FusionServer 1288H V7 Server
Technical White Paper
Issue
02
Date
2023-05-25
xFusion Digital Technologies Co., Ltd.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FusionServer 1288H V7 and is the answer not in the manual?

Questions and answers

Summary of Contents for xFusion Digital Technologies FusionServer 1288H V7

  • Page 1 FusionServer 1288H V7 Server Technical White Paper Issue Date 2023-05-25 xFusion Digital Technologies Co., Ltd.
  • Page 2 Notice In this document, "xFusion" is used to refer to "xFusion Digital Technologies Co., Ltd." for concise description and easy understanding, which does not mean that "xFusion" may have any other meaning. Any "xFusion" mentioned or described hereof may not be understood as any meaning other than "xFusion Digital Technologies Co., Ltd.", and xFusion Digital Technologies Co., Ltd.
  • Page 3: About This Document

    About This Document Purpose This document describes the appearance, features, performance parameters, and hardware and software compatibility of FusionServer 1288H V7, so that users can have an in-depth and detailed understanding of FusionServer 1288H V7. Intended Audience This document is intended for pre-sales engineers.
  • Page 4 FusionServer 1288H V7 Server Technical White Paper About This Document Change History Issue Release Date Change Description 2023-06-21 This issue is the first official release. Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 5: Table Of Contents

    5.5.1.2 8 x 2.5" Drive Pass-Through Configuration..................31 5.5.1.3 10 x 2.5" Drive Pass-Through Configuration..................33 5.5.1.4 10 x 2.5" Drive NVMe Configuration....................37 5.5.2 Drive Indicators............................38 5.5.3 RAID Controller Card..........................40 Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 6 A.2 Product SN..............................76 A.3 Operating Temperature Limitations......................78 A.4 Nameplate..............................83 A.5 RAS Features............................83 A.6 Sensor List..............................83 B Glossary......................... 90 B.1 A-E................................90 B.2 F-J................................91 B.3 K-O................................91 B.4 P-T................................91 Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 7 FusionServer 1288H V7 Server Technical White Paper Contents B.5 U-Z................................92 C Acronyms and Abbreviations..................93 C.1 A-E................................93 C.2 F-J................................94 C.3 K-O................................95 C.4 P-T................................96 C.5 U-Z................................98 Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 8: Overview

    Technical White Paper 1 Overview Overview FusionServer 1288H V7 (1288H V7) is a new-generation 1U 2-socket rack server designed for the Internet, Internet Data Center (IDC), cloud computing, enterprise business, and telecom. The 1288H V7 server is ideal for IT core services, cloud computing, virtualization, high-performance computing, distributed storage, big data processing, enterprise or telecom applications, and other complex workloads.
  • Page 9: Product Features

    RAID 0, 1, 1E, 10, 5, 50, 6, and 60, depending on the RAID controller card used. It also uses a supercapacitor to protect the RAID cache data against power failures. Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 10 ● Supports secure boot based on the chip-level Root of Trust (RoT) and provides the level-by-level verification function starting from the hardware trusted root, building a complete secure boot chain. Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 11 The improved thermal design with energy-efficient fans ensures optimal heat dissipation and reduces system power consumption. ● The server is protected with power capping and power control measures. ● Staggered spinup of drives reduces the server boot power consumption. Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 12: Physical Structure

    Figure 3-1 Physical structure of a server with 8 x 2.5" drives (example) I/O module 1 I/O module 2 Chassis Air duct Intrusion sensor Front-drive backplane Front drives Indicator board module Fan modules Fan module bracket Cable management arm Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 13 FusionServer 1288H V7 Server Technical White Paper 3 Physical Structure Fan board Processor heat sinks Processors Mainboard Memory modules TPM/TCM OCP 3.0 NICs BMC card Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 14: Logic Structure

    PCBs or cables. Different PCIe riser cards support PCIe slots of different specifications. CPU 1 and CPU 2 each support one OCP 3.0 NIC. The PCIe slot bandwidth is scalable to x16. Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 15 4 Logic Structure ● The BMC management chip integrated on the mainboard supports ports such as a video graphic array (VGA) port, a management network port, and a serial port. Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 16: Hardware Description

