Display Messages - Thermoplan AGUILA AG220 Technical Manual

Hide thumbs Also See for AGUILA AG220:
Table of Contents

Advertisement

Troubleshooting - Aguila - 220 - B - en
2 LD2: Water pump
3 LD3: Compressor
8.7

Display Messages

Messages
Insert capsule drawer!
Empty capsule drawer!
Energy saving mode
© Thermoplan AG
Press any key
Change water lter
Service required
Call technician
5 LD5: Coffee boiler 1
6 LD6: Coffee boiler 2
Possible Cause
• Capsule container not inserted
or not inserted correctly.
• Reed contact defective.
• Magnet on drawer missing.
• Maximum number of capsules
in capsule container reached.
• Coffee machine is in energy
saving mode.
• Maximum Energy Saving Mode
active
• Machine is switched off (main
switch in "OFF" position).
• Filter cartridge is exhausted.
• Coffee machine has reached
max. number of brews; 12
months since installation/last
PM.
• Displayed to the user if NTC
milk pump or flowmeter errors
occur.
• Repeated technical fault.
Solution
Insert capsule container
u
correctly.
Check reed with input test.
u
Replace magnet.
u
Empty capsule container and
u
insert again.
Press any button to return to
u
the operating mode.
Press energy saving button 3x
u
to restart coffee machine.
Switch on main switch.
u
Replace filter cartridge and
u
reset water counter (service
menu "Statistics" ► "Water
volume Reset").
Carry out PM and reset service
u
counter.
Switch machine off and on
u
again. Prepare product anew.
Examine error trace and
u
eliminate any recently occurred
errors.
Carry out irregular PM. Do not
u
reset service counter!
Electronics