INSTALLATION INSTRUCTIONS &
MANUAL FOR MAINTENANCE
HORIZON BELL
XL 3
Gas fi res with closed combustion system
Bellfi res wishes you many cosy evenings with your new Bellfi res gas fi re
This document is an essential part of your gas fi re.
Read it carefully before installation and maintenance of the
gas fi re and keep it in a safe place!
Serial number:
Production date:

Advertisement

Table of Contents
loading

Summary of Contents for Bellfires Horizon Bell XL 3

  • Page 1 INSTALLATION INSTRUCTIONS & MANUAL FOR MAINTENANCE HORIZON BELL XL 3 Gas fi res with closed combustion system Bellfi res wishes you many cosy evenings with your new Bellfi res gas fi re This document is an essential part of your gas fi re. Read it carefully before installation and maintenance of the gas fi...
  • Page 3 Bellfi res English BELLFIRES GAS FIRE WITH CLOSED COMBUSTION SYSTEM: Horizon Bell XL 3 (HBXL3) Installation instructions...
  • Page 4 Bellfi res English Installation instructions...
  • Page 5: Table Of Contents

    Bellfi res English CONTENTS Page 1. INSTALLATION INSTRUCTIONS .............. 2. MAINTENANCE ..................3. FAULTS ...................... 4. DISMANTLING / ASSEMBLING OF THE GLASS ........5. ELECTRICAL DIAGRAM ................6. DIMENSIONS .................... 7. TECHNICAL DETAILS/REGULATIONS ............ 8. REPLACEMENT PARTS LIST ..............9. DISPOSAL OF PACKAGING AND APPLIANCE ........IMPORTANT The installation must only be carried out by a “Gas Safe Register”...
  • Page 6 Bellfi res English Installation instructions...
  • Page 7: Installation Instructions

