xFusion Digital Technologies FusionServer 5288 V7 Manual page 94

Table of Contents

Advertisement

FusionServer 5288 V7 Server
Technical White Paper
PCIe
Riser
Card
● a: PCIe 5.0 refers to the PCIe of the fifth generation, and x16 refers to the
● b: The x16 in brackets indicates that the link bandwidth is x16.
● c: The default link bandwidth of FlexIO card 1 is x8. The link bandwidth can be
● d: FlexIO card 1 supports the Socket Direct function when it is connected to the
● e: The default link bandwidth of FlexIO card 2 is x8. The link bandwidth can be
● f: When the link bandwidth of FlexIO card 1 is x16, the mezzanine RAID
● The PCIe x16 slots are compatible with PCIe x16, PCIe x8, PCIe x4, and PCIe
● The full-height full-length (FHFL) PCIe slots are compatible with FHFL PCIe
● The FHHL PCIe slots are compatible with FHHL PCIe cards and HHHL PCIe
● The maximum power supply of each PCIe slot is 75 W.
Server Bus/Device/Function Number (B/D/F) Information
The server's B/D/F information may change with PCIe card configurations. You can
obtain the B/D/F information of the server using the following methods:
Issue 01 (2023-07-20)
PCIe
Riser
Card
Installati
on
Position
physical slot width.
extended to x16 using cables. The mezzanine RAID controller card cannot be
inserted at this time.
two CPUs through high-speed cables.
extended to x16 using cables. When FlexIO card 1 supports the Socket-Direct
function, FlexIO card 2 can only support x8.
controller card cannot be inserted.
x1 cards. The bandwidth of the PCIe slot cannot be less than that of the
inserted PCIe card.
cards, full-height half-length (FHHL) PCIe cards, and half-height half-length
(HHHL) PCIe cards.
cards.
BIOS serial port log: If the serial port log has been collected, you can query the
B/D/F information of the server by searching for the keyword "dumpiio".
UEFI Shell: You can obtain the B/D/F of the server using the pci command. Run
the help pci command to obtain the specific usage of the pci command.
You can obtain the B/D/F of the server using the pci command. Run the help pci
command to obtain the specific usage of the pci command.
Linux OS: You can obtain the B/D/F information of the server using the lspci
-vvv command.
NO TE
If the OS does not support the lspci command by default, obtain the pci-utils
package from the yum source and install it to make the OS support the command.
Copyright © xFusion Digital Technologies Co., Ltd.
PCIe
PCIe
Slots on
Slot or
the PCIe
Port
Riser
Descripti
Card
on
5 Hardware Description
CPU
PCIe
Port
Number
PCIe
Device
Support
ed by
the PCIe
Slot or
Port
87

Advertisement

Table of Contents
loading