Hopper Agitation Adjustment in Auto
Mode
1. With the machine filled with fresh mix, press
the Auto button to start the freezing cycle.
2. Press
the
Auto
simultaneously for a few seconds until the
adjustment menu appears on the display.
3. The first menu item allows you to adjust the
consistency of the product. Press the OK
button to confirm the displayed value and
switch to the next entry.
4. Subsequent parameters allow the operator to
change
the operating times (MIXING ON) and pause
(MIXING OFF) of the hopper agitator motor
during the Auto mode.
5. Press the Up Arrow button to increase the
time; press the Down Arrow button to
decrease the time.
6. Press OK button to confirm the new selected
values. Press C button to erase the new
values.
Operating Procedures
and
Option
buttons
Model 0738
OPERATING PROCEDURES
Hopper Temperature Adjustment in
Standby Mode
1. With the machine filled with a fresh mix,
press the Standby button.
2. Press the Standby and Option buttons
simultaneously for a few seconds until the
adjustment menu appears on the display.
3. The first menu item allows the operator to
change the temperature of the mix in the
hopper during the Standby mode between
32°F (0°C) and 41°F (5°C).
4.
4. Press the Up Arrow button to increase the
temperature; press the Down Arrow button to
decrease the temperature.
5. Press OK button to confirm the new
selected value. Press C button to erase the
new value.
6. Press the OK button to confirm the other
menu items and exit the menu by saving the
changes.