en | Configuration Using a Web Browser
SNMP host addresses, SNMP traps are sent automatically. Select Off to deactivate the SNMP
function.
1. SNMP host address / 2. SNMP host address
If you wish to send SNMP traps automatically, enter the IP addresses of one or two required
target units here.
SNMP traps
You can select which traps are to be sent.
1.
2.
3.
Authentication (only for the module in Slot 1)
If a RADIUS server is employed in the network for managing access rights, authentication
must be activated here to allow communication with the unit. The RADIUS server must also
contain the corresponding data.
To configure the unit, you must connect the VIP X1600 XF directly to a computer using a
network cable. This is because communication via the network is not enabled until the
Identity and Password parameters have been set and successfully authenticated.
CAUTION!
!
The switch used for the network must support the multi-host operation when using 802.1x
authentication and must be configured so that a VIP X1600 XF with several modules can try
several hosts for communicating over the network.
Identity (only for the module in Slot 1)
Enter the name that the RADIUS server is to use for identifying the VIP X1600 XF.
Password (only for the module in Slot 1)
Enter the password that is stored in the RADIUS server.
RTSP port
If necessary, select a different port for the exchange of the RTSP data from the list. The
standard RTSP port is 554. Select Off to deactivate the RTSP function.
DOC | V4.0 | 2009.06
Click Select. A list is opened.
Click the checkboxes to select the required traps. All the checked traps will be sent.
Click Set to accept the selection.
Installation and Operating Manual
VIP X1600 M4S
Bosch Security Systems