    Bellfi res English INSTALLATION INSTRUCTIONS 1.1 GENERAL The gas fi re must be positioned and connected as a “room sealed system” (balance fl ue) appliance by a “Gas Safe Register” registered gas installation engineer in accordance with the following installation instructions, nationally and locally applicable regulations (see “Technical Details/ Regulations”...
  • Page 8 Bellfi res English The appliance can be fi tted with a convection package as an optional extra. This is a “convection jacket” (convection casing) for around (or above) the appliance, two fl exible aluminium pipes and two built-in convection vents. This enables hot air to be circulated into the room.
  • Page 9 Bellfi res English OPTIONS AND ACCESSORIES The following options and accessories can be supplied by your dealer: Part no Option Convection Horizon Bell XL 3 330293 • 1x Convection casing 312829 • 1x Convection set General 330361 Set of high adjustable feet (4 pieces)
  • Page 10 Bellfi res English PREPARATION FOR INSTALLATION The following preparation must be carried out before the gas fi re can be installed. 1.5.1 Instructions for positioning the outlet 1.5.1.1 Positioning the outlet for correct operation: Roof-mounted outlet: >0.5 m Figure 1: Roof-mounted outlet This must be positioned at least 0.5 m from the roof edge;...
  • Page 11 Bellfi res English 1.5.1.2. Positioning the outlet to avoid affecting the surrounding area All listed “distances” in this section are no more than guidelines. For the exact minimum “distances”, please consult your national and local directives. “Distance” = minimum distance required for positioning of the outlet to avoid adverse effects with respect to: A.
  • Page 12 Bellfi res English Wall-mounted outlet: To avoid adverse effects Distance: outlet - A, B or C At walls in buildings with staggered Not permitted if A, B, or C are located heights. above the outlet. On a wall - general. (*) Above the outlet: >2 m Below the outlet:...
  • Page 13 Bellfi res English GENERAL SERVICES 1.6.1 The Fume Channel/Combustion Air Intake The combined fume channel and combustion air intake requires one of the following concentric fl ue system confi gurations. Important: Due to the high temperature of the outer walls (approx.
  • Page 14 Ø130-Ø200 mm Width: Width: 2.0 - 4.0 m B = 30 mm B = 65 mm Horizon Bell XL 3 Width: Width: 4.0 - 12.0 m B = 40 mm B = 80 mm Figure 4: Vertical roof-mounted outlet without bend...
  • Page 15 Bellfi res English 14, 15 10, 11, 12, 13 (100) Item descriptions: see 1.6.2 Assemble restriction plate: Appliance: Distance Y Distance X (*) Distance Y Concentric Concentric (min.-max.) (min.-max.) (min.-max.) connection connection on appliance is on appliance is Ø100-Ø150 mm Ø130-Ø200 mm Horizon Bell Width:...
  • Page 16 Ø100-Ø150 mm Ø130-Ø200 mm Width: Width: 2.0 - 4.0 m B = 30 mm B = 65 mm Horizon Bell XL 3 Width: Width: 4.0 - 12.0 m B = 40 mm B = 80 mm Figure 6: Vertical chimney outlet using an existing lined chimney (Flexible Ø100 mm and/or rigid Ø100 mm / Ø150 mm)
  • Page 17 Bellfi res English > 45° 10, 11, 12, 13 (100) Item descriptions: see 1.6.2 Assemble restriction plate: Appliance: Distance Y (*) Distance X (*) Distance Y Concentric Concentric (min.-max.) (min.-max.) (min.-max.) connection connection on appliance is on appliance is Ø100-Ø150 mm Ø130-Ø200 mm Horizon Bell Width:...
  • Page 18 Ø100-Ø150 mm Ø130-Ø200 mm Width: Width: 2.0 - 4.0 m B = 30 mm B = 65 mm Horizon Bell XL 3 Width: Width: 4.0 - 12.0 m B = 40 mm B = 80 mm Figure 8: Vertical chimney outlet using an existing unsound lined chimney or when no chimney liners are present (Flexible Ø100 mm / Ø150 mm)
  • Page 19 Bellfi res English > 45° (100) Item descriptions: see 1.6.2 Assemble restriction plate: Appliance: Distance Y (*) Distance X (*) Distance Y Concentric Concentric (min.-max.) (min.-max.) (min.-max.) connection connection on appliance is on appliance is Ø100-Ø150 mm Ø130-Ø200 mm Horizon Bell Width: 1.0 - 11.0 m 0 - 3.0 m...
  • Page 20 (min.-max.) appliance is Ø130-Ø200 mm 2.0 - 3.0 m 0 - 0.6 m Horizon Bell XL 3 3.0 - 4.0 m 0 - 1.6 m Figure 10: Horizontal wall termination ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION...
  • Page 21 Ø130-Ø200 mm 0.5 - 1.0 m 0 - 0.6 m Width: B = 40 mm Horizon Bell XL 3 1.0 - 2.0 m 0 - 2.6 m Figure 11: Horizontal wall termination ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION...
  • Page 22 (min.-max.) appliance is Ø130-Ø200 mm 0.5 - 1.0 m 0 - 1.6 m Horizon Bell XL 3 1.0 - 3.0 m 1.6 - 4.6 m Figure 12: Horizontal wall termination ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION...
