Display Messages - Thermoplan Aguila AG440 Technical Manual

Table of Contents

Advertisement

Electronics
2 LD6 Coffee boiler 2
3 LD5 Coffee boiler 1
8.8

Display Messages

Messages
Insert capsule drawer!
Empty capsule drawer!
Energy saving mode
50 / 52
Press any key
Change water lter
Service required
Call technician
5 LD1 Cup heater
6 LD2, Module left: Water pump 208 V,
Possible Cause
• Capsule container not inserted
or not inserted correctly.
• Reed contact defective.
• Magnet on drawer missing.
• Maximum number of capsules
in capsule container reached.
• Coffee machine is in energy
saving mode.
• Maximum Energy Saving Mode
active
• Machine is switched off (main
switch in "OFF" position).
• Filter cartridge is exhausted.
• Coffee machine has reached
max. number of brews; 12
months since installation/last
PM.
• Displayed to the user if NTC
milk pump or flowmeter errors
occur.
• Repeated technical fault.
Troubleshooting - Aguila - 440 - B - en
module right: Refrigerator compressor 208 V
Solution
Insert capsule container
u
correctly.
Check reed with input test.
u
Replace magnet.
u
Empty capsule container and
u
insert again.
Press any button to return to
u
the operating mode.
Press energy saving button 3x
u
to restart coffee machine.
Switch on main switch.
u
Replace filter cartridge and
u
reset water counter (service
menu "Statistics" ► "Water
volume Reset").
Carry out PM and reset service
u
counter.
Switch machine off and on
u
again. Prepare product anew.
Examine error trace and
u
eliminate any recently occurred
errors.
Carry out irregular PM. Do not
u
reset service counter!
© Thermoplan AG