Service Menu: Input And Output Test; Output Test - Thermoplan AGUILA AG220 Technical Manual

Hide thumbs Also See for AGUILA AG220:
Table of Contents

Advertisement

Troubleshooting - Aguila - 220 - B - en
2

Service Menu: Input and Output Test

2.1

OUTPUT TEST

In this menu the functionality of all electrical components in the machine can be tested.
Press input button.
u
ð Water inlet valve is closed.
• If a "click" sound can be heard when releasing the
button, the valve works.
Press input button.
u
ð Brewing chamber valve 1 is opened.
• If the brewing chamber is closed, a "click" sound
should be heard.
Press input button.
u
ð Brewing chamber valve 2 is opened.
• If the brewing chamber is closed, a "click" sound
should be heard.
Press input button.
u
ð Brewing valve 1 is opened.
• If the brewing chamber is closed, a "click" sound
should be heard.
Press input button.
u
ð Brewing valve 2 is opened.
• If the brewing chamber is closed, a "click" sound
should be heard.
Press input button.
u
ð Tea valve on the boiler is opened.
• If a "click" sound can be heard, the valve works.
Press input button.
u
ð Venting valve is opened.
• If a "click" sound can be heard, the valve works.
Press input button.
u
ð Milk cleaning valve is opened.
• If a "click" sound can be heard, the valve works.
Press input button.
u
ð Milk rinsing valve is opened.
• If a "click" sound can be heard, the valve works.
© Thermoplan AG
Service Menu: Input and Output Test
OUTPUT TEST
Water Inlet Valve
OUTPUT TEST
Chamber Release Valve 1
OUTPUT TEST LEFT / RIGHT
Chamber Release Valve 2
OUTPUT TEST
Brew Valve 1
OUTPUT TEST
Brew Valve 2
OUTPUT TEST
Tea Valve
OUTPUT TEST
Venting valve
OUTPUT TEST
Milk Clean Valve
OUTPUT TEST
Milk Rinse Valve
7 / 52