  • Page 23 Bellfi res English RIGID CONCENTRIC FLUE Ø130 mm - Ø200 mm SYSTEM CONNECTION POSSIBILITIES and with wall outlet Ø100 mm - Ø150 mm Appliance: Concentric fl ue connection Ø130-Ø200 mm Wall 110, 111, Termination Position 110, 113 110, 111, 113 Item descriptions: see 1.6.2 Assemble restriction plate:...
  • Page 24 Concentric connection on (min.-max.) (min.-max.) appliance is Ø130-Ø200 mm 0 - 0.5 m 0 - 0.6 m Horizon Bell XL 3 0.5 - 3.0 m 0 - 3.6 m 1.0 - 3.0 m 3.6 - 8.6 m Figure 14: Horizontal wall termination...
  • Page 25 Ø100 mm internal fl exible stainless steel gas vent chimney liner AISI 316TI. Ø150 mm internal fl exible stainless steel gas vent chimney liner AISI 316TI. AVAILABLE COMPONENTS FOR THE BELLFIRES (M&G) CONCENTRIC FLUE SYSTEM Ø100 mm - Ø150 mm...
  • Page 26 Bellfi res English BELLFIRES Color(*) Application FIG. ART. / DESCRIPTION ORDER RVS antr. RIGID FLEX Twin-wall balanced fl ue elbow 45°, 302298 incl. 302295 Vertical (roof) termination kit, L = 1360 mm (vertical), incl. 302212 Adjustable roof fl ashing. Roof pitch 20° - 45° (**), with lead fl...
  • Page 27 Bellfi res English BELLFIRES Color(*) Application FIG. ART. / DESCRIPTION ORDER RVS antr. RIGID FLEX 302189 Ceiling plate for transition Ø100 mm / Ø150 mm rigid - Ø100 mm (fl ex.). 302278 Stainless steel adapter piece (100) from fi re to fl exible, Ø100 mm external (rigid) x Ø107 mm internal...
  • Page 28 Bellfi res English BELLFIRES Color(*) Application FIG. ART. / DESCRIPTION ORDER RVS antr. RIGID FLEX 302302 Concentric pipe with gauging orifi ce, L = 165 mm, incl. 302303 90° concentric bend with inspection panel, incl. 321948 Universal wall / fl oor support Ø150 mm...
  • Page 29 Bellfi res English AVAILABLE COMPONENTS FOR THE BELLFIRES (M&G) CONCENTRIC FLUE SYSTEM Ø130 mm - Ø200 mm BELLFIRES Color(*) Application ART. / DESCRIPTION ORDER RVS antr. RIGID FLEX 302319 Concentric reduction of Ø130 / Ø200 mm Ø100 / Ø150 mm 302308 Twin-wall balanced fl...
  • Page 30 Bellfi res English BELLFIRES Color(*) Application FIG. ART. / DESCRIPTION ORDER RVS antr. RIGID FLEX 302311 : Stainless steel locking band Ø200 mm, quick-fastening 302248 : Silicone seal Ø200 mm 302251 : Wall strap 302250 Set of ceiling fi nishing plates /...
  • Page 31 Bellfi res English AVAILABLE COMPONENTS FOR THE POUJOULAT PGI CONCENTRIC FLUE SYSTEM Ø100 mm - Ø150 mm POUJOULAT FIG. ART. / DESCRIPTION ORDER 37100403 Twin-wall balanced fl ue pipe, L = 250 mm 37100404 Twin-wall balanced fl ue pipe, L = 450 mm 37100405 Twin-wall balanced fl...
  • Page 32 Bellfi res English POUJOULAT FIG. ART. / DESCRIPTION ORDER Twin-wall balanced fl ue elbow 30° 37100411 Twin-wall balanced fl ue elbow 15° 37100401 37100654 Vertical (roof) termination kit, L = 140 mm 45150171 Roof fl ashing, suitable for a brick roof, with a roof pitch of 15°- 30°...
  • Page 33 Bellfi res English POUJOULAT FIG. ART. / DESCRIPTION ORDER 45150169 Roof fl ashing for existing chimney or fl at roof 37100610 Horizontal (wall) termination kit, L = min. 365 mm / max. 585 mm 45150076 Stainless steel locking band Ø150 mm, quick-fastening 45150072 Wall strap, Ø150 mm...
  • Page 34 Bellfi res English POUJOULAT FIG. ART. / DESCRIPTION ORDER 45150165 Roof support, (universal) Ø150 mm 45150081 Floor support, (universal) Ø150 mm 37100611 Adapter: Bellfi res Ø100-150 mm Poujoulat PGI Ø100-150 mm (Appliance 100/150 Poujoulat PGI 100/150) 37100614 Adapter: Bellfi res Ø130-200 mm Poujoulat PGI Ø100-150 mm (Appliance 130/200 Poujoulat PGI...
  • Page 35 Bellfi res English AVAILABLE COMPONENTS FOR THE POUJOULAT PGI CONCENTRIC FLUE SYSTEM Ø130 mm - Ø200 mm POUJOULAT FIG. ART. / DESCRIPTION ORDER 37130403 Twin-wall balanced fl ue pipe, L = 250 mm Twin-wall balanced fl ue pipe, 37130404 L = 450 mm Twin-wall balanced fl...
  • Page 36 Bellfi res English POUJOULAT FIG. ART. / DESCRIPTION NOR. ORDER Twin-wall balanced fl ue elbow 30° 37130411 Twin-wall balanced fl ue elbow 15° 37130401 37130610 Horizontal (wall) termination kit, L = min. 425 mm / max. 585 mm 45200076 Stainless steel locking band Ø200 mm, quick-fastening 45200072 Wall strap, Ø200 mm...
  • Page 37 Bellfi res English POUJOULAT FIG. ART. / DESCRIPTION ORDER 37130407 Concentric pipe with inspection opening, L = 250 mm 45200165 Roof support, (universal) Ø200 mm 45200081 Floor support, (universal) Ø200 mm 37130615 Adapter: Bellfi res Ø130-200 mm Poujoulat PGI Ø130-200 mm (Appliance 130/200 Poujoulat PGI 130/200)
  • Page 38 Bellfi res English AVAILABLE COMPONENTS FOR THE ONTOP METALOTERM US CONCENTRIC FLUE SYSTEM Ø100 mm - Ø150 mm ONTOP FIG. ART. / DESCRIPTION ORDER USA 10 Adapter for Bellfi res appliances with Ø100-Ø150 mm concentric connection US 25 10 Twin-wall balanced fl ue pipe, L = 250 mm US 50 10 Twin-wall balanced fl...
  • Page 39 Bellfi res English ONTOP FIG. ART. / DESCRIPTION ORDER Twin-wall balanced fl ue elbow 15° USB 15 10 USDVC2 10 Vertical (roof) termination kit, L = 375 mm, incl. USSR 10 Storm collar Ø150 mm USLS 10 Adjustable roof fl ashing. Roof pitch 20°...
