A lighter version of the previous image remains and is repeatedly
printed
The GS settings need to be adjusted.
1
Configure the settings for GS.
1
Select the [System Menu / Counter] key > [Adjustment/Maintenance] > "Others" > [GS].
Increase the value one level from the current value.
2
Select the [System Menu / Counter] key > [Adjustment/Maintenance] > "Image Adjustment" [Image
Adjustment].
Perform only calibration.
3
Print a document and confirm the image quality.
Increase the value until the image is improved.
NOTE
If there is still no improvement, return the setting to the original value.
2
If white dots appear in the improved image, decrease the value by one level.
3
If the white background of the improved image appears colored, proceed to the next
step. If there is no unnecessary coloring, finish editing.
4
Configure the settings for MC.
1
Select the [System Menu / Counter] key > [Adjustment/Maintenance] > "Others" > [MC].
Increase the value one level from the current value.
2
Select the [System Menu / Counter] key > [Adjustment/Maintenance] > "Image Adjustment" [Image
Adjustment].
Perform only calibration.
3
Print the document and confirm the image quality.
Increase the value until the image is improved.
NOTE
If there is still no improvement, return the setting to the original value.
5
If white dots or color dots appear in the improved image, decrease the value by one
level.