xFusion Digital Technologies FusionServer 5288 V7 Manual page 88

Table of Contents

Advertisement

FusionServer 5288 V7 Server
Technical White Paper
E1.S Drive Indicators
Figure 5-42 E1.S drive indicators
Issue 01 (2023-07-20)
Activity
Indicator
(Green)
Blinking at 4 Hz
Steady on/
blinking
Off
Off
Steady on/Off
If the VMD function is enabled and the latest VMD driver is installed, the E1.S
drive supports surprise hot swap.
Table 5-18 E1.S drive indicator description (VMD function enabled)
Activity
Indicator
(Green)
Off
Steady on
Blinking at 2 Hz
Off
Copyright © xFusion Digital Technologies Co., Ltd.
Fault Indicator
Description
(Red/Blue)
Off
Data is being read from or written to
the NVMe drive.
Blinking blue at 4
The NVMe drive is being located.
Hz
Blinking red at
The NVMe drive has completed the
0.5 Hz
hot swap process and is removable.
Blinking red at 2
The NVMe drive is being hot-
Hz
swapped.
Red steady on
The NVMe drive is faulty.
Fault Indicator
Description
(Yellow)
Off
The E1.S drive is not detected.
Off
The E1.S drive is detected and
operating properly.
Off
Data is being read from or written to
the E1.S drive.
Blinking at 2 Hz
The E1.S drive is being located.
5 Hardware Description