  • Page 40 Bellfi res English ONTOP FIG. ART. / DESCRIPTION ORDER USKB 10 : Locking band, quick-fastening USAB 10 : Cover band, screw-fastening USMB 10 Wall strap, adjustable USEB 10 Fitting bracket USCP 10 Set of ceiling fi nishing plates / Fire stops / Centring plates USDQ 10 Roof support...
  • Page 41 Bellfi res English ONTOP FIG. ART. / DESCRIPTION ORDER USSAN2 10 Bottom renovation set USKBS 10 Locking band, screw-fastening USI 10 Concentric pipe with inspection panel, L = 250 mm USEM 10 Concentric pipe with gauging orifi ce, L = 150 mm USBI 10 90°...
  • Page 42 Bellfi res English ONTOP FIG. ART. / DESCRIPTION ORDER USVG 10 13 Concentric reduction of Ø100-Ø150 mm Ø130-Ø200 mm AVAILABLE COMPONENTS FOR THE ONTOP METALOTERM US CONCENTRIC FLUE SYSTEM Ø130 mm - Ø200 mm ONTOP FIG. ART. / DESCRIPTION ORDER USA 13 Adapter for Bellfi...
  • Page 43 Bellfi res English ONTOP FIG. ART. / DESCRIPTION ORDER Twin-wall balanced fl ue elbow 45° USB 45 13 Twin-wall balanced fl ue elbow 30° USB 30 13 Twin-wall balanced fl ue elbow 15° USB 15 13 USDVC2 13 Vertical (roof) termination kit, L = 375 mm, incl.
  • Page 44 Bellfi res English ONTOP FIG. ART. / DESCRIPTION ORDER USDP 13 Roof fl ashing for existing chimney or fl at roof USDPAL 13 Roof fl ashing - Aluminium for existing chimney or fl at roof USDHC4 13 Horizontal (wall) termination kit, L = 475 mm (horizontally adjustable)), incl.
  • Page 45 Bellfi res English ONTOP FIG. ART. / DESCRIPTION ORDER USDQ 13 Roof support USSAN 13 Renovation set USSAN1 13 Top of renovation set USSAN2 13 Bottom renovation set USKBS 13 Locking band, screw-fastening USI 13 Concentric pipe with inspection panel, L = 250 mm USEM 13 Concentric pipe with gauging orifi...
  • Page 46 Bellfi res English ONTOP FIG. ART. / DESCRIPTION ORDER USBI 13 90° concentric bend with inspection panel Rosette smooth Ø200 mm USR 13 Wall plate large Ø200 mm, 350 mm USMPG 13 Spacer bracket ASAH 13 Concentric reduction of Ø130-Ø200 mm USVG 13 10 Ø100-Ø150 mm •...
  • Page 47 Bellfi res English 1.6.3 Gas connection Operation (gas regulating block (and receiver)) outside the appliance (in the operating unit): The gas connection is situated where the operating unit is built in near to the appliance. Use only gas piping with a minimum diameter of 1/2” and a shut-off valve. 1.6.4 Operating unit If the appliance is fi...
  • Page 48 Bellfi res English Never position the appliance directly against the rear wall, but always place an nonfl ammable insulation plate, at least 12 mm thick, between the appliance and the rear wall, with free space on either side of 2 cm. (Total ± 5 cm.) The rear wall must be made of nonfl...
  • Page 49 Bellfi res English Figure 16: Appliance installed in ventilated chimney breast Horizontal outlet of the fl ue gas exhaust /combustion air supply via the wall. Fitted with the options / accessories: • convection package (= convection casing and 1x convection set) •...
  • Page 50 Bellfi res English Figure 17: Appliance installed in ventilated chimney breast Vertical outlet of the fl ue gas exhaust / combustion air supply via the roof. Fitted without convection package Inlet opening (appliance) convection air Inlet opening (grate) (chimney breast) convection air Natural convection in the chimney breast Outlet opening (grate) (chimney breast) convection air (2x) Concentric fl...
  • Page 51 Bellfi res English When fi tting the appliance, it can be levelled with the adjustable feet. These adjustable feet can be reached via the openings (4x), after removing the protec- tive covers, in the corners of the fl oor of the combustion chamber. The fl...
  • Page 52 Bellfi res English Position the gas supply pipe such that it can be easily mounted after installation. Because the control system is outside the appliance, the gas pipe must lead to where the operating unit (built in), the gas regulating block (and the receiver) assembly are fi...
  • Page 53 Bellfi res English 1.7.1 Connecting the gas Important: During gas connection, take care not to twist the gas regulating block. Make sure that both the gas regulating block and the supply pipes are not subjected to stresses. Appliance with operation in the separate operating unit (built in or otherwise):. •...
  • Page 54 Bellfi res English Remote control Gas regulating block and receiver in operating unit Gas regulating block Gas supply connection 3/8” - Ø12 mm insertion Burner piping connection Ø8 mm insertion Thermocouple connection M 10x1 mm insertion Pilot light piping connection Ø4 mm insertion Receiver Piezo cable connection Figure 19: Remote control: Gas regulating block and receiver in operating unit...
  • Page 55: Remote Control

