Taylor 0738 Operator's Manual page 41

Counter top heat treatment soft serve freezer
Table of Contents

Advertisement

spring, and the O-ring. Remove the cover,
the gears, and the O-rings. Remove the feed
tube, feed tube coupling, duck-bill valve, and
the O-rings.
Note: Never use any tool to remove the gears
from the pump body.
5. Disassemble the freezer door. Remove
the door O-ring, pivot pin, draw valve,
draw handle, counter-beater with
bushings, and O-rings.
6. Remove the front drip shelf, drip tray, and
splash shield.
7. Remove the drip pan.
8. Take all parts to the sink for cleaning.
9. Note: If the drip pan is filled with an
excessive amount of mix, it is an
indication that the driveshaft seal should
be replaced or properly lubricated.
Brush-Cleaning
1. Prepare an approved 100 PPM sanitizing
solution (example: 2-1/2 gal [9.5 L] of Kay-5
or 2 gal. [7.6 L] of Stera-Sheen
water and follow the manufacturer's
specifications.
2. Thoroughly brush-clean all disassembled parts
in the cleaning solution, making sure all
lubricant and mix film is removed. Make sure
to brush all surfaces and holes, especially the
holes in the pump components and the draw
valve hole in the freezer door.
Place the parts on a clean, dry surface to
air-dry overnight.
3. Return to the freezer with a small amount of
cleaning solution. Using a brush, clean the
driveshaft opening at the back of the freezing
cylinder.
4. Using the brush, clean the mix pump
drive hub opening in the rear wall of the
mix hopper.
5. Wipe all exterior surfaces of the freezer with a
clean, sanitized towel.
Operating Procedures
®
®
). Use warm
Model 0738
OPERATING PROCEDURES
6
6-11

Advertisement

Table of Contents
loading

Table of Contents