B.1 - Temporarily deactivating (and reactivating) motors you do not wish to program
B
BiDi
NOTES AND WARNINGS
• This procedure temporarily deactivates (for 5 minutes) only motors whose up and down limit switches have already been programmed.
B.2.1 - To temporarily deactivate motors you do not wish to program
1
= 5 sec
ESC
Hold down the but-
release it after 5 sec-
onds;
ton and
B.2.2 - To reactivate temporarily locked out motors
You can reactivate the motors in two ways:
1
After 5 minutes the
locked out motors are
automatically reactivat-
ed by the system.
Wait for 5 minutes ...
B.1 - Memorising ANOTHER TRANSMITTER (second, third, etc.)
B
NOTES AND WARNINGS
• The motor configured to operate in TWO-WAY mode can memorise up to 16 transmitters.
• To run procedures B.3 you must have a new transmitter to memorise and an old previously memorised transmitter. The two transmitters must have the "PRG" and
"ESC" buttons (like "ERA P" and "ERA W" transmitters).
• Procedures B.3 memorise all the new transmitter's buttons in "Mode I", with the same configuration as the old transmitter (for details about "Mode I" see par. 4.6.1).
1
(x 1)
PRG
OLD
On the OLD transmitter: Press
and release the button (1 time);
3
(x 1)
PRG
OLD
On the OLD transmitter: Press
and release the button (1 time);
" 0 "
ESC
you will see a brief down
movement and a movement
which stops the awning at
the Up limit "0".
end
... the system will then
move the awning to
the mid position.
2
2
NEW
count 2 movements;
On the NEW transmitter: hold
down the button and
4
2
NEW
On the NEW transmitter: Press
count 2 movements;
and release the button (1 time);
2
The system locks out only those motors whose limit
switches have already been programmed. It has no ef-
fect on motors which have not yet been programmed.
The deactivation is temporary and lasts for 5 min-
utes.
For a period of 5 minutes, the locked out motors will not
respond to commands.
1
During the 5 minute
period the locked out
motors can be reacti-
vated at any time by the
user.
During the 5 minutes, at
... hold down the
any time...
button and
= 5 sec
release it after 5 sec-
onds;
(x 1)
count 3 movements
(= transmitter
memorised).
end
= 10 sec
ESC
ESC
release it after 10
seconds;
BiDi
 3
2
count 2 movements;
end
3
end
the system will then
move the awning to
the mid position.
English – 14