Coffee/Water Part; Possible Problems - Thermoplan AGUILA AG220 Technical Manual

Hide thumbs Also See for AGUILA AG220:
Table of Contents

Advertisement

Coffee/Water Part

4
Coffee/Water Part
4.1

Possible Problems

Messages
No product/display message
"Flowmeter # error"
Display message
"Error: NTC # short-circuit"
Display message
"Error: NTC # breakage"
Water under the machine
Long heating up time/Display
message
"Heating up"/
"Please wait"
18 / 52
Possible Cause
• Hoses of the water circuit or
brewing unit not connected
correctly.
• Flowmeter plug oxidised.
• Microswitch inserted in reverse
on the brewing unit.
• No water supply.
• Filter in the water inlet/
flowmeter blocked.
• Water flow too low or
interrupted.
• Electrical circuit interrupted.
• # = 1: Coffee boiler 1.
• # = 2: Coffee boiler 2.
• # = 3: Tea/milk boiler.
• NTC short-circuit.
• Short-circuit in the NTC circuit.
• # = 1: Coffee boiler 1.
• # = 2: Coffee boiler 2.
• # = 3: Tea/milk boiler.
• Interruption of the NTC from
boiler.
• Interruption in the NTC circuit.
• Leak.
• The corresponding boiler has
not yet reached the operating
temperature.
• Defective NTC on the boiler.
• Defective component in the
corresponding heating circuit.
• Boiler has limescale.
Troubleshooting - Aguila - 220 - B - en
Solution
Connect hoses of the water
u
circuit or brewing unit
correctly.
Check everything and replace if
u
necessary.
Connect microswitch correctly.
u
Check water inlet valve.
u
Check filter.
u
Check water flow to brewing
u
group.
Check electrical circuit until the
u
flowmeter.
Check NTC of the
u
corresponding coffee boiler.
Measured value: 10 kΩ at 25
°C.
Check electrical circuit of the
u
NTC.
Check brewing unit for water
u
leakage.
Hoses from the 3rd channel
u
"outlet" not connected to
module; cracks in the hose;
check all hose connections.
When after cold start rinsing:
u
Clean coffee outlet.
Check brewing unit for water
u
leakage.
Hoses from the 3rd channel
u
"outlet" not connected to
module; cracks in the hose;
check all hose connections.
When after cold start rinsing:
u
Clean coffee outlet.
Wait until operating
u
temperature is reached
("Ready").
In the "Input test" service
u
menu check the NTC.
Check complete heating circuit:
u
CPU/Powerprint/Triac;
temperature fuses; heating
element.
© Thermoplan AG