xFusion Digital Technologies FusionServer 1288H V5 Technical Paper

xFusion Digital Technologies FusionServer 1288H V5 Technical Paper

Advertisement

Quick Links

FusionServer 1288H V5 Server
Technical White Paper
Issue
08
Date
2023-02-28
xFusion Digital Technologies Co., Ltd.

Advertisement

Table of Contents
loading

Summary of Contents for xFusion Digital Technologies FusionServer 1288H V5

  • Page 1 FusionServer 1288H V5 Server Technical White Paper Issue Date 2023-02-28 xFusion Digital Technologies Co., Ltd.
  • Page 2 Notice In this document, "xFusion" is used to refer to "xFusion Digital Technologies Co., Ltd." for concise description and easy understanding, which does not mean that "xFusion" may have any other meaning. Any "xFusion" mentioned or described hereof may not be understood as any meaning other than "xFusion Digital Technologies Co., Ltd.", and xFusion Digital Technology Co., Ltd.
  • Page 3: Table Of Contents

    FusionServer 1288H V5 Server Technical White Paper Contents Contents About This Document ......................v 1 Product Introduction ...................... 7 2 Features ........................... 8 3 Physical Structure ......................11 4 Logical Structure ......................12 5 Hardware Description ....................14 5.1 Front Panel ............................14 5.1.1 Appearance ............................14...
  • Page 4 FusionServer 1288H V5 Server Technical White Paper Contents 5.5.1 Drive Configurations ...........................37 5.5.2 Drive Numbering ..........................38 5.5.3 Drive Indicators ..........................39 5.5.4 RAID Controller Card .........................41 5.6 Network ..............................42 5.6.1 LOMs ..............................42 5.6.2 FlexIO Cards ............................44 5.7 I/O Expansion ............................48 5.7.1 PCIe Cards ............................48 5.7.2 PCIe Slots ............................48...
  • Page 5: About This Document

    Technical White Paper About This Document About This Document Purpose This document describes the FusionServer 1288H V5 rack server in terms of features, structure, specifications, and component hardware and software compatibility. Intended Audience This document is intended for pre-sales engineers.
  • Page 6 FusionServer 1288H V5 Server Technical White Paper About This Document Change History Issue Date Description 2023-02-28 Updated 5.7.2 PCIe Slots. 2022-11-30 Updated A.4 Nameplate . 2022-11-11 ⚫ Updated 6.3 Physical Specifications . Updated 8.1 Security. ⚫ 2022-09-08 Updated 5.1.2 Indicators and Buttons.
  • Page 7: Product Introduction

    Technical White Paper 1 Product Introduction Product Introduction FusionServer 1288H V5 (1288H V5) is a new-generation 1U 2-socket rack server designed for Internet, Internet Data Center (IDC), cloud computing, enterprise, and telecom applications. The 1288H V5 is ideal for IT core services, cloud computing, high-performance computing, distributed storage, big data processing, enterprise or telecom applications, and other complex workloads.
  • Page 8: Features

    FusionServer 1288H V5 Server Technical White Paper 2 Features Features Performance and Scalability ® ® ⚫ Powered by two Intel Xeon Scalable Skylake or Cascade Lake processors, the server provides up to 28 cores, 3.8 GHz frequency, a 38.5 MB L3 cache, and two 10.4 GT/s UPI links between the processors, which deliver supreme processing...
  • Page 9 FusionServer 1288H V5 Server Technical White Paper 2 Features ⚫ The use of all solid-state drives (SSDs) is supported. An SSD supports up to 100 times more I/O operations per second (IOPS) than a typical hard disk drive (HDD). The use of all SSDs provides higher I/O performance than the use of all HDDs or a combination of HDDs and SSDs.
  • Page 10 FusionServer 1288H V5 Server Technical White Paper 2 Features ⚫ The following requirements in NIST SP 800-147B are met: The BIOS firmware digital signature update mechanism is supported. During − the upgrade, the digital signature is verified to prevent unauthorized BIOS firmware upgrade.
  • Page 11: Physical Structure

    FusionServer 1288H V5 Server Technical White Paper 3 Physical Structure Physical Structure Figure 3-1 1288H V5 physical structure (example: 8 x 2.5" drives) Power supply unit (PSU) Chassis Fan module bracket Fan module Front drive backplane Drive DVD drive Indicator board...
  • Page 12: Logical Structure

