Symbologies
Code 128

Select Message Length

It is used to program the valid reading length (bytes) of Code 128. The engine will produce an
error beep, if the data length captured does not match the valid reading length.
Code 128 Message Length is defined by "Min. Message Length" and "Max. Message Length".
Min Message Length (default: 1)
【Pro CMD: 0400030 】
1D bar code Message Length should not exceed 127 bytes.
Max Message Length should not be shorter than Min Message Length.
To read a fixed length Code 128, Please program Max & Min Message Length to the same value.
Program Code 128, Min Message Length 8 bytes, Max Message Length 12 bytes.
1.
2.
3.
4.
5.
6.
7.
8.
9.
nlscan.com
"Code Programming ON"
"Select Min Message Length"
Digit code "8", see Digit Code
"Save Programming", see Digit Code
"Select Max Message Length"
Digit code "1"
Digit code "2"
"Save Programming"
"Code Programming OFF"
Max Message Length (default: 48)
【Pro CMD: 0400040 】
Tools
Code Programming ON
Code Programming OFF
Page 44