Thermoplan AGUILA AG220 Service And Technical Manual
Thermoplan AGUILA AG220 Service And Technical Manual

Thermoplan AGUILA AG220 Service And Technical Manual

Hide thumbs Also See for AGUILA AG220:

Advertisement

Quick Links

Black
SECTION III
AG220 / AG420
Service and Technical Manual
White
Service menu
3.1
REV-6
© 2016 by Thermoplan AG, Subject to change

Advertisement

Table of Contents
loading

Summary of Contents for Thermoplan AGUILA AG220

  • Page 1 Black SECTION III AG220 / AG420 Service and Technical Manual White Service menu REV-6 © 2016 by Thermoplan AG, Subject to change...
  • Page 2 Added model AG220; miscallenous corrections 2015-05-04 Added information for learning mode 2015-08-13 Added statistic menus „Brewing unit“ and „Brewing unit reset“ for the AG420 2016-04-19 Description of menu „Load firmware“ adjusted REV-6 © 2016 by Thermoplan AG, Subject to change...
  • Page 3: Table Of Contents

    Tea / milk boiler ..................................3.18 Cleaning parameters ................................3.19 Output test left / right ................................3.19 Input test left right ................................3.21 Products ....................................3.23 Error history ..................................3.26 Neslink ....................................3.26 Installation ................................... 3.28 REV-6 © 2016 by Thermoplan AG, Subject to change...
  • Page 4: Accessing The Service Menu

    Figure shows model AG420 Note: Model AG220 does not feature the two air regulators. To exit the service menu: Turn the programming key anti-clockwise and remove it, the main display („Ready“) is shown again. REV-6 © 2016 by Thermoplan AG, Subject to change...
  • Page 5: Navigation / Changing Values

    If key is flashing you can reset the value to the machine‘s default value. Press key to save the changed values. Press key to exit the menu without saving. REV-6 © 2016 by Thermoplan AG, Subject to change...
  • Page 6 The new setting is activated and the initial menu will appear. TECHNICIAN MENU Refrigerator temp. = 4.0 °C Leave the User or Technician Level (see page 4). <- Ready Ready -> REV-6 © 2016 by Thermoplan AG, Subject to change...
  • Page 7: List Of Menu Points

    NTC Boiler 3 ² only available for model AG420 Time for mode 2 NTC Cooling On after cleaning Milk temperature Flowmeter 1 Flowmeter 2 Milk Level Low Milk Container Empty Energy Save Button REV-6 © 2016 by Thermoplan AG, Subject to change...
  • Page 8: User Level

    < LATTE > pressed. The following recipes are available: Cortado Lungo, Cortado, Flat White, Cappuccino Lungo, Cappuccino Chiaro, Cappuccino Freddo, Iced Cappuccino, Latte Grande, Latte, Latte Piccolo, Iced Latte, Macchiatissimo, Cold Milk. REV-6 © 2016 by Thermoplan AG, Subject to change...
  • Page 9: Statistics

    „Yes“ by using the Up- / Down-key and confirm with the User counter reset Enter-key. Shows the total of all dispensed products. STATISTICS Product counter = Shows the total of all dispensed pad products. STATISTICS PAD products counter = REV-6 © 2016 by Thermoplan AG, Subject to change...
  • Page 10: Machine Parameters

    This value gets reset to 0.0 %, if the settings for „Cold air“ are adju- sted in the Technician Level under „Products“. 3.10 REV-6 © 2016 by Thermoplan AG, Subject to change...
  • Page 11: Technician Level

    3. The machine will go back to the previous menu after a few seconds. The data has been copied to the CF-card. 4. Remove the CF-card from the card slot. 3.11 REV-6 © 2016 by Thermoplan AG, Subject to change...
  • Page 12 CF-card, the card must be formatted. When using Windows, press on „Restore device defaults“ and uncheck the option „Quick Format“. 1. Download the new software off the Thermoplan Online Campus. Extract the content of the zip-file onto the formatted CF-card. Make sure that only the folder „FIRMWARE“...
  • Page 13: Statistics

