1
2
" H "
Move the awning to the
Hold down the but-
desired "H" position.
ton and
4
5
2
sec.
Hold down both
count 2 movements;
buttons...
5
5
sec.
Hold down the but-
count 3 movements;
ton and
6
8
sec.
Hold down both but-
count 4 movements;
tons...
D.9 - "RDC" Function: adjustment of the motor traction force when closing
D
NOTES AND WARNINGS
• This function prevents the excessive traction of the canvas at the end of the closing manoeuvre. During the final phase of this manoeuvre, the function automatically
reduces the motor traction torque, based on the factory setting or the one adjusted by the installer with the following procedure.
• Warning! – This function is active with the factory setting but is not applicable if the limit switches are programmed with the manual procedure (D.6).
1
5
2
sec.
Hold down both
count 2 movements;
buttons...
 2
1 /
2 /
3 /
?
10
4 /
sec.
5 /
after about 10 seconds, the motor performs a num-
ber of movements equal to the number of pulses
entered.
(*) = Factory setting.
5
2
sec.
count 2 movements;
release the button.
5
Precisely ad-
justing the
"H" posi-
tion
release the
Press the buttons until you reach the desired position.
buttons.
3
release the button.
end
4
release the but-
tons.
2
Select the desired
option and program
it as follows
release the but-
tons.
3
5
sec.
Hold down the but-
count 3 movements;
ton and
3
5
sec.
Hold down the but-
ton and
 5
" H "
...
6
Select one of the following potions and
execute it:
• option A – to memorise the FIRST
"H" position.
• option B – to memorise a SUPPLE-
MENTARY "H" position.
6
On ANOTHER transmitter, which
has NOT been memorised: hold
down any button you wish;
5 OPTIONS:
x 1 = standard sensitivity (*)
x 2 = minimum sensitivity
0,5
x 3 = medium sensitivity
sec.
x 4 = maximum sensitivity
x 5 = function deactivated
Press and release the button the number of times indicated in the option you
have chosen;
end
3
release the but-
ton.
4
count 4 movements;
release the button.
end
4
count 4 movements.
MONO
Note – When performing the procedure, at
any time you can cancel it by keeping the n
and t keys pressed simultaneously for 4 sec-
onds. Otherwise, do not press any key and
wait 60 seconds for the motor to perform 6
movements.
 4