Download Print this page

Nice E FIT S 619 BD Instructions And Warnings For Installation And Use page 18

Tubular motor
Hide thumbs Also See for E FIT S 619 BD:

Advertisement

C.1.2 - To program the DOWN limit switch ("1")
1
(x 1)
PRG
Press and release
count 2 movements.
the button (1 time);
 3
" 1 "
... release the button as soon as the awning
reaches position "1" ( DOWN limit switch).
C.2 - SEMIAUTOMATIC programming of the UP ("0") and DOWN ("1") limit switches
C
MONO BiDi
NOTES AND WARNINGS
• Use this procedure solely for awnings with mechanical Up "0" limit switch stop.
• If, previously, the limit switches were programmed with the "Manual (C.1)" programming, to complete this procedure before proceeding with the "Total or partial de-
letion of the memory [A.4.1 (motor configured for ONE-WAY communication), B.4.1 (motor configured for TWO-WAY communication) or D.4.1 (motor configured for
ONE-WAY communication and OLD generation transmitter lacking the PRG and ESC keys) option 'A' or 'D']".
• After the limit positions have been programmed, the awning can be controlled by simply pressing the appropriate buttons on the control unit. The Up movement
will be limited when the awning impacts against the mechanical lock (box) in the Upper limit switch "0". With each impact, the height of this limit switch will be auto-
matically updated by the "Automatic limit switch update" function (paragraph 5.4). Conversely, the Down movement will be limited by the Lower limit switch "1" (limit
switch set by the installer at a desired point).
1
Command
an UP
movement
Hold down the button and...
 2
... release the button as soon as the awning
reaches position "1" ( DOWN limit switch).
5
Finely adjust-
ing the posi-
tion of limit
switch "1"
Press the buttons until you reach the desired position.
17 – English
2
= 5 sec
2
Hold down the but-
release it after 5
ton and
seconds;
4
Finely adjust-
ing the posi-
tion of limit
switch "1"
Press the buttons until you reach the desired position.
Alternatively, for more accurate adjustment, run proce-
dure A.2.1, B.3 or D.2.1.
... wait for the awning to be stopped when it
collides with the box (= UP limit switch = po-
sition "0").
3
(x 1)
" 1 "
PRG
Press and release
the button (1 time);
6
" 1 "
Hold down the button and
2
count 2 movements.
" 1 "
Hold down the
button and
" 0 "
release the button.
4
= 5 sec
2
count 2 movements.
Hold down the but-
ton and
= 5 sec
release it after 5 seconds;
3
continues
Command
an DOWN
movement
Hold down the button and wait...
5
= 5 sec
release it after 5
seconds;
2
continues
Command
an DOWN
movement
Hold down the button and wait...
release it after 5 sec-
onds;
end
3
count 3 movements.
end
3
count 3 movements.
 5
2
count 2 movements.

Advertisement

loading