    FusionServer 1288H V5 Server Technical White Paper 4 Logical Structure Logical Structure Figure 4-1 1288H V5 logical structure ® ® ⚫ The server supports one or two Intel Xeon Scalable processors. ⚫ The server supports up to 24 memory modules.
  • Page 13 FusionServer 1288H V5 Server Technical White Paper 4 Logical Structure ⚫ Uses the BMC management chip, and supports a VGA, a management network port, a debugging serial port, and other management ports. ⚫ The BMC management chip can be an enhanced management chip (VB) or an ordinary management chip.
  • Page 14: Hardware Description

    FusionServer 1288H V5 Server Technical White Paper 5 Hardware Description Hardware Description 5.1 Front Panel 5.2 Rear Panel 5.3 Processor 5.4 Memory 5.5 Storage 5.6 Network 5.7 I/O Expansion 5.8 PSUs 5.9 Fans 5.10 Boards 5.1 Front Panel 5.1.1 Appearance ⚫...
  • Page 15: Indicators And Buttons

    FusionServer 1288H V5 Server Technical White Paper 5 Hardware Description Figure 5-2 Front view Drives (Optional) Built-in DVD drive Slide-out label plate (with an SN label) ⚫ 10 x 2.5" drive configuration Figure 5-3 Front view Drives Slide-out label plate (with an SN label) 5.1.2 Indicators and Buttons...
  • Page 16 FusionServer 1288H V5 Server Technical White Paper 5 Hardware Description Non-Maskable Interrupt Reserve (NMI) button Power button/indicator UID button/indicator ⚫ 8 x 2.5" drive configuration Figure 5-5 Indicators and buttons on the front panel Fault diagnosis LED Health status indicator...
  • Page 17 FusionServer 1288H V5 Server Technical White Paper 5 Hardware Description Indicator and Button Descriptions Table 5-1 Description of indicators and buttons on the front panel Sign Indicator and Description Button Fault ⚫ ---: The device is operating properly. diagnosis LED ⚫...
  • Page 18: Ports

    FusionServer 1288H V5 Server Technical White Paper 5 Hardware Description Indicator and Sign Description Button Health status Off: The device is powered off or is faulty. ⚫ indicator Blinking red at 1 Hz: A major alarm has been ⚫ generated on the system.
  • Page 19 FusionServer 1288H V5 Server Technical White Paper 5 Hardware Description Figure 5-8 Ports on the front panel USB 2.0 port USB 3.0 port VGA port ⚫ 10 x 2.5" drive configuration Figure 5-9 Ports on the front panel USB 3.0 port...
  • Page 20: Rear Panel

    FusionServer 1288H V5 Server Technical White Paper 5 Hardware Description 5.2 Rear Panel 5.2.1 Appearance Figure 5-10 Rear view PCIe slot 1 PCIe slot 2 PCIe slot 3 (Optional) FlexIO card PSU 1 PSU 2 5.2.2 Indicators Indicator Positions Figure 5-11 Indicators on the rear panel...
  • Page 21 FusionServer 1288H V5 Server Technical White Paper 5 Hardware Description Indicator Description Table 5-3 Description of indicators on the rear panel Indicator Description LOM port indicator For details, see 5.6.1 LOMs . PSU indicator ⚫ Off: No power is supplied.
  • Page 22: Ports

    FusionServer 1288H V5 Server Technical White Paper 5 Hardware Description 5.2.3 Ports Port Positions Figure 5-12 Ports on the rear panel LOM port 1 VGA port LOM port 2 Management network port Serial port USB 3.0 port PSU socket Port Description...
  • Page 23: Processor

    FusionServer 1288H V5 Server Technical White Paper 5 Hardware Description Tool Type Quantity Description default baud rate is 115,200 bit/s. Management 1000BASE-T Used for server management. network port NOTE The management network port is a GE port that supports 100 Mbit/s and 1000 Mbit/s auto-negotiation.
  • Page 24: Memory

