This message is for the use case when an implementation has detected a Processor Failed - IERR
Condition.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - CPU
SNMP Trap ID: 40
CIM Prefix: PLAT CIM ID: 0042
User Action:
Information only; no action is required
• FQXSPPU0004M: [ProcessorElementName] has Failed with FRB1/BIST condition.
This message is for the use case when an implementation has detected a Processor Failed - FRB1/BIST
condition.
Severity: Error
Serviceable: Yes
Automatically notify Support: Yes
Alert Category: Critical - CPU
SNMP Trap ID: 40
CIM Prefix: PLAT CIM ID: 0044
User Action:
Please check event log in xClarity Controller (XCC) Web GUI to identify the power supply unit or flahs
power module failure. Check system spec and replace the power supply unit or flash power module to the
same specification.
• FQXSPPU0005M: [ProcessorElementName] has Failed with FRB2/POST condition.
This message is for the use case when an implementation has detected a Processor Failed - FRB2/POST
condition.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - CPU
SNMP Trap ID: 40
CIM Prefix: PLAT CIM ID: 0046
User Action:
Please check event log in xClarity Controller (XCC) Web GUI to identify the power supply unit failure
• FQXSPPU0006M: [ProcessorElementName] has Failed.
This message is for the use case when an implementation has detected a Processor Failed - FRB3
condition.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - CPU
SNMP Trap ID: 40
CIM Prefix: PLAT CIM ID: 0048
User Action: