Zennio ALLinBOX 1612 v2 User Manual page 48

Multifunction device with power supply, knx-ip interface, outputs, inputs, and logical module
Hide thumbs Also See for ALLinBOX 1612 v2:
Table of Contents

Advertisement

1229, 1297, 1365, 1433
1230, 1298, 1366, 1434
1231, 1299, 1367, 1435
1232, 1300, 1368, 1436
1233, 1301, 1369, 1437
1234, 1302, 1370, 1438
1235, 1303, 1371, 1439
1236, 1304, 1372, 1440
1237, 1305, 1373, 1441
1238, 1306, 1374, 1442
1239, 1307, 1375, 1443
1240, 1308, 1376, 1444
1241, 1309, 1377, 1445
1242, 1310, 1378, 1446
1243, 1311, 1379, 1447
1244, 1312, 1380, 1448
1245, 1313, 1381, 1449
1246, 1314, 1382, 1450
https://www.zennio.com
1 Bit
O
C R - T -
DPT_Switch
1 Bit
I
C - W - -
DPT_Window_Door
1 Bit
I
C - W - -
DPT_Window_Door
1 Bit
I
C - W - -
DPT_Window_Door
1 Bit
I
C - W - -
DPT_Window_Door
1 Bit
I
C - W - -
DPT_Window_Door
1 Bit
I
C - W - -
DPT_Window_Door
1 Bit
I
C - W - -
DPT_Window_Door
1 Bit
I
C - W - -
DPT_Window_Door
1 Bit
I/O
C R W - -
DPT_Enable
1 Bit
I/O
C R W - -
DPT_Enable
1 Bit
I/O
C R W - -
DPT_Enable
2 Bytes I/O
C R W T U
DPT_Value_Temp
2 Bytes I/O
C R W T U
DPT_Value_Temp
1 Bit
I/O
C R W - -
DPT_Switch
2 Bytes I/O
C R W T U
DPT_Value_Tempd
1 Bit
O
C R - T -
DPT_Bool
1 Byte
O
C R - T -
DPT_Scaling
2 Bytes I/O
C R W T U
DPT_Value_Temp
2 Bytes I/O
C R W T U
DPT_Value_Temp
2 Bytes
O
C R - T -
DPT_Value_Temp
2 Bytes
I
C - W - -
DPT_Value_Humidity
2 Bytes I/O
C R W T U
DPT_Value_Humidity
2=Standby
3=Economy
4=Building
Protection
0/1
[HTx] [D] Comfort Mode Status
[HTx] [D] Window Status 1
0/1
(Input)
[HTx] [D] Window Status 1
0/1
(Input)
[HTx] [D] Window Status 2
0/1
(Input)
[HTx] [D] Window Status 2
0/1
(Input)
[HTx] [D] Window Status 3
0/1
(Input)
[HTx] [D] Window Status 3
0/1
(Input)
[HTx] [D] Window Status 4
0/1
(Input)
[HTx] [D] Window Status 4
0/1
(Input)
0/1
[HTx] [D] Enable Window Status
0/1
[HTx] [D] Thermostat Lock
0/1
[HTx] [D] Thermostat Lock
-273.00º - 670433.28º
[HTx] [D] Comfort Lower Limit
-273.00º - 670433.28º
[HTx] [D] Comfort Upper Limit
0/1
[HTx] [D] Hidden Offset On/Off
-671088.64º - 670433.28º [HTx] [D] Hidden Offset Value
0/1
[HTx] [D] Eco Mode Notification
0% - 100%
[HTx] [D] Eco Mode Ratio
[HTx] [D] Eco Mode: Lower Limit
-273.00º - 670433.28º
(Cooling)
[HTx] [D] Eco Mode: Upper Limit
-273.00º - 670433.28º
(Heating)
-273.00º - 670433.28º
[HTx] [D] Setpoint to Split
-12% - 12%
[HTx] [F] Current Humidity
[HTx] [F] High Humidity Alarm
-12% - 12%
Threshold
ALLinBOX 1612 v2 / 88 / 46 / Hospitality
0 = Off; 1 = On
0 = Closed; 1 = Open
0 = Open; 1 = Closed
0 = Closed; 1 = Open
0 = Open; 1 = Closed
0 = Closed; 1 = Open
0 = Open; 1 = Closed
0 = Closed; 1 = Open
0 = Open; 1 = Closed
0 = Disabled; 1 = Enabled
0 = Locked; 1 = Unlocked
0 = Unlocked; 1 = Locked
[-20°C, 100°C]
[-20°C, 100°C]
0 = Off; 1 = On
[-20°C, 100°C]
0 = Out of eco range; 1 =
Setpoint in Eco Range
Percentage of Time Working in Eco
Range
Lower Value for the Ecological
Range
Upper Value for the Ecological
Range
[-20°C, 100°C]
Humidity Sensor Value
Value of High Humidity Alarm
Threshold
Technical Support:
https://support.zennio.com
48