Service Menu: Input and Output Test
2.2

INPUT TEST

In this menu the functionality of all inputs (sensors) in the machine can be tested.
• Displays the current status of the grounds drawer.
• Displays the current status of the cleaning key.
• "closed" Cleaning key present and inserted/locked
correctly.
• "open": Cleaning key not present.
• Displays whether a cleaning tablet is in the
cleaning key.
• "No": No tablet is present in the key (reed switch
closed).
• "Yes": Tablet is present in the key (reed switch
open).
• Displays the current status of brewing chamber 1.
• "open": Brewing chamber is opened (microswitch
is open).
• "closed": Brewing chamber is closed (microswitch
is pressed).
• Displays the current temperature of coffee boiler 1.
• If a temperature of 3276.8 °C is displayed, either a
cable break or short-circuit at the NTC has
occurred.
• Displays the current temperature of coffee boiler 2.
• If a temperature of 3276.8 °C is displayed, either a
cable break or short-circuit at the NTC has
occurred.
• Displays the current temperature of the tea/milk
boiler.
• If a temperature of 3276.8 °C is displayed, either a
cable break or short-circuit at the NTC has
occurred.
• Displays the current temperature inside the
refrigerator.
• If a temperature of 3276.8 °C is displayed, either a
cable break or short-circuit at the NTC has
occurred.
• Displays the impulses of flowmeter 1.
Press and hold down the input button to test the
u
flowmeter.
10 / 52
Troubleshooting - Aguila - 220 - B - en
INPUT TEST
INPUT TEST
Cleaning key = closed
INPUT TEST
Cleaning tablet = No
INPUT TEST
Brew Chamber 1 = open
INPUT TEST
NTC Boiler 1 = xx.x °C
INPUT TEST
NTC Boiler 2 = xx.x °C
INPUT TEST
NTC Boiler 3 = xx.x °C
INPUT TEST
NTC Refrigerator = x.x °C
INPUT TEST
Flowmeter 1 = x ticks