  • Page 1 FusionServer 2488H V6 Server Technical White Paper Issue Date 2022-08-12 xFusion Digital Technologies Co., Ltd.
  • Page 2 Notice In this document, "xFusion" is used to refer to "xFusion Digital Technologies Co., Ltd." for concise description and easy understanding, which does not mean that "xFusion" may have any other meaning. Any "xFusion" mentioned or described hereof may not be understood as any meaning other than "xFusion Digital Technologies Co., Ltd.", and xFusion Digital Technology Co., Ltd.
  • Page 3: Table Of Contents

    FusionServer 2488H V6 Server Technical White Paper Contents Contents About This Document ........................v 1 Overview ............................7 2 Features ............................8 3 Physical Structure ........................11 4 Logical Structure ......................... 13 5 Hardware Description ........................ 14 5.1 Front Panel .................................. 14 5.1.1 Appearance ................................
  • Page 4 FusionServer 2488H V6 Server Technical White Paper Contents 5.5 Storage ..................................46 5.5.1 Drive Configurations ............................... 46 5.5.2 Drive Numbering ..............................52 5.5.3 Drive Indicators ............................... 57 5.5.4 RAID Controller Card ............................. 59 5.6 Network ..................................60 5.6.1 OCP 3.0 Network Adapter ............................60 5.7 I/O Expansion ................................
  • Page 5: About This Document

    Technical White Paper About This Document About This Document Purpose This document describes the FusionServer 2488H V6 rack server in terms of features, structure, specifications, and component hardware and software compatibility. Intended Audience This document is intended for pre-sales engineers.
  • Page 6 FusionServer 2488H V6 Server Technical White Paper About This Document Change History Issue Release Date Change Description 2022-08-12 Optimized 6.3 Physical Specifications . ⚫ 2022-06-25 Added a figure that shows how to measure dimensions. ⚫ Added A.1 Chassis Label. ⚫...
  • Page 7: Overview

    1 Overview Overview FusionServer 2488H V6 (2488H V6) is a 2U 4-socket rack server developed for Internet data center (IDC), cloud computing, enterprise, and telecom service applications. The 2488H V6 is ideal for applications such as databases, cloud computing, virtualization, in-memory computing, and deep learning.
  • Page 8: Features

    FusionServer 2488H V6 Server Technical White Paper 2 Features Features Performance and Scalability ⚫ ® ® Powered by the third-generation Intel Xeon Scalable Cooper Lake processors, the server provides up to 28 physical cores, 3.9 GHz frequency, a 38.5 MB L3 cache, and six 10.4 GT/s UPI links between the processors, which deliver supreme processing...
  • Page 9 FusionServer 2488H V6 Server Technical White Paper 2 Features ⚫ Flexible drive configurations meet a variety of business requirements and ensure high elasticity and scalability of storage resources. ⚫ The use of all solid-state drives (SSDs) is supported. An SSD supports up to 100 times more I/O operations per second (IOPS) than a typical hard disk drive (HDD).
  • Page 10 FusionServer 2488H V6 Server Technical White Paper 2 Features ⚫ Intel Execute Disable Bit (EDB) function prevents certain types of malicious buffer overflow attacks when working with a supported OS. ⚫ The Intel Converged Boot Guard & Trusted Execution Technology (Intel CBnT) prevents malicious software attacks based on hardware, prevents the firmware from being maliciously modified, and prevents the execution of unauthorized boot blocks.
  • Page 11: Physical Structure

    FusionServer 2488H V6 Server Technical White Paper 3 Physical Structure Physical Structure Figure 3-1 Physical structure of a server with 8 x 2.5" drives (example) PCIe riser module 1 PCIe card PCIe riser module 2 Power supply unit (PSU) 2022-08-12...
  • Page 12 FusionServer 2488H V6 Server Technical White Paper 3 Physical Structure PSU backplane Chassis Supercapacitor Intrusion sensor Primary air duct Secondary air ducts Drive backplane Left mounting ear plate Drive Fan module bracket Fan module Right mounting ear plate Processor Processor heat sink Cable organizer M.2 SSD...
  • Page 13: Logical Structure

    FusionServer 2488H V6 Server Technical White Paper 4 Logical Structure Logical Structure Figure 4-1 2488H V6 logical structure ⚫ ® ® The server supports two or four third-generation Intel Xeon Scalable processors. ⚫ The server supports up to 48 memory modules.
  • Page 14: Hardware Description

    FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description Hardware Description 5.1 Front Panel 5.2 Rear Panel 5.3 Processors 5.4 Memory 5.5 Storage 5.6 Network 5.7 I/O Expansion 5.8 PSUs 5.9 Fan Modules 5.10 LCD 5.11 Boards 5.1 Front Panel 5.1.1 Appearance...
  • Page 15 FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description Figure 5-1 Front view SAS/SATA drive (Optional) Built-in DVD drive (or LCD module) Slide-out label plate (with an SN label) ⚫ 12 x 2.5" drive pass-through configuration (4 x SAS/SATA + 8 x NVMe)
  • Page 16 FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description Figure 5-3 Front view SAS/SATA drive NVMe SSDs Filler panel in drive slot Slide-out label plate (with an SN label) NOTE The slot cannot hold drives. ⚫ 24 x 2.5" drive pass-through configuration (24 x SAS/SATA)
  • Page 17: Indicators And Buttons

    FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description Figure 5-5 Front view SAS/SATA drive Slide-out label plate (with an SN label) 5.1.2 Indicators and Buttons ⚫ 8 x 2.5" drive pass-through configuration (8 x SAS/SATA) Figure 5-6 Indicators and buttons on the front panel...
  • Page 18 FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description Fault diagnosis LED Power button/indicator Health status indicator UID button/indicator FlexIO card presence iBMC direct connect indicator management port indicator ⚫ 20 x 2.5" drive pass-through configuration (4 x SAS/SATA + 16 x NVMe)
  • Page 19 FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description Figure 5-10 Indicators and buttons on the front panel Fault diagnosis LED Power button/indicator Health status indicator UID button/indicator FlexIO card presence iBMC direct connect indicator management port indicator Indicator and Button Descriptions...
  • Page 20: Ports

    FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description Silkscreen Indicator and Description Button ⚫ Health status Off: The device is powered off or is faulty. indicator ⚫ Blinking red at 1 Hz: A major alarm has been generated on the system.
  • Page 21 FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description Figure 5-11 Ports on the front panel USB 3.0 ports iBMC direct connect management port VGA port ⚫ 12 x 2.5" drive pass-through configuration (4 x SAS/SATA + 8 x NVMe) Figure 5-12 Ports on the front panel USB 3.0 port...
  • Page 22 FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description ⚫ 24 x 2.5" drive pass-through configuration (24 x SAS/SATA) Figure 5-14 Ports on the front panel USB 3.0 port iBMC direct connect management port VGA port ⚫ 25 x 2.5" drive EXP configuration (25 x SAS/SATA) Figure 5-15 Ports on the front panel USB 3.0 port...
  • Page 23: Rear Panel

    FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description Port Type Quantity Description protocol is port NOTE supported. Only local PCs running Windows 10 are supported. ⚫ To log in to the iBMC from the local PC, enter https://IP address...
  • Page 24: Indicators And Buttons

    FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description PCIe Slot6 PCIe Slot7 PCIe Slot8 PCIe Slot9 PCIe riser module 2 Power supply 2 PSU 1 (Optional) FlexIO card NOTE The FlexIO card slot supports only OCP 3.0 network adapters.
  • Page 25 FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description Indicator Description Table 5-3 Indicators on the rear panel Silkscreen Indicator Description FlexIO card status FlexIO cards support only orderly hot swap. indicator For details, see Table 5-4. FlexIO card power FlexIO cards support only orderly hot swap.
  • Page 26: Ports

    FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description Silkscreen Indicator Description ⚫ Steady orange: The input is normal but there is no output. NOTE The possible causes of no power output are as follows: ⚫ Power supply overtemperature protection ⚫...
  • Page 27 FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description VGA port USB 3.0 ports Socket for PSU 1 Socket for PSU 2 Port Description Table 5-5 Ports on the rear panel Port Type Quantity Description Management RJ45 iBMC management network port,...
  • Page 28: Processors

    FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description Port Type Quantity Description that the rated power of the PSUs is greater than that of the server. 5.3 Processors ⚫ The server supports two or four processors. ⚫ If two processors are required, install them in sockets CPU1 and CPU2.
  • Page 29: Memory Subsystem Architecture

    FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description Figure 5-20 Memory identifier Callout Description Example Capacity ⚫ 16 GB ⚫ 32 GB ⚫ 64 GB ⚫ 128 GB ⚫ Number of ranks 1R: single-rank ⚫ 2R: dual-rank ⚫...
  • Page 30 FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description Table 5-6 Memory channels Memory Channel Memory Slot CPU 1 A (primary) DIMM000(A) DIMM001(G) B (primary) DIMM010(B) DIMM011(H) C (primary) DIMM020(C) DIMM021(I) D (primary) DIMM030(D) DIMM031(J) E (primary) DIMM040(E) DIMM041(K)
  • Page 31: Memory Compatibility

    FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description Memory Channel Memory Slot D (primary) DIMM230(D) DIMM231(J) E (primary) DIMM240(E) DIMM241(K) F (primary) DIMM250(F) DIMM251(L) CPU 4 A (primary) DIMM300(A) DIMM301(G) B (primary) DIMM310(B) DIMM311(H) C (primary) DIMM320(C) DIMM321(I)
  • Page 32 FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description ⚫ A server must use DDR4 memory modules of the same part number (P/N code), and the memory speed is the minimum value of the following items: ⚫ Memory speed supported by a CPU ⚫...
  • Page 33: Memory Installation Guidelines

    FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description Parameter Specifications capacity of the server (GB) Actual rate 1DPC 3200 3200 3200 3200 (MT/s) 2DPC 3200 3200 3200 3200 ⚫ a: The maximum number of DDR4 memory modules is based on four-processor configuration.
  • Page 34: Memory Installation Positions

    FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description 5.4.1.5 Memory Installation Positions A server supports a maximum of 48 DDR4 memory modules. To maximize performance, balance the total memory capacity between the installed processors and to load the channels similarly whenever possible.
  • Page 35 FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description Figure 5-21 Memory slots 2022-08-12...
  • Page 36: Memory Protection Technologies

    FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description Figure 5-22 DDR4 memory installation guidelines (2 processors) Figure 5-23 DDR4 memory installation guidelines (4 processors) 5.4.1.6 Memory Protection Technologies The following memory protection technologies are supported: ⚫ ⚫ Memory Mirroring ⚫...
  • Page 37: Memory Protection Technologies

    FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description ⚫ Post Package Repair (PPR) ⚫ Write Data CRC Protection ⚫ Adaptive Data Correction - Single Region (ADC-SR) ⚫ Adaptive Double Device Data Correction - Multiple Region (ADDDC-MR) ⚫ Partial Cache Line Sparing (PCLS) 5.4.1.7 Memory Protection Technologies...
  • Page 38: Pmem

    FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description 5.4.2 PMem 5.4.2.1 Memory Identifier Figure 5-24 Memory identifier Description Example Component Intel Optane Persistent Memory 8089-A2-2008-00002461 Model NMB1XXD512GPSU4 Capacity (GB) ⚫ ⚫ ⚫ SN QR code 8089-A2-2008-00002461 5.4.2.2 Memory Subsystem Architecture The server provides 48 memory slots.
  • Page 39 FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description Memory Channel Memory Slot CPU 1 A (primary) DIMM000(A) DIMM001(G) B (primary) DIMM010(B) DIMM011(H) C (primary) DIMM020(C) DIMM021(I) D (primary) DIMM030(D) DIMM031(J) E (primary) DIMM040(E) DIMM041(K) F (primary) DIMM050(F) DIMM051(L)
  • Page 40: Memory Compatibility

    FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description Memory Channel Memory Slot DIMM231(J) E (primary) DIMM240(E) DIMM241(K) F (primary) DIMM250(F) DIMM251(L) CPU 4 A (primary) DIMM300(A) DIMM301(G) B (primary) DIMM310(B) DIMM311(H) C (primary) DIMM320(C) DIMM321(I) D (primary) DIMM330(D)
  • Page 41: Memory Installation Guidelines

    FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description Total memory capacity = Total capacity of all PMem modules+ Total capacity of all DDR4 memory modules The total memory capacity cannot exceed the maximum memory capacity supported by the CPUs.
  • Page 42: Memory Installation Positions

    FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description Table 5-10 Maximum memory capacity supported by a CPU CPU type Maximum Memory Capacity Supported by a CPU (DDR4 and PMem Capacities) Cooper Lake H series 1.12 TB (6 x 64 GB DDR4 + 6 x 128 GB...
  • Page 43 FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description Figure 5-25 Memory slots 2022-08-12...
  • Page 44 FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description Figure 5-26 PMem installation guidelines (2 processors) 2022-08-12...
  • Page 45: Memory Protection Technologies

    FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description Figure 5-27 PMem installation guidelines (4 processor) 5.4.2.6 Memory Protection Technologies The following memory protection technologies are supported: ⚫ PMem module Error Detection and Correction ⚫ PMem module Device Failure Recovery (SDDC) ⚫...
  • Page 46: Storage

    FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description ⚫ PMem module Viral ⚫ PMem module Address Range Scrub (ARS) ⚫ PMem module Error Injection ⚫ DDR-T Command and Address Parity Check and Retry ⚫ DDR-T Read Write Data ECC Check and Retry ⚫...
  • Page 47 FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description Configuration Front Drive Rear Drive Built-in Drive Drive Management Mode − Intel VROC (SATA RAID) Manages the M.2 SSDs on the M.2 adapter card in slot 10. − 1 x PCIe...
  • Page 48 FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description Configuration Front Drive Rear Drive Built-in Drive Drive Management Mode − Manages NVMe drives in slots 4 to ⚫ M.2 SSD: − 1 x PCIe RAID controlle r card. Manages the M.2...
  • Page 49 FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description Configuration Front Drive Rear Drive Built-in Drive Drive Management Mode NVMe drives in slots 4 to 11 and slots 16 to 23. ⚫ M.2 SSD: − 1 x PCIe RAID controlle r card.
  • Page 50 FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description Configuration Front Drive Rear Drive Built-in Drive Drive Management Mode − The PCIe RAID controlle r card in slot 5 manages drives in slots 16 to 23. ⚫ M.2 SSD: −...
  • Page 51 FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description Configuration Front Drive Rear Drive Built-in Drive Drive Management Mode r card in slot 1. ⚫ ⚫ ⚫ ⚫ 25 x 2.5" drive Front drive: 2 x M.2 2 x M.2 SAS/SATA 25 x 2.5"...
  • Page 52: Drive Numbering

    The drive numbers identified by the RAID controller card vary depending on the cabling of the RAID controller card. The drive numbers identified by the RAID controller card in this section are provided based on the default cabling described in "Internal Cabling" in FusionServer 2488H V6 Server Maintenance and Service Guide. ⚫...
  • Page 53 FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description Drive No. Drive Number Identified Drive Number Identified by the iBMC by the RAID Controller ⚫ 12 x 2.5" drive pass-through configuration (4 x SAS/SATA + 8 x NVMe) Figure 5-29 Slot numbers Table 5-13 Slot numbers Drive No.
  • Page 54 FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description Figure 5-30 Slot numbers Table 5-14 Slot numbers Drive No. Drive Number Identified Drive Number Identified by the iBMC by the RAID Controller ⚫ 24 x 2.5" drive pass-through configuration (24 x SAS/SATA)
  • Page 55 FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description Figure 5-31 Slot numbers Table 5-15 Slot numbers Drive No. Drive Number Identified Drive Number Identified by the iBMC by the RAID Controller 2022-08-12...
  • Page 56 FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description ⚫ 25 x 2.5" drive EXP configuration (25 x SAS/SATA) Figure 5-32 Slot numbers Table 5-16 Slot numbers Drive No. Drive Number Identified Drive Number Identified by the iBMC by the RAID Controller...
  • Page 57: Drive Indicators

    FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description Drive No. Drive Number Identified Drive Number Identified by the iBMC by the RAID Controller 5.5.3 Drive Indicators SAS/SATA Drive Indicators Figure 5-33 SAS/SATA drive indicators Table 5-17 SAS/SATA drive indicators...
  • Page 58 FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description NVMe Drive Indicators Figure 5-34 NVMe drive indicators ⚫ If the VMD function is enabled and the latest VMD driver is installed, the NVMe drives support surprise hot swap. Table 5-18 NVMe drive indicators (VMD enabled)
  • Page 59: Raid Controller Card

    FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description Activity Indicator Fault Indicator Description (Green) (Yellow) Blinking at 0.5 Hz The NVMe drive has completed the hot swap process and is removable. Steady on/Off Steady on The NVMe drive is faulty.
  • Page 60: Network

    FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description ⚫ Contact your local sales representative or see "Search Parts" in the Compatibility Checker to determine the components to be used. ⚫ For details about the RAID controller card, see V6 Server RAID Controller Card User Guide.
  • Page 61: Pcie Slots

    FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description 5.7.2 PCIe Slots PCIe Slots Figure 5-36 PCIe slots ⚫ PCIe riser module 1 provides slots 1, 2, and 3. If a dual-slot PCIe riser module is used, slot 3 is unavailable.
  • Page 62 FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description Figure 5-37 PCIe riser module (universal 3-slot) ⚫ PCIe riser module (universal 2-slot) − Provides PCIe slots 1 and 2 when installed in PCIe riser module 1. − Provides PCIe slots 7 and 8 when installed in PCIe riser module 2.
  • Page 63 FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description Figure 5-39 PCIe riser module (universal 3-slot, supporting GPUs) ⚫ PCIe riser module (universal 2-slot, supporting GPUs) − Provides PCIe slots 1 and 2 when installed in PCIe riser module 1.
  • Page 64: Pcie Slot Description

    FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description 5.7.3 PCIe Slot Description The PCIe slots mapping to a vacant CPU socket are unavailable. Table 5-21 PCIe slot description PCIe PCIe Conne Port Root Device Slot Slot Standa ctor...
  • Page 65: Psus

    FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description PCIe PCIe Conne Port Root Device Slot Standa ctor Port (B/D/F Slot Width Size (B/D/F Width ⚫ 3-sl Slot 10 CPU 2 PCIe Port1C 0x43/2/ 0x45/0/ HHHL ⚫ The B/D/F (Bus/Device/Function Number) is the default value when the server is fully configured with PCIe cards.
  • Page 66: Fan Modules

    FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description Figure 5-41 Positions of PSUs ⚫ When one or two 900 W AC Titanium PSUs are configured and the input voltage ranges from 100 V AC to 127 V AC, the output power decreases to 550 W.
  • Page 67: Lcd

    FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description Figure 5-42 Positions of fan modules 5.10 LCD Only the 8 x 2.5" drive pass-through configuration (8 x SAS/SATA) supports the LCD. Function The LCD displays the installation status and running status of server components and enables users to set the IP address of the iBMC management network port on the server.
  • Page 68 FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description Figure 5-43 LCD subsystem working principle Figure 5-44 LCD main interface Table 5-22 Parameters on the LCD home screen Function Status Displays the port 80 status, serial number, component status, and component alarms of the server.
  • Page 69 FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description Function temperature of the server. Info. Displays the IP address and MAC address of the iBMC management network port, device SNs, asset information, and firmware version. Setting Sets the IP address of the iBMC management network port.
  • Page 70: Boards

    FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description 5.11 Boards 5.11.1 Mainboard Figure 5-45 2488H V6 mainboard Rear USB 3.0 port VGA port (VGA CONN/J14) (USB3.0x2/J80) Serial port (IO/IO/J148) BMC management network port (BMC Mesg/J149) PCIe slot 6 (PCIE...
  • Page 71 FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description PCIe slot 4 (PCIE VROC key connector (SOFT SLOT(CPU1) X8/J130) RAID KEY/J1) NC-SI connector (NCSI PCIe riser 1 slot (PCIE CONN/J129) RISER1(CPU1)/J87) OCP 3.0 network adapter Mini-SAS HD connector connector (OCP CONN/J138)
  • Page 72: Drive Backplane

    FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description backplane (PDB MIS backplane (PDB POWER CONN/J10) CONN/J153/J154/J155) SATA connector 2/DVD SATA connector 1 drive connector (SATA1/J73) (SATA2/DVD/J74) Intrusion sensor connector PCIe riser 2 slot (PCIE (S1) RISER2(CPU2)/J88) a: Reserved and unavailable currently.
  • Page 73 FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description ⚫ 12 x 2.5" drive pass-through backplane (4 x SAS/SATA + 8 x NVMe) Figure 5-47 12 x 2.5" drive pass-through backplane (4 x SAS/SATA + 8 x NVMe) LP slimline 2 connector...
  • Page 74 FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description LP slimline 4 connector LP slimline 2D connector (Slimline4/J1401) (Slimline_2D/J2201) LP slimline 3 connector LP slimline 2C connector (Slimline3/J1301) (Slimline_2C/J2101) Mini-SAS HD Port A LP slimline 2B connector connector (PORTA/J1001)
  • Page 75: Psu Backplane

    FusionServer 2488H V6 Server Technical White Paper 5 Hardware Description Figure 5-50 25 x 2.5" drive EXP backplane (25 x SAS/SATA) Signal connector for the rear Mini-SAS HD Port A backplane (REAR BP0/J32) connector (PORTA/J28) Mini-SAS HD Port B Mini-SAS HD Rear Port...
  • Page 76: Product Specifications