    5.8 PSUs 5.9 Fan Module 5.10 Board 5.1 Front Panel 5.1.1 Appearance ● 4 x 3.5" drive configuration Figure 5-1 Front view Drive Slide-out label plate (with an SN label) Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 17: Indicators And Buttons

    4 x 3.5" drive configuration Figure 5-4 Indicators and buttons on the front panel Fault diagnosis LED Health status indicator FlexIO card 1 presence FlexIO card 2 presence indicator indicator Power button/indicator UID button/indicator Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 18 Figure 5-6 Indicators and buttons on the front panel Fault diagnosis LED Health status indicator FlexIO card 1 presence FlexIO card 2 presence indicator indicator UID button/indicator iBMC direct connect management port indicator Power button/indicator Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 19 ● Blinking green at 2 Hz: The FlexIO card is detected and has just been inserted. ● Steady green: The FlexIO card is detected and the power supply is normal. Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 20 ● You can press this button to turn on or off the UID indicator. ● You can press and hold down this button for 4 to 6 seconds to reset the iBMC. Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 21: Ports

    4 x 3.5" drive configuration Figure 5-7 Ports on the front panel iBMC direct connect USB 3.0 port management port USB 3.0 port VGA port ● 8 x 2.5" drive configuration Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 22 Port Description Table 5-2 Ports on the front panel Name Type Description Note Quantity VGA port DB15 Used to connect a display terminal, such as a monitor or KVM. Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 23: Rear Panel

    CD/DVD drives, an external power supply is required. Note: The number of ports varies depending on server configuration. This table lists the maximum number of ports in different configurations. 5.2 Rear Panel Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 24: Appearance

    5.2.2 Indicators and Buttons Indicator Positions Figure 5-11 Indicators on the rear panel Data transmission status Connection status indicator indicator of the of the management management network port network port Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 25 The possible causes of no output are as follows: ● Power supply overtemperature protection ● Power output overcurrent or short- circuit ● Output overvoltage ● Short-circuit protection ● Device failure (excluding failure of all devices) Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 26: Ports

    NOTE The management network port is a GE port that supports 100 Mbit/s and 1000 Mbit/s auto-negotiation. Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 27: Processors

    The server supports one or two processors. ● If only one processor is required, install it in socket CPU 1. ● Processors of the same model must be used in a server. Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 28: Memory

    Figure 5-13 Positions of the processors 5.4 Memory 5.4.1 DDR5 Memory 5.4.1.1 Memory Identifier You can determine the memory module properties based on the label attached to the memory module. Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 29 ● B = 40-40-40 ● C = 42-42-42 DIMM type ● Reference design for version RDIMM D0 SPD Version ● 10: SPD version ● 10: SPD versions from Byte 192 to Byte 447 Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 30: Memory Subsystem Architecture

    DIMM011(J) C (primary) DIMM020(C) DIMM021(K) D (primary) DIMM030(D) DIMM031(L) E (primary) DIMM040(E) DIMM041(M) F (primary) DIMM050(F) DIMM051(N) G (primary) DIMM060(G) DIMM061(O) H (primary) DIMM070(H) DIMM071(P) CPU 2 A (primary) DIMM100(A) Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 31: Memory Compatibility

    ● The calculation formula of total memory capacity supported is as follows: the total memory capacity equals the capacity sum of all DDR5 memory modules. Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 32: Dimm Installation Rules

    ● The memory modules configured must be DDR5 RDIMMs. ● The memory modules must be configured with the same number of ranks. ● Install filler memory modules in vacant slots. Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 33: Positions Of The Memory Modules

    The server supports up to 32 DDR5 memory modules. Observe the memory module installation rules when configuring memory modules. For details, see the Server Assembly Guide. Figure 5-15 Positions of the memory modules Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 34 FusionServer 1288H V7 Server Technical White Paper 5 Hardware Description Figure 5-16 DDR5 memory module installation guidelines (1 processor) Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 35 FusionServer 1288H V7 Server Technical White Paper 5 Hardware Description Figure 5-17 DDR5 memory module installation guidelines (2 processors) Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 36: Memory Protection Technologies

