enphase IQ7 Installation And Operation Manual page 33

Microinverters for ac module applications
Table of Contents

Advertisement

Compatibility
Dimensions not including mounting bracket
Connector type
Weight
Environmental category/UV exposure rating
Maximum altitude
Cooling
Relative humidity range
Approved for wet locations
Pollution degree
Communication
Standard warranty term
Compliance
Grounding
Monitoring
Integrated DC disconnect
Integrated AC disconnect
12 Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area.
33
IQ7X-96-ACM-INT Microinverter parameters
Features and specifications
© 2023 Enphase Energy Inc. All rights reserved.
IQ Microinverters for AC Module applications
Pairs with 96-cell PV modules only
219 mm x 191 mm x 37.9 mm (approximate)
Enphase DC Connector
1.5 kg (3 lbs.)
IP67/outdoor
2,000 metres
Natural convection-no fans
4% to 100% condensing
Yes
PD3
Power line
enphase.com/warranty
NRS-097-2-1:2017, AS/NZS 4777.2, RCM,
IEC/EN 61000-6-3, IEC/EN62109-1, IEC/EN
62109-2
The DC circuit meets the requirements for
ungrounded PV arrays. Ground fault protection
(GFP) is integrated into the class II double-
insulated microinverter.
Enphase Installer Portal monitoring options
require an Enphase IQ Gateway.
The DC connector has been evaluated and
approved for use as the load-break disconnect.
The AC connector has been evaluated and
approved for use as the load-break disconnect.
June 2023