, subnet mask or gateway address, the module is only available
under the new addresses after the reboot.
Automatic IP assignment
If a DHCP server is employed in the network for the dynamic assignment of IP addresses, you
can activate acceptance of IP addresses automatically assigned to the module.
Certain applications (VIDOS, Bosch Video Management System, Archive Player, Configuration
Manager) use the IP address for the unique assignment of the unit. If you use these
applications, the DHCP server must support the fixed assignment between IP address and
MAC address, and must be appropriately set up so that, once an IP address is assigned, it is
retained each time the system is rebooted.
IP address
Enter the desired IP address for the module. The IP address must be valid for the network.
Subnet mask
Enter the appropriate subnet mask for the selected IP address here.
Gateway address
If you want the module to establish a connection to a remote location in a different subnet,
enter the IP address of the gateway here. Otherwise leave the box blank (0.0.0.0).
DNS server address
Using a DNS server, the device can resolve an address indicated as a name. Enter the IP
address of the DNS server here.
Video transmission
If the VIP X1600 XF is operated behind a firewall, TCP (HTTP port) should be selected as the
transfer protocol. For use in a local network, select UDP.
CAUTION!
!
Multicast operation is only possible with the UDP protocol. The TCP protocol does not
support multicast connections.
The MTU value in UDP mode is 1,514 bytes.
HTTP browser port
Select a different HTTP browser port from the list if required. The default HTTP port is 80. If
you want to allow only secure connections via HTTPS, you must deactivate the HTTP port. In
this case, select Off.
HTTPS browser port
If you wish to allow browser access on the network via a secure connection, select an HTTPS
browser port from the list if necessary. The default HTTPS port is 443. Select the Off option
to deactivate HTTPS ports; only unsecured connections will now be possible.
The module uses the TLS 1.0 encryption protocol. You may have to activate this protocol via
your browser configuration. You must also activate the protocol for the Java applications (via
the Java control panel in the Windows control panel).
Bosch Security Systems
Click the Set and Reboot button. The module is rebooted and the changed settings are
activated.
Installation and Operating Manual
Configuration Using a Web Browser | en
DOC | V4.0 | 2009.06
75