    ● 1 x PCIe RAID pass-through x 3.5"): controller card configuration 2 The PCIe RAID – Slots 0 to 3 controller card support only is installed in SAS/SATA slot 1 by drives. default. Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 37 RAID controller card. This section uses the drive numbers identified by a RAID controller card that adopts the default cabling described in "Internal Cabling" in the FusionServer 1288H V7 Server Maintenance and Service Guide. ● Drive numbers of the 4 x 3.5" drive pass-through configuration 1 in Table 5-7.
  • Page 38: X 2.5" Drive Pass-Through Configuration

    RAID controller card. This section uses the drive numbers identified by a RAID controller card that adopts the default cabling described in "Internal Cabling" in the FusionServer 1288H V7 Server Maintenance and Service Guide. Issue 02 (2023-05-25)
  • Page 39 Drive numbers of the 8 x 2.5" drive pass-through configuration 2 in Table 5-10. Figure 5-21 Drive numbering Table 5-12 Drive numbering Drive Number Drive Number Drive Number Displayed on the iBMC Identified by the RAID WebUI Controller Card Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 40: 10 X 2.5" Drive Pass-Through Configuration

    – Slots 6 and slot 1 by 7 support default. SAS/SATA/ ● NVMe drive: NVMe CPU pass- drives. through – Slots 8 and 9 support only NVMe drives. Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 41 RAID controller card. This section uses the drive numbers identified by a RAID controller card that adopts the default cabling described in "Internal Cabling" in the FusionServer 1288H V7 Server Maintenance and Service Guide. ● Drive numbers of the 10 x 2.5" drive pass-through configuration 1 in Table 5-13.
  • Page 42 Drive numbers of the 10 x 2.5" drive pass-through configuration 2 in Table 5-13. Figure 5-23 Drive numbering Table 5-15 Drive numbering Drive Number Drive Number Drive Number Displayed on the iBMC Identified by the RAID WebUI Controller Card Note Note Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 43 Drive numbers of the 10 x 2.5" drive pass-through configuration 3 in Table 5-13. Figure 5-24 Drive numbering Table 5-16 Drive numbering Drive Number Drive Number Drive Number Displayed on the iBMC Identified by the RAID WebUI Controller Card Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 44: 10 X 2.5" Drive Nvme Configuration

    RAID controller card. This section uses the drive numbers identified by a RAID controller card that adopts the default cabling described in "Internal Cabling" in the FusionServer 1288H V7 Server Maintenance and Service Guide. ● Drive numbers of the 10 x 2.5" drive NVMe configuration in Table 5-17.
  • Page 45: Drive Indicators

    5.5.2 Drive Indicators SAS/SATA Drive Indicators Figure 5-26 SAS/SATA drive indicators Table 5-19 SAS/SATA drive indicator description Activity Indicator Fault Indicator Description (Green) (Red/Blue) The drive is not detected. Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 46 The NVMe drive is not detected. Steady on The NVMe drive is detected and operating properly. Blinking at 4 Hz Data is being read from or written to the NVMe drive. Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 47: Raid Controller Card

    For details about the optional components, consult the local sales representative or see "OS and Parts Compatibility" in the Compatibility Checker. ● For details about the RAID controller card, see the V7 Server RAID Controller Card User Guide. 5.6 Network Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 48: Ocp 3.0 Nics

    I/O module 1 provides slots 1 and 2. ● I/O module 2 provides slot 3. PCIe Riser Card ● PCIe riser card of I/O module 1 Provides PCIe slots 1 and 2 in I/O module 1. Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 49: Pcie Slot Description

    ● The PCIe port numbers in table 1 correspond to CPUs. For details about the PCIe port number displayed on the BIOS screen, see the Server Eagle Stream Platform BIOS Parameter Reference. Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 50 PCIe card. ● The FHHL PCIe slots are compatible with FHHL PCIe cards and HHHL PCIe cards. ● The maximum power supply of each PCIe slot is 75 W. Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 51: Psus

    CCC certification. ● For details about the optional components, consult the local sales representative or see "OS and Parts Compatibility" in the Compatibility Checker. Figure 5-31 Positions of PSUs Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 52: Fan Module