    Bellfi res English Remote control The photo below shows how the piping for a remote control gas regulating block must be fi tted. Pilot Gas Adjustment Maximum Rate (with Screwdriver) Adjustment Screw Motor-knob Operating-Knob (Tab 2,8 x 0,8 mm) Connection piezo cable (Hand Control) Side-inlet Thermo Unit Connection...
  • Page 56 Bellfi res English Operating-Knob Motor-knob (Remote control ↔ Hand control) Connection Microswitch Piezo Igniter (Hand control) Piezo Igniter (Hand control) “O I” Switch Connection 8-Wire Receiver Jack Pilot Gas Figure 21: Gas regulating block Remote control Hand control Gas regulating block in operating unit The photo below shows how the piping for a hand control gas regulating block must be fi...
  • Page 57 Bellfi res English Appliance with operation in the separate operating unit (built in or otherwise). • Gas control block and piping supplied as an pre-assembly. First detach the bracket with the gas control block from the appliance. Fit the separate control unit max. 50 cm from the appliance. Fit the receiver in the top of the control unit.
  • Page 58 Bellfi res English The optional mantle iron is intended for supporting the brickwork above the hearth. The mantle iron must rest on the brickwork on both sides so that upward building is possible. The brickwork therefore must not rest on the fi replace; there must be approx. 3 mm clearance in connection with the weight.
  • Page 59 Bellfi res English Remove the glass according to the instructions in chapter 4; DISMANTLING / ASSEMBLING OF THE GLASS. 1.7.5.1 Ceramic log set + chips of wood + embers + vermiculite granules 1 Place the ceramic mat on the burner in such a way that the holes in the mat are in line with the burner openings.
  • Page 60 4 Place the logs on the burner: Natural gas-burner Propane / Butane-burner Appliance see fi gure: see fi gure: Horizon Bell XL 3 Keep the burner orifi ces unblocked !!! 5 Place the chips of wood around the burner. Installation instructions...
  • Page 61 Bellfi res English Logs: Log no Log no. Log no Log no Log no Log no Log no Log no Installation instructions...
  • Page 62 Embers must not be placed next to the pilot light burner Keep the burner orifi ces unblocked! Figure 22: Log set Horizon Bell XL 3 Position natural gas burner Embers must not be placed next to the pilot light burner Keep the burner orifi...
  • Page 63 2 Spread the pebbles over the whole burner bed (burner and grid around the burner). Make sure that the pilot light remains free. Horizon Bell XL 3 see fi gure 25 IMPORTANT: Open area, in order to ensure free accessibility of the pilot fl...
  • Page 64 Keep the burner orifi ces unblocked! Figure 25: Marble pebbles Horizon Bell XL 3 Position natural gas and propane/butane burner Important: • Do not place any marble pebbles in front of the pilot light.
  • Page 65 Bellfi res English Important: Ensure that the correct fl ue gas restriction plate is mounted. Use of the correct fl ue gas restriction plate will provide optimum effi ciency, fl ame effect and combustion. Mounting an incorrect fl ue gas restriction plate can result in damage to the gas fi...
  • Page 66 Bellfi res English The following restriction plates are supplied: Concentric fl ue connection appliance [Ø130 - 200 mm] [Ø100 - 150 mm] Restriction plate: Horizontal wall outlet Roof-mounted outlet Width: B = 30 mm Width: B = 40 mm B = 40 mm Width: B = 50 mm B = 50 mm...
  • Page 67: Maintenance

