206, 235
207, 236
208, 237
209, 238
210, 239
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
https://www.zennio.com
1 Bit
I
C - W - -
DPT_Scene_AB
1 Bit
I
C - W - -
DPT_Ack
1 Bit
I
C - W - -
DPT_Ack
1 Bit
I
C - W - -
DPT_Ack
1 Bit
I
C - W - -
DPT_Ack
1 Byte
I
C - W - U
DPT_SceneControl
1 Bit
I
C - W - U
DPT_Switch
1 Bit
O
C R - T -
DPT_Switch
1 Bit
I
C - W - U
DPT_Heat_Cool
1 Bit
O
C R - T -
DPT_Heat_Cool
1 Bit
I
C - W - U
DPT_Enable
1 Bit
I
C - W - U
DPT_Enable
1 Bit
O
C R - T -
DPT_Enable
1 Bit
O
C R - T -
DPT_Enable
1 Bit
I
C - W - U
DPT_Step
1 Bit
I
C - W - U
DPT_Switch
1 Bit
I
C - W - U
DPT_Switch
1 Bit
I
C - W - U
DPT_Switch
1 Bit
I
C - W - U
DPT_Switch
1 Bit
O
C R - T -
DPT_Switch
1 Bit
O
C R - T -
DPT_Switch
1 Bit
O
C R - T -
DPT_Switch
1 Bit
O
C R - T -
DPT_Switch
1 Byte
I
C - W - U
DPT_Fan_Stage
1 Byte
I
C - W - U
DPT_Fan_Stage
1 Byte
I
C - W - U
DPT_Fan_Stage
1 Byte
O
C R - T -
DPT_Fan_Stage
1 Byte
O
C R - T -
DPT_Fan_Stage
0/1
[Cx] Move (Reversed)
0/1
[Cx] Direct Positioning 1
0/1
[Cx] Direct Positioning 2
0/1
[Cx] Direct Positioning 1 (Save)
0/1
[Cx] Direct Positioning 2 (Save)
0-63; 128-191
[Fan Coil] Scenes
0/1
[FCx] On/Off
0/1
[FCx] On/Off (Status)
0/1
[FCx] Mode
0/1
[FCx] Mode (Status)
0/1
[FCx] Fan: Manual/Automatic
0/1
[FCx] Fan: Manual/Automatic
[FCx] Fan: Manual/Automatic
0/1
(Status)
[FCx] Fan: Manual/Automatic
0/1
(Status)
0/1
[FCx] Manual Fan: Step Control
0/1
[FCx] Manual Fan: Speed 0
0/1
[FCx] Manual Fan: Speed 1
0/1
[FCx] Manual Fan: Speed 2
0/1
[FCx] Manual Fan: Speed 3
0/1
[FCx] Fan: Speed 0 (Status)
0/1
[FCx] Fan: Speed 1 (Status)
0/1
[FCx] Fan: Speed 2 (Status)
0/1
[FCx] Fan: Speed 3 (Status)
[FCx] Manual Fan: Enumeration
0 - 255
Control
[FCx] Manual Fan: Enumeration
0 - 255
Control
[FCx] Manual Fan: Enumeration
0 - 255
Control
[FCx] Fan: Speed Enumeration
0 - 255
(Status)
[FCx] Fan: Speed Enumeration
0 - 255
(Status)
ALLinBOX 1612 v2 / 88 / 46 / Hospitality
0=Lower; 1=Raise
0 = No Action; 1 = Go to Position
0 = No Action; 1 = Go to Position
0 = No Action; 1 = Save Current
Position
0 = No Action; 1 = Save Current
Position
0 - 63 (Execute 1 - 64); 128 - 191
(Save 1 - 64)
0 = Off; 1 = On
0 = Off; 1 = On
0 = Cool; 1 = Heat
0 = Cool; 1 = Heat
0 = Automatic; 1 = Manual
0 = Manual; 1 = Automatic
0 = Automatic; 1 = Manual
0 = Manual; 1 = Automatic
0 = Down; 1 = Up
0 = Off; 1 = On
0 = Off; 1 = On
0 = Off; 1 = On
0 = Off; 1 = On
0 = Off; 1 = On
0 = Off; 1 = On
0 = Off; 1 = On
0 = Off; 1 = On
S0 = 0; S1 = 1; S2 = 2; S3 = 3
S0 = 0; S1 = 1; S2 = 2
S0 = 0; S1 = 1
S0 = 0; S1 = 1; S2 = 2; S3 = 3
S0 = 0; S1 = 1; S2 = 2
Technical Support:
https://support.zennio.com
38

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ALLinBOX 1612 v2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Table of Contents