    FusionServer 2488H V6 Server Technical White Paper 6 Product Specifications Product Specifications 6.1 Technical Specifications 6.2 Environmental Specifications 6.3 Physical Specifications 6.1 Technical Specifications Table 6-1 Technical specifications Component Specifications Form factor 2U rack server ® Chipset Intel C621A Processor Supports two or four processors.
  • Page 77 FusionServer 2488H V6 Server Technical White Paper 6 Product Specifications Component Specifications − Max. 3200 MT/s memory speed − RDIMM and LRDIMM support − The DDR4 memory modules of different types (RDIMM and LRDIMM) and specifications (capacity, bit width, rank, and height) cannot be used together.
  • Page 78 FusionServer 2488H V6 Server Technical White Paper 6 Product Specifications Component Specifications ⚫ Do not use M.2 SSDs for cache. ⚫ Supports hot swap of SAS/SATA/NVMe U.2 drives. NOTE The NVMe drives support: ⚫ Before using the VMD function, contact technical support engineers of the OS vendor to check whether the OS supports the VMD function.
  • Page 79: Environmental Specifications

    FusionServer 2488H V6 Server Technical White Paper 6 Product Specifications Component Specifications ⚫ Ports on the rear panel: − Two USB 3.0 ports − One DB15 VGA port − One RJ45 serial port − One RJ45 management network port ⚫...
  • Page 80 FusionServer 2488H V6 Server Technical White Paper 6 Product Specifications Category Specifications (–22° F to 140° F) Storage temperature (within six months): –15° C to +45° C ⚫ (5° F to 113° F) Storage temperature (within one year): –10° C to +35° C ⚫...
  • Page 81: Physical Specifications

    FusionServer 2488H V6 Server Technical White Paper 6 Product Specifications Category Specifications declared average bystander position A-weighted sound pressure levels (LpAm) listed are measured at 23° C (73.4° F) in accordance with ISO 7779 (ECMA 74) and declared in accordance with ISO 9296 (ECMA 109).
  • Page 82 FusionServer 2488H V6 Server Technical White Paper 6 Product Specifications Item Description NOTE See Figure 6-1 for methods in measuring physical dimensions of the chassis. Installation dimension ⚫ Requirements for cabinet installation: requirements Cabinet compliant with the International Electrotechnical Commission (IEC) 297 standard −...
  • Page 83 FusionServer 2488H V6 Server Technical White Paper 6 Product Specifications Item Description Energy consumption The power consumption parameters vary with hardware configurations (including the configurations complying with EU ErP). Use the Power Calculator to obtain specific information. 2022-08-12...
  • Page 84: Software And Hardware Compatibility

    FusionServer 2488H V6 Server Technical White Paper 7 Software and Hardware Compatibility Software and Hardware Compatibility Use the Compatibility Checker to obtain information about the operating systems and hardware supported. ⚫ If incompatible components are used, the device may be abnormal. This fault is beyond the scope of technical support and warranty.
  • Page 85: Safety Instructions

    FusionServer 2488H V6 Server Technical White Paper 8 Safety Instructions Safety Instructions 8.1 Security 8.2 Maintenance and Warranty 8.1 Security General Statement ⚫ Comply with local laws and regulations when installing devices. These Safety Instructions are only a supplement. ⚫...
  • Page 86 FusionServer 2488H V6 Server Technical White Paper 8 Safety Instructions Figure 8-1 Safety work wear ⚫ Before touching a device, wear ESD clothing and gloves (or wrist strap), and remove any conductive objects (such as watches and jewelry). Figure 8-2 shows conductive objects that must be removed before you touch a device.
  • Page 87 FusionServer 2488H V6 Server Technical White Paper 8 Safety Instructions Figure 8-3 Wearing an ESD wrist strap ⚫ Exercise caution when using tools. ⚫ If the installation position of a device is higher than the shoulders of the installation personnel, use a vehicle such as a lift to facilitate installation. Prevent the device from falling down and causing personal injury or damage to the device.
  • Page 88: Maintenance And Warranty

    FusionServer 2488H V6 Server Technical White Paper 8 Safety Instructions ⚫ Transport each device in its original packaging. ⚫ If the original packaging is unavailable, package heavy, bulky parts (such as chassis and blades) and fragile parts (such as PCIe cards and optical modules) separately.
  • Page 89: System Management

    FusionServer 2488H V6 Server Technical White Paper 9 System Management System Management This product integrates the new-generation Intelligent Baseboard Management Controller (iBMC), which complies with Intelligent Platform Management Interface 2.0 (IPMI 2.0) specifications and provides reliable hardware monitoring and management.
  • Page 90 FusionServer 2488H V6 Server Technical White Paper 9 System Management ⚫ System maintenance interface − The virtual KVM and virtual media functions facilitate remote maintenance. − The iBMC supports out-of-band RAID monitoring and configuration to improve RAID configuration efficiency and management capabilities.
  • Page 91: Certifications

