Download Print this page

Nice E FIT S 619 BD Instructions And Warnings For Installation And Use page 26

Tubular motor
Hide thumbs Also See for E FIT S 619 BD:

Advertisement

D.7 - SEMIAUTOMATIC programming of the UP ("0") and DOWN ("1") limit switches
D
MONO
NOTES AND WARNINGS
• Use this procedure solely for awnings with mechanical Up "0" limit switch stop.
• If, previously, the limit switches were programmed with the "Manual (D.6)" programming, to complete this procedure before proceeding with the "Total or partial de-
letion of the memory [A.4.1 (motor configured for ONE-WAY communication), B.4.1 (motor configured for TWO-WAY communication) or D.4.1 (motor configured for
ONE-WAY communication and OLD generation transmitter lacking the PRG and ESC keys) option 'A' or 'D']".
• After the limit positions have been programmed, the awning can be controlled by simply pressing the appropriate buttons on the control unit. The Up movement
will be limited when the awning impacts against the mechanical lock (box) in the Upper limit switch "0". With each impact, the height of this limit switch will be auto-
matically updated by the "Automatic limit switch update" function (paragraph 5.4). Conversely, the Down movement will be limited by the Lower limit switch "1" (limit
switch set by the installer at a desired point).
1
Command
an UP
movement
Hold down the button and...
 2
" 1 "
... release the button as soon as the awning
reaches position "1" ( DOWN limit switch).
4
5
sec.
Hold down the but-
count 4 movements;
ton and
6
Finely adjust-
ing the posi-
tion of limit
switch "1"
Press the buttons until you reach the desired position.
• Notes – When performing the procedure, at any time you can cancel it by keeping the n and t keys pressed simultaneously for 4 seconds. Otherwise, do not press
any key and wait 60 seconds for the motor to perform 6 movements. • After this programming, the s key will command the Raise manoeuvre and the t key will
command the Lower manoeuvre. During the Raising manoeuvre, the awning will be stopped by the impact against the mechanical blocks of the structure (= upper
limit switch "0"), while during the Lowering manoeuvre the awning will stop at the lower limit switch ("1") estabilished by the installer.
D.8 - Programming an INTERMEDIATE POSITION (position "H")
D
NOTES AND WARNINGS
• This procedure memorises an intermediate position (position "H") between the Up ("0") and Down ("1") limit switch positions. When the automation is being used,
after giving the intermediate position command, the system will automatically stop the awning at the programmed "H" position.
• Up to 30 "H" positions can be memorised if the motor is configured to operate in ONE-WAY mode, or up to 6 "H" positions if the motor is configured to operate in
TWO-WAY mode, in any desired position, provided that they are within the space delimited by the two limit switches. These positions can only be programmed after
the limit switch positions. Repeat this procedure for each position you wish to memorise.
• The first "H" position must be programmed using the buttons s+t, on the transmitter used to run the procedure itself. However, each subsequent position
"H" must be programmed using a button on another non-memorised transmitter.
• To change an existing "H" position, move the awning to the desired height and run this procedure; in step 06, however, press the button associated with the exist-
ing "H" position you are changing.
25 – English
" 0 "
... wait for the awning to be stopped when it
collides with the box (= UP limit switch = po-
sition "0").
3
5
sec.
Hold down the but-
count 2 movements;
ton and
4
release the button.
7
" 1 "
Hold down the button and
release the but-
Hold down the button and wait...
ton.
2
release the button.
5
5
sec.
Hold down the button and
count 2 movements;
3
5
sec.
count 3 movements;
2
continues
Command
an DOWN
movement
2
release the button.
end
release the button.
MONO
 6

Advertisement

loading