    FusionServer 1288H V5 Server Technical White Paper 5 Hardware Description Figure 5-13 Processor positions 5.4 Memory 5.4.1 DDR4 Memory 5.4.1.1 Memory Identifier You can determine the memory module properties based on the label attached to the memory module. 2023-02-28...
  • Page 25 FusionServer 1288H V5 Server Technical White Paper 5 Hardware Description Figure 5-14 Memory identifier Callout Description Definition Capacity of the memory module ⚫ 8 GB 16 GB ⚫ ⚫ 32 GB 64 GB ⚫ ⚫ 128 GB Number of ranks of the memory 1R: single-rank ⚫...
  • Page 26: Memory Subsystem Architecture

    FusionServer 1288H V5 Server Technical White Paper 5 Hardware Description 5.4.1.2 Memory Subsystem Architecture The 1288H V5 provides 24 memory slots. Each processor integrates six memory channels. Install the memory modules in the primary memory channels first. If the primary memory channel is not populated, the memory modules in secondary memory channels cannot be used.
  • Page 27: Memory Compatibility

    FusionServer 1288H V5 Server Technical White Paper 5 Hardware Description 5.4.1.3 Memory Compatibility Observe the following rules when configuring DDR4 DIMMs: ⚫ A server must use the same model of DDR4 DIMMs, and all the DIMMs operate at the same speed, which is the smallest value of: ⚫...
  • Page 28: Dimm Installation Rules

    FusionServer 1288H V5 Server Technical White Paper 5 Hardware Description A quad-rank LRDIMM generates the same electrical load as a single-rank RDIMM on a memory bus. Table 5-6 DDR4 memory specifications Parameter Specifications Maximum capacity per DDR4 DIMM (GB) Rated speed (MT/s)
  • Page 29: Memory Installation Positions

    FusionServer 1288H V5 Server Technical White Paper 5 Hardware Description The channels can have different online spare configurations. ◼ Each populated channel must have a spare rank. ◼ Memory mirroring mode − Comply with the general installation guidelines. ◼ Each processor supports two integrated memory controllers (IMCs). At ◼...
  • Page 30: Memory Protection Technologies

    FusionServer 1288H V5 Server Technical White Paper 5 Hardware Description Figure 5-16 DDR4 memory installation guidelines (1 processor) Figure 5-17 DDR4 memory installation guidelines (2 processors) 5.4.1.6 Memory Protection Technologies The following memory protection technologies are supported: ⚫ ⚫ Full mirroring ⚫...
  • Page 31: Dcpmm

    FusionServer 1288H V5 Server Technical White Paper 5 Hardware Description ⚫ Rank sparing mode ⚫ Static virtual lockstep ⚫ Faulty DIMM isolation ⚫ Memory thermal throttling ⚫ Memory address parity protection ⚫ Memory demand/patrol scrubbing ⚫ Device tagging ⚫ Data scrambling ⚫...
  • Page 32: Memory Subsystem Architecture

    FusionServer 1288H V5 Server Technical White Paper 5 Hardware Description Callout Description Example SN QR code 8089-A2-1839-00001931 5.4.2.2 Memory Subsystem Architecture The 1288H V5 provides 24 memory slots. Each processor integrates six memory channels, and each memory channel supports up to one DCPMM.
  • Page 33: Memory Compatibility

    FusionServer 1288H V5 Server Technical White Paper 5 Hardware Description Memory Channel Memory Slot F (primary) DIMM150(F) DIMM151(L) 5.4.2.3 Memory Compatibility Observe the following rules when configuring DC persistent memory modules (DCPMMs): ⚫ The DCPMMs must be used with the DDR4 memory modules. For details, see the FusionServer DCPMM User Guide.
  • Page 34: Dimm Installation Rules

    FusionServer 1288H V5 Server Technical White Paper 5 Hardware Description Item Specifications Capacity per DCPMM (GB) Rated speed (MT/s) 2666 2666 2666 Operating voltage (V) Maximum number of DCPMMs in a server Maximum capacity of the server 2304 4608 7680...
  • Page 35: Memory Installation Positions

    FusionServer 1288H V5 Server Technical White Paper 5 Hardware Description Maximum Memory Capacity Supported by a CPU (DDR4 and CPU Type DCPMM Capacities) M series 2 TB L series 4.5 TB 5.4.2.5 Memory Installation Positions A 1288H V5 supports a maximum of 12 DCPMMs. The DCPMMs must be used with DDR4 DIMMs.
  • Page 36: Memory Protection Technologies

