IQ7A-72-E-ACM-INT Microinverter specifications

Topic
Commonly used module pairings
Peak power tracking voltage
Operating voltage range
Maximum input DC voltage
Minimum/maximum start voltage
Maximum operating PV input current
Maximum DC input short circuit current (module lsc)
Overvoltage class DC port
DC Port backfeed under single fault
PV array configuration
Maximum continuous AC output power (-40°C to
65°C)
Rated output apparent power
Peak output power
Power factor (adjustable)
Nominal AC output voltage range
230 VAC (single-phase)
Nominal output current
-
230 VAC (single
phase)
Rated AC output current
Maximum Output fault current
Current (inrush)
Nominal frequency
Extended frequency range
Maximum AC output over current protection device
Protective class (all ports)
Overvoltage class AC port
34
IQ7A-72-E-ACM-INT Microinverter parameters
DC parameters
10
AC parameters
© 2023 Enphase Energy Inc. All rights reserved.
IQ Microinverters for AC Module applications
Unit
Min
W
V
18
V
18
V
V
33
A
A
A
1 x 1 ungrounded array; No additional DC side
protection required; AC side protection requires
max 20 A (single-phase)/25 A (multi-phase) per
branch circuit
VA
VA
VA
0.8 leading
0.8 lagging
Vrms
219
Arms
A
A
A
Hz
Hz
45
A
20 A (single-phase)/25 A (multi-phase)
per branch circuit
Typical
Max
295−460+
58
58
58
58
10.2
15
II
0
349
349
366
264
1.37
1.52
0.784
0
50
55
II
III
June 2023