    Supports intelligent fan speed adjustment. ● Fan modules of the same part number (P/N code) must be used in a server. Figure 5-32 Positions of the fan modules 5.10 Board Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 53: Mainboard

    OCP 3.0 NIC 2 connector RAID&M.2 mezzanine card (OCP2 CONN/J6073) signal connector (RAID&M. 2/J6063) OCP 3.0 NIC 2 UBC Built-in HDD backplane & connector (UBC2-5/J6071) BBU signal connector (INNER BP&BBU/J6084) Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 54 CPU 2 southbound UBC connector (UBC2-3/J44) connector (UBC2-2/J41) CPU 2 southbound UBC CPU 2 northbound UBC connector (UBC2-1/J40) connector (UBC2-6/J53) Left mounting ear BBU power connector connector (J6081) (BBU PWR/J6079) Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 55: Drive Backplane

    (HDD BP/ J19) Power connector (HDD_POWER/J21) ● 8 x 2.5" drive pass-through backplane This backplane is used for all drive configurations described in section 5.5.1.2 8 x 2.5" Drive Pass-Through Configuration. Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 56 Slots 8 and 9 (PORT C/J8) Mini-SAS HD connector Slots 4 to 7 (PORT B/J7) Mini-SAS HD connector Slots 0 to 3 (PORT A/J6) Backplane signal cable connector (HDD BP/ J20) Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 57 Slots 2 and 3 (UBC12CPU1 /J2) PSU connector (HDD POWER /J21) Indicator signal cable connector (HDD_BP/ J20) UBC connector Slots 0 and 1 (UBC11CPU1 /J1) UBC connector Slots 4 and 5 (UBC13CPU1 /J3) Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 58: Fan Board

    Fan board signal connector Fan connector (FAN8 / (FAN_BOARD/J3) J1401) Fan connector (FAN7 / Fan connector (FAN6 / J1301) J1201) Fan connector (FAN5 / Fan board power J1101) connector (J1) Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 59 FusionServer 1288H V7 Server Technical White Paper 5 Hardware Description Fan connector (FAN4 / Fan connector (FAN3 / J1001) J901) Fan connector (FAN2 / Fan connector (FAN1 / J801) J701) Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 60: Specifications

    ● Min. 1.875 MB L3 cache per core ● Max. 350 W thermal design power (TDP) NOTE The preceding information is for reference only. For details, see "Search Parts" in the Compatibility Checker. Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 61 For details about the RAID controller card, see the Server RAID Controller Card User Guide. NOTE If the BIOS is in legacy mode, the 4K drive cannot be used as the boot drive. Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 62 – One RJ45 serial port – One RJ45 management network port ● Built-in ports: – Two SATA ports NOTE You are not advised to install the OS on the USB storage media. Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 63 Security feature ● Power-on password ● Administrator password ● TPM (for China and outside China)/TCM (only for China) ● Secure boot ● Front bezel (optional) ● Chassis cover opening detection Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 64: Environmental Specifications

    1ºC (1.8°F) for every increase of 125 m (410.10 ft). ● HDDs cannot be used at an altitude of over 3050 m (10,006.56 ft). Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 65 6 months in unpacked/packed and powered-off state ● The maximum preservation duration is determined according to the preservation specifications provided by drive vendors. For details, see the manuals provided by drive vendors. Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 66: Physical Specifications

    ● The measuring method for chassis with 3.5" drives and that for chassis with 2.5" drives are the same. The chassis with 3.5" drives is used as an example. Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 67 ● Packaging materials: 5 kg (11.03 lb) Power consumption The power consumption parameters vary with hardware configurations (including the configurations complying with EU ErP). Use the Power Calculator to obtain specific information. Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 68: Software And Hardware Compatibility

    ● If the customer has requirements on hardware performance consistency, specify the specific configuration requirements (for example, specific drive models, RAID controller cards, or firmware versions) in the presales phase. Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 69: Safety Instructions