    FusionServer 1288H V5 Server Technical White Paper 5 Hardware Description Figure 5-21 DCPMM and DDR4 memory configuration guidelines (2 processors) Figure 5-22 DCPMM and DDR4 memory configuration guidelines 5.4.2.6 Memory Protection Technologies The following memory protection technologies are supported: ⚫...
  • Page 37: Storage

    FusionServer 1288H V5 Server Technical White Paper 5 Hardware Description ⚫ DCPMM DDR-T fault tolerance ⚫ Faulty DCPMM isolation 5.5 Storage 5.5.1 Drive Configurations Table 5-10 Drive Configuration Configuration Maximum Front Hard Drive Management Disks Mode 4 x 3.5" drive ⚫...
  • Page 38: Drive Numbering

    FusionServer 1288H V5 Server Technical White Paper 5 Hardware Description Maximum Front Hard Drive Management Configuration Disks Mode drives. slot 1. 10 x 2.5" drive Front drive: 10 x 2.5 1 x RAID controller ⚫ configuration 3 card/PCH Slots 0 to 5 support −...
  • Page 39: Drive Indicators

    FusionServer 1288H V5 Server Technical White Paper 5 Hardware Description Table 5-11 SATA drive numbers Drive No. ATA No. ATA3 ATA4 ATA5 ATA6 ATA7 ATA8 ATA9 ATA10 ⚫ 10 x 2.5" drive configuration Figure 5-25 Drive numbering 5.5.3 Drive Indicators...
  • Page 40 FusionServer 1288H V5 Server Technical White Paper 5 Hardware Description Activity Indicator Fault Indicator Description (Green) (Yellow) Blinking at 4 Hz Data is being read or written normally, or data on the primary drive is being rebuilt. Steady on Blinking at 1 Hz The drive is being located.
  • Page 41: Raid Controller Card

    FusionServer 1288H V5 Server Technical White Paper 5 Hardware Description Table 5-14 NVMe drive indicators (VMD disabled) Activity Indicator Fault Indicator Description (Green) (Yellow) The NVMe drive cannot be detected. Steady on The NVMe drive is working properly. Blinking at 2 Hz Data is being read from or written to the NVMe drive.
  • Page 42: Network

    FusionServer 1288H V5 Server Technical White Paper 5 Hardware Description ⚫ Contact your local sales representative or use the Compatibility Checker determine the components to be used. ⚫ For details about the RAID controller card, see V5 Server RAID Controller Card User Guide.
  • Page 43 FusionServer 1288H V5 Server Technical White Paper 5 Hardware Description Figure 5-29 LOM port (Optional) 10GE optical (Optional) 10GE optical port (LOM port 1) port (LOM port 2) (Optional) 10GE electrical (Optional) 10GE electrical port (LOM port 1) port (LOM port 2)
  • Page 44: Flexio Cards

    FusionServer 1288H V5 Server Technical White Paper 5 Hardware Description Indicator Description Table 5-17 LOM indicators Indicator Description Connection status ⚫ Off: The network port is not connected. indicator/Data Blinking green: Data is being transmitted. ⚫ transmission status Steady green: The network port is properly connected.
  • Page 45 FusionServer 1288H V5 Server Technical White Paper 5 Hardware Description Table 5-18 FlexIO cards supported by the 1288H V5 (example) NIC Model Chip Model Port Type Number of Support Ports NC-SI/WOL/P √ SM210 5719 GE electrical port √ SM211 i350...
  • Page 46 FusionServer 1288H V5 Server Technical White Paper 5 Hardware Description ⚫ SM233 with two 10GE electrical ports Figure 5-33 SM233 network port indicators ⚫ SM251 with two 56G IB optical ports Figure 5-34 SM251 network port indicators ⚫ SM252 with one 56G IB optical port Figure 5-35 SM252 network port indicators ⚫...
  • Page 47 FusionServer 1288H V5 Server Technical White Paper 5 Hardware Description Port Type Indicator Description Connection status Off: The network port is not ⚫ indicators connected. Steady green: The network port is ⚫ properly connected. 10GE electrical Transmission rate Off: The data transmission rate is ⚫...
  • Page 48: I/O Expansion