    FusionServer 2488H V6 Server Technical White Paper 10 Certifications Certifications Country/Region Certification Standards Europe WEEE 2012/19/EU Europe REACH EC NO. 1907/2006 Europe Safety: EN 62368-1:2014+A11:2017 EMC: EN 55032:2015+A11:2020 CISPR 32:2015+A1:2019 EN IEC 61000-3-2:2019+A1:2021 EN 61000-3-3:2013+A1:2019 EN 55035:2017+A11:2020 CISPR 35:2016 EN 55024:2010+A1:2015 CISPR 24:2010+A1:2015 ETSI EN 300 386 V1.6.1:2012...
  • Page 92 FusionServer 2488H V6 Server Technical White Paper 10 Certifications Country/Region Certification Standards CISPR 35:2016 EN 55024:2010+A1:2015 CISPR 24:2010+A1:2015 ETSI EN 300 386 V1.6.1:2012 ETSI EN 300 386 V2.1.1:2016 RoHS: BS EN IEC 63000:2018 ErP: Commission Regulation(EU) 424/2019 FCC PART 15...
  • Page 93: A Appendix

    FusionServer 2488H V6 Server Technical White Paper A Appendix Appendix A.1 Chassis Label The label information and location are for reference only. For details, see the actual product. A.1.1 On the Front Top Figure A-1 Chassis head label Nameplate Certificate...
  • Page 94 FusionServer 2488H V6 Server Technical White Paper A Appendix device. A.1.1.1 Nameplate Figure A-2 Nameplate example Table A-1 Nameplate description Description Server Model For details, see A.4 Nameplate. Device names Power Supply Requirements Vendor Information Authentication ID A.1.1.2 Certificate Figure A-3 Sample certificate of conformity...
  • Page 95 FusionServer 2488H V6 Server Technical White Paper A Appendix Table A-2 Certificate of conformity description Description Order NOTE For details, see Figure A-4 and Table A-3. QC inspector Production date No. Barcode Figure A-4 Sample certificate number Table A-3 Certificate No. Description Description "P", fixed...
  • Page 96 FusionServer 2488H V6 Server Technical White Paper A Appendix Description ⚫ Letters A to H indicate 10 to 17:00. ⚫ Letters J to N indicate 18 to 22:00. ⚫ Letters P to Q indicate 23 to 24:00. Serial number (2 digits) Manufacturing serial number (5 digits).
  • Page 97 FusionServer 2488H V6 Server Technical White Paper A Appendix A.1.2 Chassis Tail Label Figure A-6 Chassis tail label For details about the warning label, see Server Security Information. A.1.3 Chassis Internal Label Figure A-7 Chassis internal label ⚫ The quick guide is located on the inside of the chassis cover. It describes how to remove the mainboard components, important components of the chassis, precautions, and QR codes of technical resources.
  • Page 98 FusionServer 2488H V6 Server Technical White Paper A Appendix Figure A-8 SN example Table A-5 SN description Description ESN ID (two characters), which can only be 21. Material ID (eight characters), that is, the processing code. Vendor code (two characters), that is, the code of the processing place.
  • Page 99 FusionServer 2488H V6 Server Technical White Paper A Appendix Configuration Maximum Maximum Maximum Maximum Operating Operating Operating Operating Temperature Temperature Temperature Temperature 30° C (86° F) 35° C (95° F) 40° C (104° F) 45° C (113° F) configuration (8...
  • Page 100 FusionServer 2488H V6 Server Technical White Paper A Appendix Configuration Maximum Maximum Maximum Maximum Operating Operating Operating Operating Temperature Temperature Temperature Temperature 30° C (86° F) 35° C (95° F) 40° C (104° F) 45° C (113° F) supported. ⚫...
  • Page 101 FusionServer 2488H V6 Server Technical White Paper A Appendix Configuration Maximum Maximum Maximum Maximum Operating Operating Operating Operating Temperature Temperature Temperature Temperature 30° C (86° F) 35° C (95° F) 40° C (104° F) 45° C (113° F) ⚫ GPU cards are not supported.
  • Page 102 A.5 RAS Features The server supports a variety of Reliability, Availability, and Serviceability (RAS) features. You can configure these features for better performance. For details about the RAS features, see FusionServer 2488H V6 Server RAS Technical White Paper. A.6 Sensor List...
  • Page 103 FusionServer 2488H V6 Server Technical White Paper A Appendix Sensor Description Component CPU 2: component in position U134 on the mainboard CPU 3: component in position U52 on the mainboard CPU 4: component in position U53 on the mainboard N indicates the CPU number.
  • Page 104 FusionServer 2488H V6 Server Technical White Paper A Appendix Sensor Description Component Power Button Power button pressed Left mounting ear UID Button UID button status Left mounting ear AreaIntrusion Chassis cover status Chassis cover DISKN Disk status Drive. N indicates the physical drive slot number.
  • Page 105 FusionServer 2488H V6 Server Technical White Paper A Appendix Sensor Description Component voltage detection for soft-start (CPU 3)) SYS 12V_4 Mainboard 12.0 V voltage (the fourth output 12 V voltage detection for soft-start (CPU 4)) SYS 12V_5 Mainboard 12.0 V voltage...
  • Page 106 FusionServer 2488H V6 Server Technical White Paper A Appendix Sensor Description Component Mngmnt Health Management subsystem health status RiserN Card Hardware presence SAS Cable Hardware presence PCIe RAIDN Temp Temperature of the RAID controller card OCPN Temp OCP NIC temperature...
  • Page 107 FusionServer 2488H V6 Server Technical White Paper A Appendix Sensor Description Component Memory Usage Memory usage PCIeN Card BBU BBU fault or low voltage on a PCIe card BMC Time Hopping Time hopping NTP Sync Failed NTP synchronization failure and recovery events...
  • Page 108: B Glossary

