xFusion Digital Technologies FusionServer 5288 V7 Manual page 87

Table of Contents

Advertisement

FusionServer 5288 V7 Server
Technical White Paper
NVMe Drive Indicator
Figure 5-41 NVMe drive indicator
Issue 01 (2023-07-20)
If the VMD function is enabled and the latest VMD driver is installed, the NVMe
drives support surprise hot swap.
Table 5-16 NVMe drive indicator description (VMD function enabled)
Activity
Indicator
(Green)
Off
Steady on
Blinking at 4 Hz
Steady on/
blinking
Blinking at 1 Hz
Steady on/Off
If the VMD function is disabled, the NVMe drives support only orderly hot swap.
Table 5-17 NVMe drive indicator description (VMD function disabled)
Activity
Indicator
(Green)
Off
Steady on
Copyright © xFusion Digital Technologies Co., Ltd.
Fault Indicator
Description
(Red/Blue)
Off
The NVMe drive is not detected.
Off
The NVMe drive is detected and
operating properly.
Off
Data is being read from or written to
the NVMe drive.
Blinking blue at 4
The NVMe drive is being located.
Hz
Blinking red at 1
Data on the NVMe secondary drive is
Hz synchronously
being rebuilt.
Red steady on
The NVMe drive is faulty.
Fault Indicator
Description
(Red/Blue)
Off
The NVMe drive is not detected.
Off
The NVMe drive is detected and
operating properly.
5 Hardware Description
80

Advertisement

Table of Contents
loading

Table of Contents