Troubleshooting - Aguila - 220 - B - en
• 24 V Power supply from CUP via HAPB
2 CN2, CCI interface
• Connection for cash register system
3 CN7, refrigerator
• Level detector milk is empty
• Level detector milk is almost empty
• NTC Milk
• 24V Fan
Milk cleaning key
4 CN5, control panel
• Keyboard print
5 CN14 RS485 (external)
• Programming box
6 X6, General Inputs/Outputs
• Programming key for service menu
• Energy saving mode button
• Cleaning valve
• Tea Valve 2
• Venting valve
7 BAT1, 3V battery
• Real-time clock
© Thermoplan AG
• Flowmeter inlet coffee 1
• Flowmeter inlet coffee 2
• Detection of capsule collecting container
• Brewing unit 1 microswitch
• Brewing unit 2 microswitch
9 CN1, CF card slot
• CF card (software update)
10 CN9, NTC Probes (NTC probe)
• NTC Coffee boiler 1
• NTC Coffee boiler 2
• NTC tea/milk boiler
11 CN8 Coffee Valves
• Water inlet valve
• Brewing valve 1
• Brewing valve 2
• Brewing chamber valve 1
• Brewing chamber valve 2
• Tea valve
12 X1, Milk Valves
• Milk outlet valve
• Milk drain valve
• Milk selection valve
• Milk rinse valve
13 CN11, Power Supply 24V
• 24 V Power supply (switching power
supply)
14 CN3, Milk Pump
• Milk pump control
• (Hall sensors)