    Bellfi res English MAINTENANCE 2.1 ANNUAL MAINTENANCE It is essential that the appliance, the complete concentric fl ue system (where possible) and the outlet are cleaned and inspected annually by a recognised fi tter/gas specialist. The safe operation of the appliance will thus remain guaranteed.
  • Page 68: Faults

    Bellfi res English FAULTS POSSIBLE REASONS Possible reasons for the gas fi re going out are: • The concentric fl ue system is not installed according to one of the methods detailed in Paragraph 1.6. • An incorrect “fl ue gas restriction plate” is fi tted. •...
  • Page 69: Dismantling / Assembling Of The Glass

    Bellfi res English DISMANTLING / ASSEMBLING OF THE GLASS 4.1 HORIZON BELL XL 3 FLOATING FRAME Dismantling of the glass: - Horizon Bell XL 3 - Use the hook supplied (see photo) for Floating Frame opening the frame and the glass.
  • Page 70 Bellfi res English stud (right) - Detail of the stud (right). Place paperboard on the chimney breast, under the frame. This helps prevent damage. - Dismantle the safety strip from the frame. Installation instructions...
  • Page 71 Bellfi res English - Carefully tilt the frame and the window - Take hold of the frame and the glass forwards. clamped together and pull these Note ! : Frame and window are upwards. two separate parts ! - Frame and glass are now removed from the appliance. Assembling of the glass: The assembly of the glass takes place in reverse order.
  • Page 72 Bellfi res English 4.2 HORIZON BELL XL 3 HIDDEN DOOR Dismantling of the glass: - Horizon Bell XL 3 Hidden Door. - Use the hook supplied for opening the frame (including glass). - Use the hook to pull the frame at the top forward and hold the frame fi rmly.
  • Page 73 Bellfi res English - With the hook, pull the thin, metal spring strips on the top left and right from the studs on the frame. - Dismantle the safety strip from the frame. Note ! : When loosening the frame and after it has been loosened, support it with your hand to prevent it falling forward ! Installation instructions...
  • Page 74 Bellfi res English - Carefully tilt the frame and the glass forwards at the top. Prevent damage by laying paperboard on the chimney breast, under the frame. Pull the frame upwards and remove it from the appliance. Assembling of the glass: The assembly of the glass takes place in reverse order.
  • Page 75: Electrical Diagram