    FusionServer 1288H V5 Server Technical White Paper 5 Hardware Description Port Type Indicator Description abnormal. ⚫ Steady green: The physical link is normal. Data transmission ⚫ Off: No logical link is set up. status indicator ⚫ Blinking yellow: Data is being transmitted.
  • Page 49: Pcie Slot Description

    FusionServer 1288H V5 Server Technical White Paper 5 Hardware Description PCIe Riser Modules Figure 5-38 PCIe riser modules 5.7.3 PCIe Slot Description The PCIe slots mapping to a vacant CPU socket are unavailable. 2023-02-28...
  • Page 50: Psus

    FusionServer 1288H V5 Server Technical White Paper 5 Hardware Description Table 5-20 PCIe slot description PCIe PCIe Conne Port Root Devic Slot Slot Stand ctor Width Port Size ards Width (B/D/F (B/D/F RAID CPU 1 PCIe Port1C 17/02/ 1D/00/ control...
  • Page 51: Fans

    FusionServer 1288H V5 Server Technical White Paper 5 Hardware Description ⚫ The server supports two PSUs in 1+1 redundancy. ⚫ The same model of PSUs must be used in a server. ⚫ The PSUs are protected against short circuit. Double-pole fuse is provided for the PSUs with dual input live wires.
  • Page 52: Boards

    FusionServer 1288H V5 Server Technical White Paper 5 Hardware Description Figure 5-40 Fan module positions 5.10 Boards 5.10.1 Mainboard ⚫ BOM code for mainboards of enhanced management chip (VB): 0302Y074, 0302Y075. BOM code for mainboards of normal management chip: 03024AFS, 03029JRW, 03024CXR, ⚫...
  • Page 53 FusionServer 1288H V5 Server Technical White Paper 5 Hardware Description Figure 5-41 1288H V5 mainboard (BOM: 03024AFS, 03029JRW, 03024CXR, 03029JRV, 0302Y074, 0302Y075, 06410417, 06410421) USB 3.0 port (USB 3.0 UID indicator (D6020) CONN/J169) Serial port Management network port GE electrical port...
  • Page 54 FusionServer 1288H V5 Server Technical White Paper 5 Hardware Description PCIe riser 1 slot SATA signal connector 2 (corresponding to CPU (SATA2/J71) 1/J108) SATA signal connector 1 Mini SAS HD connector B (SATA1/J67) (MINIHD PORT B/J84) Mini SAS HD connector A USB 3.0 port (FRONT...
  • Page 55: Drive Backplane

    FusionServer 1288H V5 Server Technical White Paper 5 Hardware Description 5.10.2 Drive Backplane ⚫ 4 x 3.5" drive backplane (4 x SAS/SATA) Figure 5-42 4 x 3.5" drive backplane (4 x SAS/SATA) (BOM: 03024NKB, 03029WEX) Backplane indicator signal SATA signal connector...
  • Page 56 FusionServer 1288H V5 Server Technical White Paper 5 Hardware Description Figure 5-44 10 x 2.5" drive backplane 1 (BOM: 03024AGB) mini-SAS HD connector mini-SAS HD connector (PORT 3/J7) (PORT 2/J6) mini-SAS HD connector mini-SAS HD connector (PORT 0/J4) (PORT 1/J5)
  • Page 57: Product Specifications

    FusionServer 1288H V5 Server Technical White Paper 6 Product Specifications Product Specifications 6.1 Technical Specifications 6.2 Environmental Specifications 6.3 Physical Specifications 6.1 Technical Specifications Table 6-1 Technical Specifications Component Specifications Form factor 1U rack server ® Chipset Intel C622 Processor Supports one or two processors.
  • Page 58 FusionServer 1288H V5 Server Technical White Paper 6 Product Specifications Component Specifications RDIMM and LRDIMM support − The DDR4 memory modules of different types − (RDIMM and LRDIMM) and specifications (capacity, bit width, rank, and height) cannot be used together.
  • Page 59 FusionServer 1288H V5 Server Technical White Paper 6 Product Specifications Component Specifications Supports hot swap of SAS/SATA/NVMe U.2 drives. ⚫ NOTE The NVMe drives support: ⚫ Surprise hot swap if the VMD function is enabled and the latest Intel VMD driver is installed.
  • Page 60 FusionServer 1288H V5 Server Technical White Paper 6 Product Specifications Component Specifications I/O expansion 5 PCIe 3.0 slots: ⚫ One slot dedicated for a screw-in RAID controller card, one dedicated for a FlexIO card, and three for standard PCIe cards.
  • Page 61: Environmental Specifications

