Select Message Length - Newland EM1300 Integration Manual

1d barcode scanning engine
Table of Contents

Advertisement

Symbols
COOP25(Japanese Matrix 2 of 5)

Select Message Length

It is used to program the valid reading length of COOP25. The engine will
send an error beep, if the decoded data length does not match the valid length.
COOP25 Message Length is defined by "Min. Message Length" and
"Max. Message Length ".
Min Message Length
【Pro CMD:99911706】
1D bar code Message Length should not exceed 255 bytes. If Max Message Length is less
than Min Message Length, it means the engine will only support barcodes of the two lengths.
If Max Message Length is equal to Min Message Length, the engine will only support bar-
codes of the length.
To set Min Message Length of COOP25 to 8 bytes and the Max Message Length to 12
bytes. Read these programming code:
1. "Code Programming ON"
2. "Select Min Message Length"
3. Digit Code "8", see Digit Code (Appendix Pxxx)
4. "Save Programming", see Digit Code (Appendix Pxxx)
5. "Select Max Message Length"
6. Digit Code "1"
7. Digit Code "2"
8. "Save Programming"
9. "Code Programming OFF"