    Do not carry the weight that exceeds the maximum load per person allowed by local laws or regulations. Before moving a device, check the maximum device weight and arrange required personnel. Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 70 Fasten the strap buckle and ensure that the ESD wrist strap is in contact with your skin. Insert the ground terminal attached to the ESD wrist strap into the jack on the grounded cabinet or chassis. Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 71 Transportation precautions include but are not limited to: ● The logistics company engaged to transport the device must be reliable and comply with international standards for transporting electronics. Ensure that the Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 72: Maintenance And Warranty

    ● Female: 10/22.05 of the People's Republic of China (AQSIQ) For more information about safety instructions, see Server Safety Information. 8.2 Maintenance and Warranty For details about maintenance, see Customer Support Service. Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 73 FusionServer 1288H V7 Server Technical White Paper 8 Safety Instructions For details on warranty, see Warranty. Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 74: System Management

    NMS platform to collect the fault information about the server. – If the server is configured with the LCD module, the LCD can directly obtain device information from the iBMC. ● Security management methods Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 75 License management allows advanced features to be used by authorized users. The advanced edition of the iBMC provides the following features: – Use Redfish to deploy the OS. – Use Redfish to collect raw data for intelligent diagnosis. Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 76: Certifications

    EN 55032:2015+A1:2020 CISPR 32:2015+A1:2019 EN IEC 61000-3-2:2019+A1:2021 EN 61000-3-2:2013+A2:2021 EN 61000-3-2:2014 EN 61000-3-3:2013 EN 55035:2017+A11:2020 CISPR 35:2016 EN 55024:2010+A1:2015 CISPR 24:2010+A1:2015 RoHS: EN IEC 63000:2018 ErP: Commission Regulation (EU) No 2019/424 Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 77 EN 55035:2017+A11:2020 CISPR 35:2016 EN 55024:2010+A1:2015 CISPR 24:2010+A1:2015 RoHS: BS EN IEC 63000:2018 ErP: Commission Regulation (EU) No 2019/424 China GB4943.1-2011 GB/T 9254.1-2021 GB17625.1-2012 FCC PART 15 Japan VCCI VCCI 32-1 Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 78: A Appendix

    NOTE For details, see A.2 Product Reserved space for customized Pressure-proof label label NOTE This label warns users not to place any objects on top of a rack- mounted device. Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 79: Nameplate

    Figure A-2 Nameplate example Table A-1 Nameplate description Description Server model NOTE For details, see Nameplate. Device name Power supply requirements Vendor information Certification marks A.1.1.2 Certificate Figure A-3 Certificate example Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 80 ● Letters A to H indicate the 10th to 17th. ● Letters J to N indicate the 18th to 22nd. ● Letters P to Y indicate the 23rd to 31st. Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 81: Quick Access Label

    Subnet mask of the iBMC management network port Default iBMC user name Default iBMC password Default BIOS password Technical support website P/N code QR code NOTE Scan the QR code to obtain technical support resources. Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 82: Chassis Internal Label

    ● The quick start guide is optional. For details, see the actual product. A.1.3 Chassis Tail Label Figure A-7 Chassis tail label NO TE For details about the warning label, see the Server Safety Information. Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 83: Product Sn

    – Digits 1 to 9 indicate January to September respectively. – Letters A to C indicate October to December respectively. Serial number (six characters) RoHS compliance status (one character). Y indicates RoHS compliant. Internal model, that is, product name. Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 84 – Letters A to C indicate October to December respectively. Serial number (six characters) RoHS compliance status (one character). Y indicates RoHS compliant. Nameplate (six characters). Serial number. The number of digits depends on the actual product. Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 85: Operating Temperature Limitations

    ● Supercapa supported. citors are supported. ● OCP 3.0 NICs whose rate is greater than 100 Gbit/s are supported. ● PCIe NICs whose rate is greater than 100 Gbit/s are supported. Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 86 100 is greater Gbit/s are than 25 Gbit/s are supported. supported. ● PCIe NICs whose rate ● Supercapa is greater citors are than 100 Gbit/s are supported. supported. Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 87 25 Gbit/s than 100 or higher Gbit/s are are not supported. supported. ● Supercapa ● PCIe NICs citors are whose rate is greater supported. than 100 Gbit/s are supported. Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 88 ● PCIe NICs than 25 whose rate Gbit/s are is greater than 100 supported. Gbit/s are ● Supercapa supported. citors are supported. Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 89 ● Rear drives than 100 are not Gbit/s are supported. supported. ● Supercapa citors are ● PCIe NICs whose rate supported. equals to or is greater than 100 Gbit/s are supported. Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 90: Nameplate