    FusionServer 1288H V5 Server Technical White Paper 6 Product Specifications Component Specifications resolution (1920 x 1200) only after the video card driver matching the operating system version is installed. Otherwise, only the default resolution supported by the operating system is provided.
  • Page 62 FusionServer 1288H V5 Server Technical White Paper 6 Product Specifications Category Specifications Maximum change rate: 20%/h ⚫ ≥ 96 cubic feet per minute (CFM) Air volume ≤3050m Operating altitude When the server configuration complies with ASHRAE ⚫ Classes A1 and A2 and the altitude is above 900 m (2952.76 ft), the highest operating temperature...
  • Page 63: Physical Specifications

    FusionServer 1288H V5 Server Technical White Paper 6 Product Specifications SSDs and HDDs (including NL-SAS, SAS, and SATA) cannot be preserved for a long time in the power-off state. Data may be lost or faults may occur if the preservation duration exceeds the specified maximum duration.
  • Page 64 FusionServer 1288H V5 Server Technical White Paper 6 Product Specifications Item Description Installation dimension Requirements for cabinet installation: ⚫ requirements 19-inch standard cabinet compliant with the International Electrotechnical Commission (IEC) 297 standard − Cabinet width: 482.6 mm (19.00 in.) Cabinet depth ≥ 1000 mm (39.37 in.) −...
  • Page 65: Software And Hardware Compatibility

    FusionServer 1288H V5 Server Technical White Paper 7 Software and Hardware Compatibility Software and Hardware Compatibility Use the Compatibility Checker to obtain information about the operating systems and hardware supported. ⚫ If incompatible components are used, the device may be abnormal. This fault is beyond the scope of technical support and warranty.
  • Page 66: Safety Instructions

    FusionServer 1288H V5 Server Technical White Paper 8 Safety Instructions Safety Instructions 8.1 Security 8.2 Maintenance and Warranty 8.1 Security General Statement ⚫ Comply with local laws and regulations when installing devices. These Safety Instructions are only a supplement. ⚫...
  • Page 67 FusionServer 1288H V5 Server Technical White Paper 8 Safety Instructions ⚫ Do not carry the weight that is over the maximum load per person allowed by local laws or regulations. Before moving or installing equipment, check the maximum equipment weight and arrange required personnel.
  • Page 68 FusionServer 1288H V5 Server Technical White Paper 8 Safety Instructions Figure 8-3 Wearing an ESD wrist strap ⚫ Exercise caution when using tools. ⚫ If the installation position of the device is higher than the shoulders of the installation personnel, use a vehicle such as a lift to facilitate installation. Prevent the equipment from falling down and causing personal injury or damage to the equipment.
  • Page 69: Maintenance And Warranty

    FusionServer 1288H V5 Server Technical White Paper 8 Safety Instructions equipment being transported is always kept upright. Take necessary precautions to prevent collisions, corrosion, package damage, damp conditions and pollution. ⚫ Transport the equipment in its original packaging. ⚫ If the original packaging is unavailable, package heavy, bulky parts (such as chassis and blades) and fragile parts (such as PCIe GPUs and SSDs) separately.
  • Page 70: System Management

    FusionServer 1288H V5 Server Technical White Paper 9 System Management System Management The server uses the next-generation Intelligent Baseboard Management Controller (iBMC) to implement remote server management. The iBMC complies with IPMI 2.0 and provides highly reliable hardware monitoring and management.
  • Page 71 FusionServer 1288H V5 Server Technical White Paper 9 System Management Specifications Description Setting of boot device Supports out-of-band configuration for the boot device. Alarm management Supports alarm management and reports alarms using the SNMP trap, SMTP, and syslog service to ensure 24/7 operating.
  • Page 72: Certifications

