4.2

Water Channel to the Pump

Water channel until pump and detailed view of water connection with non-return valve:
10
9
8
1
Water inlet valve
3
Filter
5
Reduction MW
7
Elbow fitting
9
Bottom plate
4.3

Detailed View of Pressure Gauge/Bypass

The water inlet pressure must be between 2-4 bar when the machine is switched on.
During preparation of a coffee product and a correspondingly activated water pump, the brewing pressure
must increase to 14.5 bar.
To check the pressure during preparation of the product: Remove the capsule container on the left module
and dispense a product on the right module.
If the brewing pressure does not match the required values, the bypass can be adjusted as follows:
Loosen hexagon nut to adjust bypass.
u
Adjust bypass:
u
• clockwise: increase pressure
• anticlockwise clockwise: decrease pressure
Tighten hexagon nut again.
u
© Thermoplan AG
Possible Cause
1
2
4
6
8
10
Solution