    Bellfi res English ELECTRICAL DIAGRAM Operating-Knob Motor-knob Gas regulating block “black” Thermo - “O I” Switch current “red” Interrupter Block 8 Wire Connecting Cable cable 2 cable 1 Thermo- Antenna Ignition cable couple “red” “yellow” SPARK RECEIVER SPARK SW TC ON/OFF Switch Thermocurrent interrupter Block...
  • Page 76: Dimensions

    Bellfi res English DIMENSIONS HORIZON BELL XL 3 6.1.1 HORIZON BELL XL 3 - Hidden Door Installation instructions...
  • Page 77 Bellfi res English 6.1.2 HORIZON BELL XL 3 - Floating Frame Installation instructions...
  • Page 78 Fitted with the options: - Convection casing - High adjustable feet 6.2.1 HORIZON BELL XL 3 - Hidden Door * With the high adjustable feet (option), the appliance can be installed till 350 mm above the fl oor. Installation instructions...
  • Page 79 Bellfi res English 6.2.2 HORIZON BELL XL 3 - Floating Frame * With the high adjustable feet (option), the appliance can be installed till 350 mm above the fl oor. Installation instructions...
  • Page 80 Bellfi res English OPERATING UNIT Installation instructions...
  • Page 81: Technical Details/Regulations

    National installation regulations: Gas safety installation and use regulations 1984 plus all relevant safety and building regulations concerning fi re installation Model : HORIZON BELL XL 3 Country : GB; Great Britain/IE; Ireland : GB; Great Britain/IE; Ireland Product identifi cation no...
  • Page 82 Bellfi res English Model : HORIZON BELL XL 3 Country : GB; Great Britain/IE; Ireland : GB; Great Britain/IE; Ireland Batteries remote control - Receiver : 4x 1.5V AA : 4x 1.5V AA - Hand-transmitter : 1x 9V block : 1x 9V block...
  • Page 83: Replacement Parts List

    Nut; Ø8 mm, compression elbow main burner 326054 Olive; Ø8 mm, compression elbow main burner 330292 Glass Horizon Bell XL 3 Hidden Door (1440 x 399 x 4 mm) 330291 Glass Horizon Bell XL 3 Floating Frame (1432 x 405 x 4 mm) Installation instructions...
  • Page 84 Bellfi res English Logs - Chips of wood - Embers - Vermiculite granules - Marble pebbles Installation instructions...
  • Page 85: Disposal Of Packaging And Appliance

    Bellfi res English DISPOSING OF PACKAGING AND APPLIANCE The appliance comes in recyclable packaging. This can include: • Cardboard • Wood • Plastic • Paper Such materials must be disposed of responsibly, in line with local regulations. Batteries should be disposed of as chemical waste. Batteries must be disposed of responsibly, in line with local regulations.
  • Page 86 Bellfi res English Installation instructions...