    FusionServer 1288H V5 Server Technical White Paper 10 Certifications Certifications Country/Region Certification Standards Europe WEEE 2012/19/EU Europe REACH EC NO. 1907/2006 Europe Safety: EN 62368-1:2014+A11:2017 EMC: EN 55032:2015+A11:2020 CISPR 32:2015+A1:2019 EN IEC 61000-3-2:2019+A1:2021 EN 61000-3-3:2013+A1:2019 EN 55035:2017+A11:2020 CISPR 35:2016 EN 55024:2010+A1:2015 CISPR 24:2010+A1:2015 ETSI EN 300 386 V1.6.1:2012...
  • Page 73 FusionServer 1288H V5 Server Technical White Paper 10 Certifications Country/Region Certification Standards EN 55032:2015+A11:2020 CISPR 32:2015+A1:2019 EN IEC 61000-3-2:2019+A1:2021 EN 61000-3-3:2013+A1:2019 EN 55035:2017+A11:2020 CISPR 35:2016 EN 55024:2010+A1:2015 CISPR 24:2010+A1:2015 ETSI EN 300 386 V1.6.1:2012 ETSI EN 300 386 V2.1.1:2016 RoHS:...
  • Page 74: A Appendix

    FusionServer 1288H V5 Server Technical White Paper A Appendix Appendix A.1 Chassis Label The label information and location are for reference only. For details, see the actual product. A.1.1 On the Front Top Figure A-1 Chassis head label Nameplate Certificate...
  • Page 75 FusionServer 1288H V5 Server Technical White Paper A Appendix A.1.1.1 Nameplate Figure A-2 Nameplate example Table A-1 Nameplate description Description Server Model For details, see A.4 Nameplate . Device names Power Supply Requirements Vendor Information Authentication ID A.1.1.2 Certificate Figure A-3 Sample certificate...
  • Page 76 FusionServer 1288H V5 Server Technical White Paper A Appendix Table A-2 Certificate description Description Order NOTE For details, see Figure A-4 and Table A-3. QC inspector Production date No. Barcode Figure A-4 Sample certificate No. Table A-3 Certificate No. Description Description The value for this digit is P, which is fixed.
  • Page 77 FusionServer 1288H V5 Server Technical White Paper A Appendix Description Letters A to H indicate 10:00 to 17:00. ⚫ ⚫ Letters J to N indicate 18:00 to 22:00. Letters P to Q indicate 23:00 to 24:00. ⚫ Indicates the serial number (two digits).
  • Page 78 FusionServer 1288H V5 Server Technical White Paper A Appendix A.1.2 Chassis Tail Label Figure A-6 Chassis tail label For details about the warning label, see Server Safety Information. A.1.3 Chassis Internal Label Figure A-7 Chassis internal label ⚫ The quick guide is located on the inside of the chassis cover. It describes how to remove the mainboard components, important components of the chassis, precautions, and QR codes of technical resources.
  • Page 79 FusionServer 1288H V5 Server Technical White Paper A Appendix Figure A-8 Example SN Table A-5 SN description Description ESN ID (two characters), which can only be 21. Material ID (eight characters), that is, the processing code. Vendor code (two characters), that is, the code of the processing place.
  • Page 80 FusionServer 1288H V5 Server Technical White Paper A Appendix Configuratio Max. 35° C (95° F) Max. 40° C (104° F) Max. 45° C (113° F) 8280L/8280M/82 5118/5215, 68 and Gold Silver 6154/6254 4216/4215/4214, processors and other processors lower PCIe SSD cards ⚫...
  • Page 81 FusionServer 1288H V5 Server Technical White Paper A Appendix A.4 Nameplate Certified Model Usage Restrictions H12H-05 Global A.5 RAS Features The server supports a variety of Reliability, Availability, and Serviceability (RAS) features. You can configure these features for better performance.
  • Page 82 FusionServer 1288H V5 Server Technical White Paper A Appendix Module Feature Description PCIe PCIe Advanced Error Provides a PCIe advanced error Reporting reporting mechanism to improve server serviceability. Intel UPI Link Level Retry Provides a retry mechanism to improve the reliability of UPI links.
  • Page 83 FusionServer 1288H V5 Server Technical White Paper A Appendix Module Feature Description Failure Analysis (PFA) provides information about physical memory error units. The OS tracks, predicts, and handles the errors. A.6 Sensor List Sensor Description Component Inlet Temp Air inlet temperature...
  • Page 84 FusionServer 1288H V5 Server Technical White Paper A Appendix Sensor Description Component CPUN VCore 1.8 V CPU voltage Mainboard N indicates the CPU number. The value is 1 or CPUN DDR VDDQ 1.2 V DIMM voltage Mainboard N indicates the CPU number.
  • Page 85 FusionServer 1288H V5 Server Technical White Paper A Appendix Sensor Description Component value ranges from 1 to 7. Power Server input power PSN VIN Input voltage PSUN N indicates the PSU number. The value is 1 or Disks Temp Drive maximum...
  • Page 86 FusionServer 1288H V5 Server Technical White Paper A Appendix Sensor Description Component the voltage is lower than 1 PCIE Status PCIe status PCIe card Power Button Power button pressed Mainboard and power state button Watchdog2 Watchdog Mainboard Mngmnt Health Management subsystem...
  • Page 87 FusionServer 1288H V5 Server Technical White Paper A Appendix Sensor Description Component N indicates the PSU PSN Fan Status PSU fan status number. The value is 1 or PSN Temp Status PSU presence DISKN Drive status Drive N N indicates the drive slot number.
  • Page 88: B Glossary