    The value on the bottom left shows the amount dispensed on the left outlet of the module, the value on the right shows the amount dispensed on the right outlet. 3.13 REV-6 © 2016 by Thermoplan AG, Subject to change...
  • Page 14 Enter-key. Shows the total amount of all dispensed products. STATISTICS Product counter = x Shows the total amount of all dispensed pad products. STATISTICS PAD products counter = x 3.14 REV-6 © 2016 by Thermoplan AG, Subject to change...
  • Page 15: Machine Parameters

    Set the max. amount of products which can be dispensed, before the Product counter max. = 48 x 1000 message „Service required“ appears on the display. [ 10 .. < 48 x1000 > .. 100 ] 3.15 REV-6 © 2016 by Thermoplan AG, Subject to change...
  • Page 16: Energy Save Mode

    Press the Energy Save Button to start up the machine. If set to „On“, the machine will enter standby mode 2 after a cleaning Enter after cleaning = On has been performed. < On > 3.16 REV-6 © 2016 by Thermoplan AG, Subject to change...
  • Page 17: Milk Settings

    A lower value leads to more liquid foam, a higher value leads to more solid foam. This value gets reset to 0.0 %, if the settings for „Cold air“ are adju- sted under „Products“. 3.17 REV-6 © 2016 by Thermoplan AG, Subject to change...
  • Page 18: Coffee Boiler

    As soon as the coffee boiler reaches the „Nom. temperature“ minus [ 0 .. < 2 °C > .. 4 ] the tolerance value, the machine will be ready for dispensing tea and milk products. 3.18 REV-6 © 2016 by Thermoplan AG, Subject to change...
  • Page 19: Cleaning Parameters

    Brew Valve 2 Press the Enter-key to open the Tea Valve on the boiler. OUTPUT TEST LEFT / RIGHT The valve is functioning correctly if a „click“ noise is heard. Tea Valve 3.19 REV-6 © 2016 by Thermoplan AG, Subject to change...
  • Page 20 Water Pump Press and hold the Enter-key to test the Milk Pump. OUTPUT TEST LEFT / RIGHT A short press of the Enter-key will start an internal rinse. Milk Pump 3.20 REV-6 © 2016 by Thermoplan AG, Subject to change...
  • Page 21: Output Test Left / Right

    (Yes) or not (No). Cleaning tablet = No The display shows the current state of brew chamber 1. INPUT TEST LEFT / RIGHT Brew Chamber 1 = open 3.21 REV-6 © 2016 by Thermoplan AG, Subject to change...
  • Page 22 The display shows the current state of the Energy Save Button. INPUT TEST LEFT / RIGHT If the Energy Save Button is pressed , the state will change to „On“. Energy Save Button = Off 3.22 REV-6 © 2016 by Thermoplan AG, Subject to change...
  • Page 23: Products

    The set value (in sec.) defines, how long hot water will be dispensed [ 0.0 .. < x.x s > .. 65.0 ] (for products dispensed on the left module). » Learning mode 3.23 REV-6 © 2016 by Thermoplan AG, Subject to change...
  • Page 24 The set value (in sec.) defines, how long foam will be dispensed (for [ 0.0 .. < x.x s > .. 60.0 ] products dispensed on the left module). » Learning mode 3.24 REV-6 © 2016 by Thermoplan AG, Subject to change...
  • Page 25 This menu is used for delaying the dispense (in sec.) of coffee (e.g. Coffee delay = x s needed for Macchiato products, to let the milk foam settle in the cup). [ 0 .. < x s > .. 30 ] 3.25 REV-6 © 2016 by Thermoplan AG, Subject to change...
  • Page 26: Error History

    NL act. date = 26.05.2014 Nespresso server. In this menu Neslink can be activated or deactivated. NESLINK Neslink activation = Yes 3.26 REV-6 © 2016 by Thermoplan AG, Subject to change...
  • Page 27 By activating, the machine will send a data package as test to the NESLINK Nespresso server. The message „Package sent“ is shown, if the Neslink Test package was sent successfully. 3.27 REV-6 © 2016 by Thermoplan AG, Subject to change...
  • Page 28: Installation

    Eagle Hardware Version = xxxx (only available for model AG220) INSTALLATION In this menu the CCI-Interface can be activated (needed for a CCI activated = Yes connection to a cash register system). 3.28 REV-6 © 2016 by Thermoplan AG, Subject to change...

This manual is also suitable for:

Aguila ag420

Table of Contents