Taylor 0738 Operator's Manual page 28

Counter top heat treatment soft serve freezer
Table of Contents

Advertisement

USER INTERFACE
ALARM — PROBE CBL INTERRUPTED The
barrel evaporator thermistor is open; switch off the
machine. Call your Taylor service technician.
ALARM — PROBE CBL SHORT CIRC. The
barrel evaporator thermistor has shorted; switch
5
off the machine. Call your Taylor service
technician.
ALARM — PROBE CTS INTERRUPTED The
CTS thermistor is open; switch off the machine.
Call your Taylor service technician.
ALARM — PROBE CTS SHORT CIRC. The CTS
thermistor has shorted; switch off the machine.
Call your Taylor service technician.
ALARM — THERMAL OVERLOAD Press the
STOP button and wait 5 minutes for the machine
to cool. Restart in AUTO. If the alarm continues,
call your Taylor service technician.
ALARM — PHASES L2-L3 SWITCHED Press
the STOP button and switch off the machine. Call
your Taylor service technician.
ALARM — SWITCH PHASE / NEUTRAL Press
the STOP button and switch off the machine. Call
your Taylor service technician.
ALARM — NO CURRENT SIGNAL OR
DEFECTIVE TRANSFORMER Press the STOP
button and switch off the machine. Call your
Taylor service technician.
ALARM — DEVICE KO Switch off the
machine. Call your Taylor service
technician.
ALARM — COMMUNICATION ERROR Switch
off the machine. Call your Taylor service
technician.
ALARM — BATCH TIME OUT The
compressor run time exceeded the 120-
minute timer. Replace the scraper blades
during the next brush cleaning. If that does
not resolve the fault, call your Taylor service
technician.
Lockout History
5-8
The LOCKOUT HISTORY screen displays a
history of the last 200 soft locks, hard locks and
aborted Heat cycles. The most recent lockout is
displayed on screen 1. The data and time
description is displayed on each screen. Press the
Arrow buttons to display the next screen; press OK
or C button to return to the main menu.
The following variable messages which will
appear, along with an explanation of the
corrective action:
Faults occurring while in Heat mode
LOCK HT — (HEAT MODE FAILURE) The
maximum allowable heat mode time
exceeded 90 minutes.
LOCK CL — (COOL MODE FAILURE) The
maximum allowable cool mode time exceeded
120 minutes.
LOCK TT — (TOTAL TIME FAILURE) The
maximum allowable total heat treatment time
exceeded 4 hours.
LOCK OP — (OPERATOR ABORT) The
operator has aborted the heat treatment cycle.
WARN. PS — (POWER FAIL IN H/C) A
power failure occurred during the heat
treatment cycle.
WASHING REQUIRED — (BRUSH CLEAN
TIMEOUT) The total days in operation
exceeded the brush clean cycle setting.
Faults Occurring While in Auto mode
HP 5C 4H — The mix temperature in the
hopper was above 41°F (5°C) more than four
hours.
BR 5C 4H — The mix temperature in the barrel
was above 41°F (5°C) more than four hours.
HP 5C PF — The mix temperature in the hopper
was above 41°F (5°C) more than four hours
following a power failure.
BR 5C PF — The mix temperature in the barrel
was above 41°F (5°C) more than four hours
following a power failure.
Model 0738
User Interface