    FusionServer 1288H V5 Server Technical White Paper B Glossary Glossary B.1 A-E ejector lever A part on the panel of a device used to facilitate installation or removal of the device. Ethernet A baseband local area network (LAN) architecture developed by Xerox Corporation by partnering with Intel and DEC.
  • Page 89 FusionServer 1288H V5 Server Technical White Paper B Glossary B.3 K-O A hardware device that provides public keyboard, video and mouse (KVM). B.4 P-T panel An external component (including but not limited to ejector levers, indicators, and ports) on the front or rear of the server.
  • Page 90 FusionServer 1288H V5 Server Technical White Paper B Glossary B.5 U-Z A unit defined in International Electrotechnical Commission (IEC) 60297-1 to measure the height of a cabinet or chassis. 1 U = 44.45 mm UltraPath A point-to-point processor interconnect developed by Interconnect (UPI) Intel.
  • Page 91: C Acronyms And Abbreviations

    FusionServer 1288H V5 Server Technical White Paper C Acronyms and Abbreviations Acronyms and Abbreviations C.1 A-E alternating current Advanced Encryption Standard New Instruction Set Address Resolution Protocol Advanced Vector Extensions backup battery unit BIOS Basic Input/Output System calendar day Conformite Europeenne...
  • Page 92 FusionServer 1288H V5 Server Technical White Paper C Acronyms and Abbreviations DDR3 Double Data Rate 3 DDR4 Double Data Rate 4 DDDC double device data correction DEMT Dynamic Energy Management Technology DIMM dual in-line memory module DRAM dynamic random-access memory...
  • Page 93 FusionServer 1288H V5 Server Technical White Paper C Acronyms and Abbreviations high availability hard disk drive high-performance computing HTTP Hypertext Transfer Protocol HTTPS Hypertext Transfer Protocol Secure iBMC intelligent baseboard management controller Industry Canada ICMP Internet Control Message Protocol Internet Data Center...
  • Page 94 FusionServer 1288H V5 Server Technical White Paper C Acronyms and Abbreviations LAN on motherboard media access control module management controller next business day NC-SI Network Controller Sideband Interface C.4 P-T PCIe Peripheral Component Interconnect Express power distribution unit physical layer...
  • Page 95 FusionServer 1288H V5 Server Technical White Paper C Acronyms and Abbreviations RJ45 registered jack 45 RoHS Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Serial Attached Small Computer System Interface SATA Serial Advanced Technology Attachment...
  • Page 96 FusionServer 1288H V5 Server Technical White Paper C Acronyms and Abbreviations TCP offload engine trusted platform module C.5 U-Z UDIMM unbuffered dual in-line memory module UEFI Unified Extensible Firmware Interface unit identification light Underwriter Laboratories Inc. Universal Serial Bus VCCI...

Table of Contents