Iq7A-72-E-Acm-Int Specifications - enphase IQ 7 Installation And Operation Manual

Microinverters for acm applications
Table of Contents

Advertisement

Topic
Static MPPT efficiency (weighted, ref EN 50530)
Total harmonic distortion
Ambient temperature range
Night tare loss
Storage temperature range
Dimensions not including mounting bracket
(approximate)
Connector type
Weight
Environmental Category / UV Exposure rating
Cooling
Relative humidity range
Approved for wet locations
Pollution Degree
Maximum altitude
Communication
Compliance
Grounding
Monitoring
Integrated DC disconnect
Integrated AC disconnect

IQ7A-72-E-ACM-INT Specifications

Topic
Commonly used module pairings7
Peak Power Tracking Voltage
Operating range
Maximum DC input voltage
Minimum / Maximum start voltage
35
IQ7X-96-ACM-INT Microinverter Parameters
Features and Specifications
IQ7A-72-E-ACM-INT Microinverter Parameters
DC Parameters
© 2021 Enphase Energy Inc. All rights reserved.
IQ Microinverter for ACM Applications
Unit
Min
%
99.5
%
C
-40
mW
C
-40
219 mm x 191 mm x 37.9 mm
MC-4 or Amphenol UTX
1.5 kg (3 lbs.)
IP67 Outdoor
Natural convection - no fans
4% to 100% condensing
Yes
PD3
2000 meter (6561 feet)
Power line
AS 4777.2, RCM, IEC/EN 61000-6-3, IEC/EN 62109-
1, IEC/EN 62109-2
The DC circuit meets the requirements for ungrounded
PV arrays in NEC. Ground fault protection (GFP) is
integrated into the class II double insulated
microinverter.
Enlighten Manager and MyEnlighten monitoring
options require an Enphase IQ Envoy
The DC connector has been evaluated and approved
for use as the load-break disconnect.
The AC connector has been evaluated and approved
for use as the load-break disconnect.
Unit
Min
295 W - 460+ W
V
18
V
18
V
V
33
Typical
Max
5
+60
50
+85
Typical
Max
58
58
58
58
January 06, 2021

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents