Zennio ALLinBOX 1612 v2 User Manual page 50

Multifunction device with power supply, knx-ip interface, outputs, inputs, and logical module
Hide thumbs Also See for ALLinBOX 1612 v2:
Table of Contents

Advertisement

1475, 1513, 1551, 1589
1476, 1514, 1552, 1590
1477, 1515, 1553, 1591
1478, 1516, 1554, 1592
1479, 1517, 1555, 1593
1480, 1518, 1556, 1594
1481, 1519, 1557, 1595
1482, 1520, 1558, 1596
1483, 1521, 1559, 1597
1484, 1522, 1560, 1598
1485, 1523, 1561, 1599
1486, 1524, 1562, 1600
1487, 1525, 1563, 1601
1488, 1526, 1564, 1602
1489, 1527, 1565, 1603
1490, 1496, 1528, 1534,
1566, 1572, 1604, 1610
1491, 1497, 1529, 1535,
1567, 1573, 1605, 1611
1492, 1498, 1530, 1536,
1568, 1574, 1606, 1612
1493, 1499, 1531, 1537,
1569, 1575, 1607, 1613
1494, 1500, 1532, 1538,
1570, 1576, 1608, 1614
1495, 1501, 1533, 1539,
1571, 1577, 1609, 1615
https://www.zennio.com
2 Bytes
I
C - W - -
DPT_Value_Temp
2 Bytes
I
C - W - -
DPT_Value_Temp
1 Bit
I
C - W - -
DPT_Step
2 Bytes
I
C - W - -
DPT_Value_Tempd
2 Bytes
O
C R - T -
DPT_Value_Temp
2 Bytes
O
C R - T -
DPT_Value_Temp
2 Bytes
O
C R - T -
DPT_Value_Tempd
1 Bit
I
C - W - -
DPT_Reset
1 Bit
I
C - W - -
DPT_Reset
1 Bit
I
C - W - -
DPT_Heat_Cool
1 Bit
O
C R - T -
DPT_Heat_Cool
1 Bit
I
C - W - -
DPT_Switch
1 Bit
O
C R - T -
DPT_Switch
1 Bit
I/O
C R W - -
DPT_Switch
1 Bit
I/O
C R W - -
DPT_Switch
1 Bit
I
C - W - -
DPT_Enable
1 Bit
I
C - W - -
DPT_Enable
1 Byte
O
C R - T -
DPT_Scaling
1 Byte
O
C R - T -
DPT_Scaling
1 Byte
O
C R - T -
DPT_Scaling
1 Bit
O
C R - T -
DPT_Switch
1 Bit
O
C R - T -
DPT_Switch
1 Bit
O
C R - T -
DPT_Switch
1 Bit
O
C R - T -
DPT_Switch
1 Bit
O
C R - T -
DPT_Switch
1 Bit
O
C R - T -
DPT_Switch
1 Bit
O
C R - T -
DPT_Switch
1 Bit
O
C R - T -
DPT_Switch
2=Standby
3=Economy
4=Building
Protection
-273.00º - 670433.28º
[Tx] Setpoint
-273.00º - 670433.28º
[Tx] Basic Setpoint
0/1
[Tx] Setpoint Step
-671088.64º - 670433.28º [Tx] Setpoint Offset
-273.00º - 670433.28º
[Tx] Setpoint Status
-273.00º - 670433.28º
[Tx] Basic Setpoint Status
-671088.64º - 670433.28º [Tx] Setpoint Offset Status
0/1
[Tx] Setpoint Reset
0/1
[Tx] Offset Reset
0/1
[Tx] Mode
0/1
[Tx] Mode Status
0/1
[Tx] On/Off
0/1
[Tx] On/Off Status
0/1
[Tx] Main System (Cool)
0/1
[Tx] Main System (Heat)
[Tx] Enable/Disable Secondary
0/1
System (Cool)
[Tx] Enable/Disable Secondary
0/1
System (Heat)
0% - 100%
[Tx] [Sx] Control Variable (Cool)
0% - 100%
[Tx] [Sx] Control Variable (Heat)
0% - 100%
[Tx] [Sx] Control Variable
0/1
[Tx] [Sx] Control Variable (Cool)
0/1
[Tx] [Sx] Control Variable (Cool)
0/1
[Tx] [Sx] Control Variable (Heat)
0/1
[Tx] [Sx] Control Variable (Heat)
0/1
[Tx] [Sx] Control Variable
0/1
[Tx] [Sx] Control Variable
0/1
[Tx] [Sx] PI State (Cool)
0/1
[Tx] [Sx] PI State (Heat)
ALLinBOX 1612 v2 / 88 / 46 / Hospitality
Thermostat Setpoint Input
Reference Setpoint
0 = Decrease Setpoint; 1 =
Increase Setpoint
Float Offset Value
Current Setpoint
Current Basic Setpoint
Current Setpoint Offset
Reset Setpoint to Default
Reset Offset
0 = Cool; 1 = Heat
0 = Cool; 1 = Heat
0 = Off; 1 = On
0 = Off; 1 = On
0 = System 1; 1 = System 2
0 = System 1; 1 = System 2
0 = Disable; 1 = Enable
0 = Disable; 1 = Enable
PI Control (Continuous)
PI Control (Continuous)
PI Control (Continuous)
2-Point Control
PI Control (PWM)
2-Point Control
PI Control (PWM)
2-Point Control
PI Control (PWM)
0 = PI Signal 0%; 1 = PI Signal
Greater than 0%
0 = PI Signal 0%; 1 = PI Signal
Greater than 0%
Technical Support:
https://support.zennio.com
50

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ALLinBOX 1612 v2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Table of Contents