    FusionServer 2488H V6 Server Technical White Paper B Glossary Glossary B.1 A-E The baseboard management controller (BMC) complies with the Intelligent Platform Management Interface (IPMI). It collects, processes, and stores sensor signals, and monitors the operating status of components. The BMC provides the...
  • Page 109 FusionServer 2488H V6 Server Technical White Paper B Glossary hot swap Replacing or adding components without stopping or shutting down the system. B.3 K-O A hardware device that provides public video, keyboard and mouse (KVM). B.4 P-T panel An external component (including but not limited to ejector levers, indicators, and ports) on the front or rear of the server.
  • Page 110 FusionServer 2488H V6 Server Technical White Paper B Glossary system event log Event records stored in the system used for subsequent fault (SEL) diagnosis and system recovery. B.5 U-Z A unit defined in International Electrotechnical Commission (IEC) 60297-1 to measure the height of a cabinet, chassis, or subrack.
  • Page 111: C Acronyms And Abbreviations

    FusionServer 2488H V6 Server Technical White Paper C Acronyms and Abbreviations Acronyms and Abbreviations C.1 A-E alternating current Advanced Encryption Standard New Instruction Set Address Resolution Protocol Advanced Vector Extensions backup battery unit BIOS Basic Input/Output System baseboard management controller...
  • Page 112 FusionServer 2488H V6 Server Technical White Paper C Acronyms and Abbreviations direct current DDR4 Double Data Rate 4 DDDC double device data correction DEMT Dynamic Energy Management Technology DIMM dual in-line memory module DRAM dynamic random-access memory digital video disc...
  • Page 113 FusionServer 2488H V6 Server Technical White Paper C Acronyms and Abbreviations high availability hard disk drive high-performance computing HTTP Hypertext Transfer Protocol HTTPS Hypertext Transfer Protocol Secure iBMC intelligent baseboard management controller Industry Canada ICMP Internet Control Message Protocol Internet Data Center...
  • Page 114 FusionServer 2488H V6 Server Technical White Paper C Acronyms and Abbreviations LRDIMM load-reduced dual in-line memory module light emitting diode LAN on motherboard media access control module management controller next business day NC-SI Network Controller Sideband Interface Open Compute Project C.4 P-T...
  • Page 115 FusionServer 2488H V6 Server Technical White Paper C Acronyms and Abbreviations reliability, availability and serviceability RDIMM registered dual in-line memory module REACH Registration Evaluation and Authorization of Chemicals RJ45 registered jack 45 RoHS Restriction of the Use of Certain Hazardous Substances in...
  • Page 116 FusionServer 2488H V6 Server Technical White Paper C Acronyms and Abbreviations Trusted Execution Technology TransFlash module TFTP Trivial File Transfer Protocol TCP offload engine trusted platform module C.5 U-Z UDIMM unbuffered dual in-line memory module UEFI Unified Extensible Firmware Interface unit identification light Underwriter Laboratories Inc.

Table of Contents