6.3 Clean the Build Chamber ................................14 6.4 Power Health Check ..................................15 6.4.1 Cleaning the Laser Lens ..............................15 6.4.2 Measure Power Health ..............................16 6.5 Refill Powder ....................................18 6.5.1 Gravity Powder Status ...............................18 3D Systems, Inc. p/n 74-D001, Rev. A...
Page 3
LIGHT INDICATORS AND DISPLAY ....................20 7.1 Various Modes ..................................... 22 SERVICE AND SUPPORT ........................24 GRAVITY EC DECLARATION OF CONFORMITY ................25 3D Systems, Inc. p/n 74-D001, Rev. A...
3D Systems may (but shall not be obligated to) make improvements to this document from time to time. However, the Licensed User acknowledges that at any time after the expiration of the date of issuance, 3D Systems may institute a periodic charge or fee payable by the Licensed User in return for ongoing receipt of improvements.
Gravity system. Safety Symbols and Definitions The following are safety symbols that are common to 3D Systems guides. Some or all of these symbols may appear in this guide and/or in other Gravity documentation. CAUTION: Indicates the possibility of loss of data or damage to equipment.
WARNING: THE GRAVITY BECOMES VERY HOT INSIDE THE BUILD CHAMBER AND ADJACENT PARTS. NEVER TOUCH THE INTERIOR SURFACES OF THE GRAVITY OR THE HEATING ELEMENTS. ALWAYS ALLOW THE GRAVITY TO COOL DOWN. In case of any Gravity breakdown contact 3D Systems for service and maintenance. 2.2 Personal Protective Equipment Face Mask Wear Protective Mask: A face mask should always be used when handling loose powder in order to minimize the amount of inhaled particles.
Sealed lid with patented refill interface. 2.4 Material Safety All materials certified by 3D Systems are safe during normal operation. However, you should be aware of the following issues: • Any material, material-like substance, or airborne cloud of material has a remote chance of rapid combustion.
Page 8
Material Handling Precautions During normal operation of the Gravity using 3D Systems’ materials, you are not required to wear a dust mask or special personal protection equipment unless specifically designated. Check the SDS of the material used for the specific precautions you should observe.
Disposal of Gravity Material and Waste Follow any applicable local regulations. Emissions Material heating - Analytical testing on 3D Systems materials indicates no detectable emissions outside acceptable limits from the Gravity system. 2.6 Electrical Safety Electrical Shock: Hazardous voltage exists inside the enclosures of all SLS equipment. Injury or death from electrical shock can result if you remove external panels or try to defeat safety interlocks.
If the injury was determined to be the result of laser radiation overexposure, please send a report to: Attention: Laser Safety Officer 3D Systems, Inc. 333 Three D Systems Circle Rock Hill, South Carolina, 29730 USA Include the following information in your report: •...
Connect with an Ethernet cable (not included): minimum Cat5, or Cat5e or Cat6 for 1000BASE-T Sound Emission Does not exceed 80 dB(A). Printer Control WeMote Interactive touchscreen Ventilation Well ventilated with free-flowing air. 3D Systems, Inc. p/n 74-D001, Rev. A...
Gravity includes a WeMote display with touchscreen and status lights. It serves as the user interface for the machine operation of the Gravity. The status lights indicate the printer’s state. Refer to chapter 7. “The light indicators and display” to understand the meaning of the status lights. 3D Systems, Inc. p/n 74-D001, Rev. A...
49152-65535 turn.wematter3d.com UDP/DTLS Used by Deep Space to stream video from Gravity. 4.3 Moving the Gravity Please contact 3D Systems Support prior to moving the equipment. Make sure that you use an adequate forklift to move the machine. 3D Systems, Inc.
Gatekeeper, you may invite your colleagues once you have logged in with your newly created account. 5.2 Preparing a Job in Deep Space Instructions on how to use Deep space to prepare a print job are available in the Learn section in Deep Space. 3D Systems, Inc. p/n 74-D001, Rev. A...
5.4 Emergency and Exceptional Situations 3D Systems has made every effort to provide you with guidance and information to be able to use and manage Gravity satisfactorily but sometimes things go wrong. Our first course of action is to use our sensors, data, and algorithms to reduce the impact.
3. Power health check 4. Refill the machine with powder Note: 3D Systems provides instructions to advise skilled and non-skilled persons in installing, operating, and maintaining the Gravity. The Gravity shall only be maintained by a qualified and trained person.
3. Check the recoater blade edge for possible irregularities or fine particles. Irregularities should be removed with a Cleaning Wipe and AirGlow Machine Cleaner. If that does not help, lightly use Scotch-Brite along the blade. 3D Systems, Inc. p/n 74-D001, Rev. A...
The lens is located in the ceiling of the build chamber, centered above the build volume. Do not remove the lens from the build chamber, it should be cleaned from its operational position. 3D Systems, Inc. p/n 74-D001, Rev. A...
There is an indication at the bottom of the display if the laser meter is hot or not. Close the machine door. 7. Click “Power” on the WeMote. 3D Systems, Inc. p/n 74-D001, Rev. A...
Page 20
If there is a connection problem with the Gravity a dialog will appear communicating that there is no internet connection. Please check the Ethernet cable at the back of the Gravity and the internet connection. If this does not solve the issue please contact 3D Systems ®...
From this example picture, we can conclude that the Gravity can be filled with 2 additional powder packages. • The information icon is pressable and when pressed it will extend the powder meter to display more information. 3D Systems, Inc. p/n 74-D001, Rev. A...
Page 22
• Refill will be possible again once Gravity has processed the inserted powder packages, which can take a few hours. 3D Systems, Inc. p/n 74-D001, Rev. A...
In printing mode, the machine is printing and no interaction is allowed. During the printing state, the indication lights are pulsating slowly in white. When the printing is finished the next state is applied. 3D Systems, Inc. p/n 74-D001, Rev. A...
Page 24
Powder Refill Needed - Yellow Light When the powder level is low, this is indicated on the WeMote display and the color yellow is displayed. This is not the same warm tone as in preparing. 3D Systems, Inc. p/n 74-D001, Rev. A...
Cooldown The machine is heated during “preparing” and “print”. Be aware that temperatures inside the machine and the door are elevated and avoid contact with these areas. 3D Systems, Inc. p/n 74-D001, Rev. A...
Page 26
In the refill state, it is possible to fill up the machine with more powder. This is also the state for filter cleaning through the refill hatch which must be done after every refill and after every print job. Error Contact 3D Systems as soon as possible and do not turn off the machine. 3D Systems, Inc. p/n 74-D001, Rev. A...
How to Reach 3D Systems You can learn more about 3D Systems’ warranty, service, updates, and other support by visiting our customer support site at https://support.3dsystems.com. You may also directly contact 3D Systems using the numbers or email addresses below:...
Need help?
Do you have a question about the wematter Gravity and is the answer not in the manual?