Troubleshooting - Aguila - 220 - B - en
ð The number of ticks is displayed (brewing
chamber must be closed).
• Displays the current milk temperature in the
refrigerator.
• If the temperature is above 12 °C, the preparation
of milk products is blocked.
• If a temperature of 3276.8 °C is displayed, either a
cable break or short-circuit at the NTC has
occurred.
• Displays the status of the upper milk level sensor.
• "Off": "Milk level low" not reached (continuity
exists), there is still sufficient milk in the container.
• "On": "Milk level low" reached, milk level is below
the sensor (no continuity), milk almost empty.
• Displays the status of the lower milk level sensor.
• "Off": "there is still milk in the container
(continuity exists).
• "On": Milk level is below the sensor (no
continuity), there is no more milk left.
• Displays the current status of the energy standby
button.
Press energy standby button.
u
ð Display changes to "On".
• "Off": Button is not pressed, standby mode is not
activated.
• "On": Button is pressed, standby mode is
activated.
© Thermoplan AG
Service Menu: Input and Output Test
INPUT TEST
Milk temperature = x.x °C
INPUT TEST
Milk Level Low = O
INPUT TEST
Milk Container Empty = O
INPUT TEST
Energy Save Button = O