• Check the gas inlet-pressure (both when the appliance is off and when it burns
at maximum) and the burner pressure.
• Check if the overpressure hatches are correctly positioned and check if the
gasket seals are properly positioned under the hatches.
• Check the complete concentric fl ue system including the outlet construction.
A camera can be used to inspect the whole length of the fl ue gas outlet and the
combustion air intake. Also check that all connections are secure.