Taylor 0738 Operator's Manual page 46

Counter top heat treatment soft serve freezer
Table of Contents

Advertisement

OPERATOR CHECKLIST
Note: For machines equipped with an air filter, it
will be necessary to vacuum clean the filters on a
monthly schedule.
WARNING! Always disconnect
7
electrical power prior to cleaning the
condenser. Failure to follow this
instruction may result in electrocution.
If your machine is equipped with an
auxiliary refrigeration system, check the
auxiliary condenser for accumulation of dirt
and lint. A dirty condenser will reduce the
refrigeration capacity of the mix hopper.
Condensers must be cleaned monthly
with a soft brush. Never use screwdrivers
or other metal probes to clean between the
fins. Failure to comply may result in
electrocution.
If your machine is water-cooled, check the
water lines for kinks or leaks. Kinks can
occur when the machine is moved back
and forth for cleaning or maintenance
purposes. Deteriorated or cracked water
lines should be replaced only by a Taylor
service technician.
Winter Storage
If the place of business is to be closed during
the winter months, it is important to protect the
freezer
by
following
particularly if the building is subject to freezing
conditions.
Disconnect the freezer from the main power
source to prevent possible electrical damage.
On water cooled freezers, disconnect the water
supply. Relieve pressure on the spring in the
water valve. Use air pressure on the outlet side
to blow out any water remaining in the
condenser.
This
Failure to follow this procedure may cause
severe and costly damage to refrigerant system.
Your local Taylor Distributor can perform this
winter storage service for you.
7-2
certain
precautions,
is
extremely
important.
Wrap detachable parts of the freezer such as
beater, blades, freezer door, pump and place
them in a protected dry place. Rubber trim parts
and gaskets can be protected by wrapping them
with moisture-proof paper. All parts should be
thoroughly cleaned of dried mix or lubrication
which attract mice and other vermin.
It is recommended that an authorized service
technician perform winter storage draining, to
insure all water has been removed. This will
guard against freezing and rupturing of the
components.
Model 0738
Operator Checklist

Advertisement

Table of Contents
loading

Table of Contents