General Malfunctions - Bosch VIP X1 Installation And Operating Manual

Operation manual
Table of Contents

Advertisement

EN | 124

General malfunctions

Malfunction
No connection
between the unit and
terminal program.
No image transmis-
sion to remote sta-
tion.
No connection estab-
lished, no image
transmission.
No audio transmis-
sion to remote sta-
tion.
Appendix
Possible causes
Incorrect cable connections. Check all cables, plugs, contacts,
The computer's serial inter-
face is not connected.
Interface parameters do not
match.
Camera error.
Faulty cable connections.
The unit's configuration.
Faulty installation.
Wrong IP address.
Faulty data transmission
within the LAN.
The maximum number of
connections has been
reached.
Hardware fault.
Faulty cable connections.
Incorrect configuration.
The audio voice connection
is already in use by another
receiver.
Installation and Operating Manual | VIP X1
Solution
terminals and connections.
Check the other serial interface.
If necessary select a different inter-
face and make sure that the com-
puter's interface parameters match
those of the unit. Try the following
standard parameters:
19,200 baud, 8 data bits, no parity,
1 stop bit. Next, disconnect the unit
from the power supply and recon-
nect it again after a few seconds.
Connect local monitor to the cam-
era and check the camera function.
Check all cables, plugs, contacts
and connections.
Check all configuration parame-
ters.
Check all cables, plugs, contacts
and connections.
Check the IP addresses
(terminal program).
Check the data transmission with
ping
.
Wait until there is a free connection
and then call the sender again.
Check that all connected audio
units are operating correctly.
Check all cables, plugs, contacts
and connections.
Check the audio parameters on the
Audio settings and Livepage
configuration configuration
pages.
Wait until the connection is free
and then call the sender again.
Bosch Security Systems | 2006-12 | V2.5