    BMC card BMC management chip SSD Max Temp Maximum SSD temperature (reported by BMA) CPUN Core Temp CPU core temperature CPUN N indicates the CPU number. The value is 1 or Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 91 CPUN Prochot CPU Prochot CPUN N indicates the CPU number. The value is 1 or CPUN VCCIN CPU VCCIN voltage Mainboard N indicates the CPU number. The value is 1 or Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 92 CPU VCCD temperature CPUN N indicates the CPU number. The value is 1 or PSN VIN PSU N input voltage PSU N N indicates the PSU number. The value is 1 or Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 93 The value ranges from 1 to 8. FANN F Presence Fan presence Fan module N N indicates the fan ID. FANN R Presence The value ranges from 1 to 8. Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 94 Riser card SAS Cable Entity presence SAS cable LCD Status LCD health status LCD Presence LCD presence DISK$ Drive status Drive RAID Presence RAID controller card RAID controller card presence Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 95 SSD Disk$ Temp SSD temperature GPU$ Power GPU card power GPU card GPU$ Temp GPU card temperature GPU card System Notice Hot restart reminder and fault diagnosis program information collection Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 96 Operation log full or events being cleared Sec. Log Full Security log full or events being cleared Host Loss System monitoring software (BMA) link loss detection ProductID Status Product identification status Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 97: B Glossary

    DEC. Ethernet uses the Carrier Sense Multiple Access/Collision Detection (CSMA/CD) access method and allows data transfer over various cables at 10 Mbit/s. The Ethernet specification is the basis for the IEEE 802.3 standard. Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 98: F-J

    A PCI system can be transformed to a PCIe system by modifying the physical layer instead of software. PCIe delivers a faster speed and can replace almost all AGP and PCI buses. Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 99: U-Z

    A unit defined in International Electrotechnical Commission (IEC) 60297-1 to measure the height of a cabinet, chassis, or subrack. 1U = 44.45 mm (1.75 in). UltraPath A point-to-point processor interconnect developed by Interconnect (UPI) Intel. Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 100: C Acronyms And Abbreviations

    Advanced Encryption Standard New Instruction Set Address Resolution Protocol Advanced Vector Extensions backup battery unit BIOS Basic Input/Output System baseboard management controller China Compulsory Certification calendar day Conformite Europeenne Common Information Model command-line interface Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 101: F-J

    ID European Efficiency enterprise resource planning European Telecommunication Standards C.2 F-J FB-DIMM Fully Buffered DIMM Fiber Channel Federal Communications Commission FCoE Fibre Channel over Ethernet File Transfer Protocol Gigabit Ethernet Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 102: K-O

    Internet Group Message Protocol IOPS input/output operations per second Internet Protocol Intelligent Power Capability IPMB Intelligent Platform Management Bus IPMI Intelligent Platform Management Interface C.3 K-O keyboard, video, and mouse Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 103: P-T

    Network Controller Sideband Interface Open Compute Project C.4 P-T PCIe Peripheral Component Interconnect Express power distribution unit physical layer PMBUS power management bus Power OK pulse-width modulation Preboot Execution Environment Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 104 LAN SONCAP Standards Organization of Nigeria-Conformity Assessment Program solid-state drive Streaming SIMD Extension TACH tachometer signal Turbo Boost Technology Trusted Computing Group trusted cryptography module total cost of ownership Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 105: U-Z

    Voluntary Control Council for Interference by Information Technology Equipment Video Graphics Array VLAN virtual local area network voltage regulator-down VROC Virtual RAID on CPU WEEE waste electrical and electronic equipment Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.
  • Page 106 FusionServer 1288H V7 Server Technical White Paper C Acronyms and Abbreviations WSMAN Web Service Management Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd.

Table of Contents